background image

803341NZ - HydroTap Taps Install Instructions 09.18 v2.11  

Page 1 of 24

Installation Instructions

®

Zenith HydroTap Taps

HydroTap Classic

HydroTap Elite

HydroTap Arc/Cube

Classic All-In-One

Celsius All-In-One

Celsius Arc/Cube

Mixer Classic/Arc/Cube

Содержание HydroTap Classic

Страница 1: ...Install Instructions 09 18 v2 11 Page 1 of 24 Installation Instructions Zenith HydroTap Taps HydroTap Classic HydroTap Elite HydroTap Arc Cube Classic All In One Celsius All In One Celsius Arc Cube M...

Страница 2: ...Page 2 of 24 803341NZ HydroTap Taps Install Instructions 09 18 v2 11 Notes...

Страница 3: ...ydroTap Taps Install Instructions 09 18 v2 11 Page 3 of 24 1 HydroTap Classic Elite 6 2 HydroTap Arc Cube 8 3 Mixer Tap 12 4 Classic All In One Tap 14 5 Celsius All In One Tap 18 6 Celsius Arc Cube 21...

Страница 4: ...Cube are standalone taps compatible with the HydroTap undersink unit offering instant boiling chilled and or sparkling water Classic Arc and Cube Mixer Tap range may be used in conjunction with the st...

Страница 5: ...are provided for the installation of HydroTap taps only This book must be read in conjunction with the undersink HydroTap Installation Manual and the User Manual For new installations it is recommend...

Страница 6: ...washer is formed similarly to a spring washer It will flatten once the assembly is tightened Note feed each of the three tubes and USB cable evenly in between the legs of the spider clamp Note If the...

Страница 7: ...e to Vent 1 3 Typical HydroTap Installation RED CLEAR BLUE BRAIDED USB CHILLED OUTLET MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT Note All silicon tubes must be cut to size They...

Страница 8: ...les are required for the new spout height and orientation check the new plastic clip position will clear the undercut and that the wiring loom will not be pinched when assembled 4 Slide the plastic cl...

Страница 9: ...rol Right Hand Control B C C B 50mm 2 2 Height adjustment Fixed position options O RING LOWER RUBBER WASHER METAL WASHER NUT 2 4 Mounting Cut a 35mm hole in the bench sink top BENCH TOP 35mm NOTE To r...

Страница 10: ...Sparkling Used with BCS only Type B Chilled Type A Boiling Type D Sparkling Type E Chilled Ambient Red Silicon Blue Silicon Blue White LLDPE White LLDPE Blue LLDPE Type F S S Tube Three way silicon tu...

Страница 11: ...1 Area 2 BOILING CHILLED SPARKLING BOILING CHILLED BOILING AMBIENT BOILING CHILLED SPARKLING CHILLED Pre cut edge on backing paper Outer edge Outer edge 2 6 Attach Label Working from inside the cupbo...

Страница 12: ...ight seal Pass the tap tubes and threaded extension through the 35mm hole and position the tap so that it discharges into the sink Fit the lower rubber washer to the threaded extension Secure the tap...

Страница 13: ...e BOILING OUT BYPASS IN VENT BYPASS OUT Note Mains hose length is 750mm Plug and cord length is 1800mm Position the under sink unit close to the outlet tap within reach of the hose and cord lengths su...

Страница 14: ...nd position the tap so that it discharges into the sink Thread the cable and silicon tubes through the circular clamp block see figures 4 3 4 5 and fix with nut Affix the braided hoses see figures 4 4...

Страница 15: ...he hoses are lubricated prior to assembly Check the correct position for Hot and Cold connections by matching the colours on the braided hoses with the coloured markings on the copper extension tubes...

Страница 16: ...connection Mains IN To Mixer IN R R C B B Vented Mains Assembled Clamp Block Note If the flow rate is too fast a teflon flow restrictor is provided with the tap Cut the red silicon tube 75mm minimum f...

Страница 17: ...connector strainer supplied Booster RED CLEAR BLUE BRAIDED USB CHILLED OUTLET MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT Note Mains hose length is 750mm Plug and cord length is...

Страница 18: ...steel washer and large nut from inside the cupboard space Connect silicon hoses to the 3 way tube as shown in Fig 5 3 5 4 Affix the braided hoses for hot and cold mains water supply For Celsius A I O...

Страница 19: ...G 5 4 FROM STEAM VENT OUTLET OF UNDERSINK UNIT 3 WAYS MULTI CHANNEL BOTTOM END OF 3 WAY TUBE 3 STAINLESS STEEL TUBES STEAM VENT BOILING OUTLET CHILLED OUTLET BRASS NUT USB PLUG COLD MAINS HOT MAINS JG...

Страница 20: ...e and connector strainer supplied Booster RED CLEAR BLUE BRAIDED USB CHILLED OUTLET MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT Note Mains hose length is 750mm Plug and cord leng...

Страница 21: ...punch for sink tops not supplied 35mm diameter hole saw for timber bench tops not supplied 42mm AF tube spanner or wrench not supplied for fixing tap assembly 6 Celsius Arc Cube BENCH TOP 35mm 35mm ho...

Страница 22: ...ng model Vent outlet 6 2 Connect the Chilled Tube from the tap via the Y Connector to the Chilled and Spar kling tubes to the undersink unit Pass all the hoses tubes and USB lead through the 35mm hole...

Страница 23: ...connector strainer supplied RED CLEAR BRAIDED USB MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT Note Mains hose length is 750mm Plug and cord length is 1800mm Position the under si...

Страница 24: ...0800 558 055 As Zenith policy is one of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may not be true represe...

Отзывы: