10
11
Mount the
TA-33
Backbox onto the wall using A4 socket
head screws
Plug the Ethernet cable into
LAN port
on the station. If the switch
does not support PoE, a
24VDC Power Supply
can be connected
to the stations
Power Input
.
Mount the Turbine station onto the back box with the M5
fasteners provided. Apply 5 Nm torque.
1
2
3
1
2
3
To ensure the IP-66 rating, use the grommets and M20
cable gland provided for the cable holes on the back
box.
On-wall mounting
For mounting the Turbine Extenden on the
wall, use the
TA-33
Turbine Extended On-
wall Backbox.
• Mounting holes are to be drilled as
shown in the figure.
• Max. recommended screw diameter:
ISO M6 or ANSI 1/4”.
• Screw length must be greater than 25
mm or 1”.
• A4 stainless steel socket head
screws/bolts are recommended. Max.
screw head diameter: 9.5 mm or 3/8”.
76
27
5
Ø 20
61
120
30
5
25
Ø 6,5
Ø 9,5