Page 12 of 24
803341NZ - HydroTap Taps Install Instructions 09.18 v2.11
Position the tap such that it dispenses into the sink bowl
with ample clearance for a cup or tea pot.
Cut a 35mm hole in the bench / sink top.
SINK TOP
35mm
BRAIDED HOSE x 3
White/No colour:
External mains water supply
Red band: Mixer OUT
Blue band: Mixer IN
3 - Mixer Tap
CLASSIC, ARC, CUBE
3.2
•
Fit the O-ring into the recess on the underside of the
Mixer tap. If mounting on an uneven surface, apply a
light smear of silicone sealant to the O-ring, to ensure a
watertight seal.
•
Pass the tap tubes and threaded extension through the
35mm hole and position the tap so that it discharges into
the sink.
•
Fit the lower rubber washer to the threaded extension.
•
Secure the tap in position with the metal washer and nut.
•
Affix the three hoses to the tap. Match the hose colours
to the coloured bands on the copper extension tubes.
Arc Mixer Tap
For use with
Classic or Arc HydroTap
NOTE:
For low pressure installations
Replace the normal 804178-Aerator with an
805734-flow straightener in the spout of a vented
Zenith mixer tap.
3.1
Classic Vented
Mixer Tap
For use with
Classic/Arc/Cube HydroTap
Cube Mixer Tap
For use with
Classic or Cube HydroTap
O-RING
LOWER
RUBBER
WASHER
METAL WASHER
NUT
804178
805734