background image

9. WARRANTY

    

The meter is warranted to be free from 

    defects in material and workmanship 
    for a period of one year from the date 
    of purchase. This warranty covers 
    normal operation and does not cover 
    battery, misuse, abuse, alteration, 
    tampering, neglect, improper 
    maintenance, or damage resulting from
    leaking batteries. Proof of purchase is 
    required for warranty repairs. Warranty 
    is void if the meter has been opened. 

11. CE CERTIFICATION

    

The  meter  conforms  to  the  following  

    standards:
 * E

 N 61326:1997/A1:1998

 * EN 55011:1998/A1:2000 (Group 1, 
                                             Class B)
 * IEC 61000-4-2:1995/A1:1998/A2:2000
 * IEC 61000-4-3:1995/A1:1998/A2:2000  
    ,  t he m

  eter c omplies w

  ith t he essential  

    protection  requirements  of   Council  
       Directive  89/336/EEC  on  the    a
      pproximation  of  the  laws  of  the  Member  
   States relating to electromagnetic 
   compatibility.

10.RETURN AUTHORIZATION

    

Authorization must be obtained from 

    the supplier before returning items for 
    any reason. When requiring a RA 
   (Return Authorization), please include 
   data regarding the defective reason, 
   the meters are to be returned along with 
   good packing to prevent any damage in 
   shipment and insured against possible 
   damage or loss.

Содержание 8888

Страница 1: ...MINI INFRARED THERMOMETER Model 8888 8889 8890 INSTRUCTION MANUAL...

Страница 2: ...d operation time saving to get temperature measurement Be sure the measured object fills the spot seen by the aperture There will be a delay of approximately one second between the time you initially...

Страница 3: ...ined for hundreds of feet Be careful not to let the beam on a reflective surface strike your eyes Do not allow the laser light beam impinge on any gas which can explode 2 FRONT PANEL DESCRIPTION 1 Las...

Страница 4: ...o 0 1 C 0 1 F 40 100 C others 1 0 o C Selectable 0 85 0 90 0 95 0 95 Model 8888 8889 Temp range o 20 260 C o 40 500 C Distance Ratio 10 1 Resolution o 1 C Emissivity 0 95 Function Buttons 6 1 3 or 3...

Страница 5: ...V battery Operating Current Max 40mA Weight 140g 4 5 oz Size 5 6 x 1 4 x 1 3 170 x 44 x 40 mm Accuracy notes Accuracy specified is for operating in ambient temperature 4 INDICATOR 1 Digital readout 2...

Страница 6: ...and holding the trigger then press the C F key until the desired units is shown on the LCD C Data Hold This meter automatically holds the last temperature reading on the LCD for 6 seconds after the t...

Страница 7: ...djust to wide ambient temp changes When low temperatures are to be measured followed a high temperature measurements several minutes recovering time is required after the high and before the low tempe...

Страница 8: ...limit 8 MAINTENANCE Case cleaning Use caution with a damp cloth to clean the exterior housing ensure no water or soap is allowed inside the meter and on the infrared lens Lens cleaning WARNING Recomm...

Страница 9: ...andards EN 61326 1997 A1 1998 EN 55011 1998 A1 2000 Group 1 Class B IEC 61000 4 2 1995 A1 1998 A2 2000 IEC 61000 4 3 1995 A1 1998 A2 2000 the meter complies with the essential protection requirements...

Страница 10: ...meter Sound Level Meter Air Flow meter Infrared Thermometer K type Thermometer K J T type Thermometer K J T R S E type Thermometer pH Meter Conductivity Meter T D S Meter D O Meter Saccharimeter Manom...

Отзывы: