6.1 

Electrical Specifications

Built-in system amplifier

Operating voltage (C7 battery): 

 

39 – 20 VDC

Operating voltage (external supply): 

24 VDC

Frequency range (-3dB):   

 

180 – 4500 Hz

S/N ratio:   

 

 

 

<

 -55 dB

TDH-N:   

 

 

 

<

 1%

Amplifier input impedance: 

 

Z = 213 ohm @ 1 kHz

 

   

 

 

 

 

Z = 180 ohm @ 250 Hz

 

   

 

 

 

 

(R = 52 ohm)

Microphone signal level:   

 

5 - 10 mV

Microphone impedance:   

 

135 ohm @ 1 kHz

Amplifier output impedance: 

 

Z =  92 ohm @ 1 kHz

 

   

 

 

 

 

Z =  60 ohm @ 250 Hz

 

   

 

 

 

 

(R = 1.5 ohm)

Speaker signal level: 

 

 

0.7 V

Speaker impedance: 

 

 

135 ohm @ 1 kHz

Compass safety distance:   

 

155 cm

6.2 

Certificates

The system components have a light, robust and corrosion resistant 

construction, and conform to the following Product Specifications:

 

● IEC 533, 2

nd

 edition, June 1996; 

 

«EMC of Electrical and Electronic Installation in Ships and of Mobile 

and Fixed Offshore Units»

 

● Det Norske Veritas (DNV), Certification Notes no. 2.4; 

 

«Environment test Specification for Instrumentation and Automation 

Equipment»

Optional EMC requirements

 

● IEC 945, February 1995; 

 

«Maritime navigation and Radio Equipment and Systems - general 

requirements, methods of testing and required test results».

CENELEC

 

● EN50081-1 January 1992; 

 

«Generic emission standard, Part 1: Residential, commercial and 

light industry»

 

● EN50082-2 March 1995; 

 

«Generic immunity standard, Part 2: Industrial environment»

Test reference:

Report No.: 

 

96-1196

 

Issued by:  

 

DET NORSKE VERITAS AS

 

Report No.: 

 

S97 0662a and S97 0662b

 

Issued  by:  

 

Jydske EMC Lab A/S, Denmark

Содержание Vingtor Stentofon VSP 12-Way

Страница 1: ...Amplified BatterylessTelephone System VSP 12 Way A100K10873 TECHNICAL MANUAL...

Страница 2: ...3006200024 Main Station panel mounted indoor unit VSP 213 L 1020600935 Publication Log Rev Date Author Comments 4 0 2008 04 23 Published 5 0 2009 08 24 SEN JF New circuit board Some contents updates...

Страница 3: ...Setting Extension Number 10 4 Operation 11 5 Troubleshooting 12 5 1 Conversation Lines 12 5 2 Call Tone 12 6 Specifications 13 6 1 Electrical Specifications 13 6 2 Certificates 13 7 DIP Switch Settin...

Страница 4: ...ndependent of the vessel s power supply and fulfills the demands for emergency communication between vital locations onboard The VSP system described in this manual is a system comprising up to 12 mai...

Страница 5: ...for weelhouse and control room VSP 223 L Main Station panel mounted with relay Alarm stop button Noise compensated microphone LED call indicator Bulkhead mount in on wall back box MBOKS Suitable for c...

Страница 6: ...the board with the old inductor When a call is being made the actual line will carry a generated voltage This voltage is fed through the active line via the corresponding diode D11 and D12 to the amp...

Страница 7: ...alling tone frequency is 2500 Hz It is not recommended to change the call tone frequency because it is adjusted to the mechanical resonance of the handset The call tone has a fluttering frequency at a...

Страница 8: ...latch relay circuit for activating external audible and or visible signal units Additional terminals 17 22 are added for this feature Local 24 VDC for signal unit 17 24 V and 20 0 V Signal unit connec...

Страница 9: ...1 2 3 4 5 6 7 8 9 10111213141516 1 2 3 4 5 6 7 8 9 10111213141516 1 2 3 4 5 6 7 8 9 10111213141516 1 2 3 4 5 6 7 8 9 10111213141516 17 18 19 20 21 22 17 18 19 20 21 22 17 18 19 20 21 22 2 X 33 32 31...

Страница 10: ...mber 1 Insert jumpers into pins J2 and J3 2 Activate the DIP switch on the PCB corresponding to the selected number by sliding it to the ON position Figure 4 DIP switch setting for extension no 2 For...

Страница 11: ...er and without distortion for a guaranteed period of 20 minutes After 20 minutes the conversation period can be extended by turning the crank again By calling a station with a built in relay circuit f...

Страница 12: ...der 5 2 Call Tone Extension numbers 11 and 12 do not work No call tone Jumpers on pins J2 and J3 are not inserted Insert jumpers on pins J2 and J3 located on the right side of the DIP switch Station r...

Страница 13: ...ust and corrosion resistant construction and conform to the following Product Specifications IEC 533 2nd edition June 1996 EMC of Electrical and Electronic Installation in Ships and of Mobile and Fixe...

Страница 14: ...9 Issued by China Classification Society Certificate no 16 LD1543066 PDA Valid until 2021 07 12 Issued by ABS American Bureau of Shipping Certificate no 11080100 Valid until 2019 08 13 Issued by Russ...

Страница 15: ...ension No 6 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7 6 8 10 11 12 J2 J3 Extension No 7 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7 6 8 10 11 12 J2 J3 Extension No 8 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7...

Страница 16: ...16 A100K10873 VSP 12 Way Batteryless Telephone System Technical Manual 8 Station Mounting Dimensions 8 1 VSP 122...

Страница 17: ...17 VSP 12 Way Batteryless Telephone System Technical Manual A100K10873 8 2 VSP 122P...

Страница 18: ...18 A100K10873 VSP 12 Way Batteryless Telephone System Technical Manual 8 3 VSP 211 L 8 4 VSP 213 L...

Страница 19: ...19 VSP 12 Way Batteryless Telephone System Technical Manual A100K10873 8 5 VSP 223 L...

Страница 20: ...part or in whole must include this legend Zenitel All rights reserved customer service zenitel com DOC NO A100K10873 The WEEE Directive does not legislate that Zenitel as a producer shall collect end...

Отзывы: