8.1 Maintenance
During normal operation your 13K2 amplifier will provide trouble-free service. The only user maintenance required
is to periodically vacuum clean the foam dust-filters behind the front grille.
In some extreme cases it may be necessary for authorized service personnel to clean the inside of the amplifier.
These conditions usually occur after prolonged use in extreme environments such as those using cracked oil,
smoke machines. If you are using y our amplifier in a heavy-duty application, it is recommended to have your
amplifier serviced at regular intervals purely as a preventative action.
9 TECHNICAL SPECIFICATIONS
Following are the 13K2 technical specifications. These figures are accurate at the time of printing but please note
that all figures are subject to change without notice. For the most accurate and current information available,
please visit
www.prolight.co.uk
The Zenith amplifier range has been designed and engineered to work in demanding environments including
installation and touring with military endurance. Oversized multi-speed fans and large heat sinks improve heat
dissipation, while the SMPSU optimises the amplifiers efficiency while reducing the weight. The 10K4 and 13K2
lightweight power amplifiers from Zenith feature high efficiency TD class technology for high power output to
weight ratio, and are housed within compact 2U chassis. With up to 6500W per channel these power amplifiers
are ideal for rental or large installations. Suitable for driving into 2
Ω
loads, the amplifiers are equipped with an
extensive set of protection circuits for reliable operation.
-
2 x 2300W RMS @ 8
Ω
-
2 x 4400W RMS @ 4
Ω
-
2 x 6500W RMS @ 2
Ω
-
1 x Bridge 8800W RMS @ 8
Ω
-
1 x Bridge 13,000W RMS @ 4
Ω
-
Performance with gain 35dB, VPL: 195V
-
VPL selectable per channel 195, 170, 140, 116, 100, 80, 66, 54V
-
VPL selectable when bridged 390, 340, 280, 232, 200, 160, 132, 108V
-
Voltage peak limiter mode (per channel) hard/soft
-
Amplifier gain selectable (all channels) 23, 26, 29, 32, 35, 38, 41, 44dB (default gain 35dB)
-
Level adjustment (per channel): front-panel potentiometer, detented from
∞
to 0dB
-
Input connectors (per channel): 3-pin XLR, electronically balanced
-
Output connectors (per channel): Neutrik speakON
-
Output bridge mode per two channel’s A and B bridge, A as the input source
-
Cooling system: Three fans, airflow design from the front to the rear for temperature control
-
Status indication: Signal present/high-impedance: -20dB,-15dB, -10dB and -4dB output signal, Voltage
Peak Limiter (VPL), Current Peak Limiter (CPL), Very High Frequency (VHF), high temperature, fault, mute
-
Power average limiter
-
Protection circuits: Soft start, Voltage Peak Limiter (VPL), Current Peak Limiter (CPL), Very High Frequency
(VHF), high temperature and load fault
-
Inrush current draw: 5A max.
-
Dimensions: 88 x 483 x 425mm
-
Weight: 13kg
Note 1: Automatic -6dB gain compensation when bridging channels.
Note 2: PAL can reduce the maximum output power to keep the power supply operating safely, and/or to prevent
excessive current draw tripping the mains breaker.
Note 3: The amplifier will be fully operational at bridge mode 2
Ω
loads, but due to physical constraints in the
construction, the max. output power will not be significantly higher than running individual channels and therefore