background image

SafeLine

 

TTR

Installation manual

 ENGLISH  v.1.01
05.2012

PATENT PENDING

Emergency telephone for lifts. Complies to EN81-28 and 
EN81-70 standards.

Summary of Contents for TTR

Page 1: ...SafeLine TTR Installation manual ENGLISH v 1 01 05 2012 PATENT PENDING Emergency telephone for lifts Complies to EN81 28 and EN81 70 standards...

Page 2: ...8 Ah Charge 13 7 13 9 V max 200 mA Emergency light Emergency light output 12V max 0 5A Acoustic emergency signal output 12 VDC max 0 5A Inputs 10 30 Volts 5 mA Optically isolated Pictogram outputs Max...

Page 3: ...station card 12 Wiring diagram PSTN LINE Max 9 units 12 Activating the SIM card 13 LED indication SafeLine TTR Front panel 14 LED indication Pictograms 15 Test procedure after installation 16 Configu...

Page 4: ...Claims under warranty are likewise excluded in such cases The technical data is the latest available The manufacturer accepts no liability arising from printing errors mistakes and changes Safety Pre...

Page 5: ...t by the jumpers on the TTR board not autodetect Install jumpers on the TTR board so they stand as the unit which is replaced same jumper names Remember to attach the unit and tighten the screws in th...

Page 6: ...tive alarm Battery status c PSTN GSM Net Call status 4 rS232 Pc connection For firmware update and configuration 5 Slot for optional extra station card Two supplementary microphone speaker units can b...

Page 7: ...y call to alarm operator Installation ENGLISH v 1 01 extra station card PSTn card GSm card 1 Terminal or rJ12 connector for PSTn line Internal connection of PSTN line 2 GSm antenna connection Sma Fixe...

Page 8: ...44553 1000 6E 44553 1000 6E 44553 44553 44553 1000 6E 44553 1000 6E 045 100 16E 045 100 16E GSm PSTn Installation ENGLISH v 1 01 mounting interface boards mounTinG Unplug the main power and battery b...

Page 9: ...NE LINE PSTN PHONE LINE PSTN NOT USED EMG BUTTON EMG BUTTON INPUT 1 LMS INPUT 2 LMS GROUND NOT USED 12 V DC IN EMG BELL OUT EMG LIGHT EMG LIGHT PoWer SuPPly 12 V dc Jumper settings With the jumpers J8...

Page 10: ...and PicToGramS NOT USED PHONE LINE PSTN PHONE LINE PSTN NOT USED EMG BUTTON EMG BUTTON INPUT 1 LMS INPUT 2 LMS GROUND NOT USED 12 V DC IN YELLOW PICT GREEN PICT PoWer SuPPly 12 V dc EMG BELL OUT With...

Page 11: ...on as shown left the SafeLine TTR can sypply backup power for emergency light in the lift car The SafeLine TTR can also operate pictograms according to EN 81 28 EN 81 70 The jumpers J1 J2 and J5 shall...

Page 12: ...100 16E 045 100 16E Installation ENGLISH v 1 01 WirinG diaGram PSTn line maX 9 uniTS Connect the telephone line in parallel according to the picture above It s possible to connect up to 9 SafeLine TT...

Page 13: ...for setting up a new PIN code The randomly chosen PIN code is memorized by the unit If you want to upload a new SIM card with PIN code 1111 you will need to first upload a SIM card with PIN code 1234...

Page 14: ...reset led 3 indicates the phone line s status continuous red No SIM card when using GSM flashing red No telephone line connected Searching for GSM network flashing green Telephone line connected GSM n...

Page 15: ...s The Yellow Pictogram LED is lit as soon as the alarm button is pressed Strictly EN81 70 88 1 Green LED Call connected The Green pictogram LED turns on as soon as the SafeLine unit detects a respondi...

Page 16: ...n the speaker LED 1 turns green LED 3 ashes green Connect a telephone to the RJ12 connector on the front of the SafeLine All LEDs are off No tone No reaction No tone LED 3 ashes red 5 times Long tone...

Page 17: ...allation The configuration software SafeLine Pro can be downloaded from www safeline eu The configuration cable is provided by SafeLine remote configuration with telephone For remote configuration you...

Page 18: ...entered Dial the phone number of the units phone or GSM subscription If there is only one unit connected the unit answers with 3 long tones If there are multiple units connected the unit answers with...

Page 19: ...eP No Remote configuration with external telephone 2 short beeps waiting for PIN code Valid PIN code Dial to enter configuration mode Enter the PIN code Yes No Yes Yes 2 short beeps entering config mo...

Page 20: ...and wait for dial tone Dial to enter configuration mode 2 short beeps entering config mode Continue configure 2 short beeps Invalid input one long tone Last code has to be reentered Call disconnected...

Page 21: ...use the factory reset command 99 1 Safeline auTodialerS uniTS ProGramminG eXamPle 1 Start programming 2 Enter P100 ID code 3 Set test alarm type 4 Set number of days between test alarm 5 LMS phone num...

Page 22: ...fault 2 Q23 3 CPC Change this only if your alarm operator is using any of the mentioned protocols Call type 2nd number 22 Call type 3rd number 23 Call type 4th number 24 Call type LMS number 30 LMS Li...

Page 23: ...recorded message Options for the recorded message from lift car 62 0 Disable recorded message 1 Enables recorded message 62 Play the the recorded message Options for the recorded message from top of...

Page 24: ...e activated when set delay reached Relay 1 will be deactivated when the reset button is pressed Change password 91 Change password default 0000 Simulate an alarm event 94 Triggers an alarm event after...

Page 25: ...Making calls like with a normal fixed line phone also GSM 3 Emergency calls to pre programmed numbers at the press of the alarm button 4 Receiving incoming calls 5 Test alarms at preset intervals 6 S...

Page 26: ...ted by law 0 0 3 2 1 0 8 5 2 1 7 4 0 9 6 3 Operating ENGLISH v 1 01 Intercom machine room to car pit Top of car Press 0 to dial external telephone number Press 1 to call the lift car Press 2 to call t...

Page 27: ...ProceSS Alarm operator made connection Calling 1st phone number Calling 2nd phone number Calling 3rd phone number Calling 4th phone number Wait 1 minute Line missing or busy Max 12 calls Emergency ala...

Page 28: ...ult settings Battery test If the reset button is pressed 3 times within 2 seconds a battery test will be performed The battery test takes about 20 minutes If the battery is low the test will be cancel...

Page 29: ...ty Volume might be set too loud Lower the volume and check again Interfering noise when the call is connected If the main unit is installed on the car roof the problem might be due to induction in the...

Page 30: ...for assistance For more information about our distrubutors refer to www safeline eu all returns must be sent well packed For more information about repairs refer to www safeline eu or contact Mikael B...

Page 31: ...31 2012 SafeLine and all the SafeLine products and accessories are copyrighted by law Service ENGLISH v 1 01...

Page 32: ...0 2 762 97 10 E mail order safeline eu SafeLine Deutschland Westfalenstra e 22a D 51688 Wipperf rth DEUTSCHLAND Tel 49 0 2267 8 67 96 63 E mail order safeline eu SafeLine Denmark Erhvervsvej 19 2600 G...

Reviews: