background image

10

A100K10873

VSP 12-Way Batteryless Telephone System

Technical Manual

3.3  Compass Safety

The station units must be installed at least 155 cm away from the 

vessel’s magnetic compass. 

3.4  Setting Extension Number

Each VSP station must have its own extension number, 1 to 12, set by 

DIP switches.
To set the extension number:

1.  Insert jumpers into pins J2 and J3.
2. 

Activate the DIP switch on the PCB corresponding to the selected 

number by sliding it to the ON position.

Figure 4: DIP switch setting for extension no. 2

For information on all extension number settings, see section

 7 DIP 

Switch Settings for Extension Numbers

.

A label strip with numbers 1 to 12 is shipped with each station.

 

● Fix the label with the relevant extension number in the frame next to 

the text 

Station no

 at the front of the station.

Figure 5: 

Extension number label

Содержание Vingtor Stentofon VSP 12-Way

Страница 1: ...Amplified BatterylessTelephone System VSP 12 Way A100K10873 TECHNICAL MANUAL...

Страница 2: ...3006200024 Main Station panel mounted indoor unit VSP 213 L 1020600935 Publication Log Rev Date Author Comments 4 0 2008 04 23 Published 5 0 2009 08 24 SEN JF New circuit board Some contents updates...

Страница 3: ...Setting Extension Number 10 4 Operation 11 5 Troubleshooting 12 5 1 Conversation Lines 12 5 2 Call Tone 12 6 Specifications 13 6 1 Electrical Specifications 13 6 2 Certificates 13 7 DIP Switch Settin...

Страница 4: ...ndependent of the vessel s power supply and fulfills the demands for emergency communication between vital locations onboard The VSP system described in this manual is a system comprising up to 12 mai...

Страница 5: ...for weelhouse and control room VSP 223 L Main Station panel mounted with relay Alarm stop button Noise compensated microphone LED call indicator Bulkhead mount in on wall back box MBOKS Suitable for c...

Страница 6: ...the board with the old inductor When a call is being made the actual line will carry a generated voltage This voltage is fed through the active line via the corresponding diode D11 and D12 to the amp...

Страница 7: ...alling tone frequency is 2500 Hz It is not recommended to change the call tone frequency because it is adjusted to the mechanical resonance of the handset The call tone has a fluttering frequency at a...

Страница 8: ...latch relay circuit for activating external audible and or visible signal units Additional terminals 17 22 are added for this feature Local 24 VDC for signal unit 17 24 V and 20 0 V Signal unit connec...

Страница 9: ...1 2 3 4 5 6 7 8 9 10111213141516 1 2 3 4 5 6 7 8 9 10111213141516 1 2 3 4 5 6 7 8 9 10111213141516 1 2 3 4 5 6 7 8 9 10111213141516 17 18 19 20 21 22 17 18 19 20 21 22 17 18 19 20 21 22 2 X 33 32 31...

Страница 10: ...mber 1 Insert jumpers into pins J2 and J3 2 Activate the DIP switch on the PCB corresponding to the selected number by sliding it to the ON position Figure 4 DIP switch setting for extension no 2 For...

Страница 11: ...er and without distortion for a guaranteed period of 20 minutes After 20 minutes the conversation period can be extended by turning the crank again By calling a station with a built in relay circuit f...

Страница 12: ...der 5 2 Call Tone Extension numbers 11 and 12 do not work No call tone Jumpers on pins J2 and J3 are not inserted Insert jumpers on pins J2 and J3 located on the right side of the DIP switch Station r...

Страница 13: ...ust and corrosion resistant construction and conform to the following Product Specifications IEC 533 2nd edition June 1996 EMC of Electrical and Electronic Installation in Ships and of Mobile and Fixe...

Страница 14: ...9 Issued by China Classification Society Certificate no 16 LD1543066 PDA Valid until 2021 07 12 Issued by ABS American Bureau of Shipping Certificate no 11080100 Valid until 2019 08 13 Issued by Russ...

Страница 15: ...ension No 6 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7 6 8 10 11 12 J2 J3 Extension No 7 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7 6 8 10 11 12 J2 J3 Extension No 8 OFF ON 9 1 DIP SWITCH SETTING 2 3 4 5 7...

Страница 16: ...16 A100K10873 VSP 12 Way Batteryless Telephone System Technical Manual 8 Station Mounting Dimensions 8 1 VSP 122...

Страница 17: ...17 VSP 12 Way Batteryless Telephone System Technical Manual A100K10873 8 2 VSP 122P...

Страница 18: ...18 A100K10873 VSP 12 Way Batteryless Telephone System Technical Manual 8 3 VSP 211 L 8 4 VSP 213 L...

Страница 19: ...19 VSP 12 Way Batteryless Telephone System Technical Manual A100K10873 8 5 VSP 223 L...

Страница 20: ...part or in whole must include this legend Zenitel All rights reserved customer service zenitel com DOC NO A100K10873 The WEEE Directive does not legislate that Zenitel as a producer shall collect end...

Отзывы: