Electrical Connections

8 Mounting Cable Gland 

Remove two blind plugs and insert one 

M16 Ex e and one M25 Ex e cable gland. 

Make sure to tighten sufficiently to attain 

IP-66 rating for watertightness, but be 

aware of plastic material limitations.

Related Documentation

Document No.

Documentation

A100K12133

Exigo & Turbine Ex Maintenance Procedures

A100K11460

Exigo Technical Manual

A100K11958

Flowire Installation & Configuration Manual

A100K11471

Exigo User Manual

A100K11194

Turbine Stations Configuration Manual

Accessories & Spare Parts

Item Number

Item Name

Item Description

AK5850HS

AK5850HS

Ex-Approved Headset with plug

1008150025

TAX-2B

Ex-Approved Cable for Headset with PTT Button

1008150030

TAX-3

Ex-Approved Handset with PTT, unterminated

1023533511

EMMAX-1H

Exigo Handheld Industrial Ex Microphone

1000150040

TAX-4

Cable gland kit (10x) for TFIX and EAPFX

1023594100

EGA-1

Button Protection Covers (10x)

1008140250

TA-25

M6 screw kit

Specific Conditions of Use:

•  The Ex Products and associated cable glands are tested for low risk 

of mechanical hazard and shall be protected against higher impact 

energy levels if used.

•  The cable glands shall be mounted according to the manufacturer’s 

instructions, and additional clamping of the cable may be needed.

• 

Other certified cable glands than supplied with the product may be 

mounted and used according to the manufacturer’s instructions.

For complete documentation, see 

Installation & Maintenance Procedures for Exigo Ex 

Access Panels & Turbine Ex Intercoms

, Document no. A100K12133.

DNV 21 ATEX 04699X
IECEX DNV 21.0097X

A100K12140

Ex intercoms and access panels -V2- CE  

EU Declaration of Conformity

The following equipment is declared to be in conformity according to the following 

directives and international standards when the equipment is installed and used in a 

manner consistent with the manufacturer’s recommendations and reference documents.

Manufacturer:

Zenitel Norway AS

Bromsveien 17, 3183 Horten, Norway

Type of equipment:

Ex intercom stations and access panels

Product models:

Type name

Product number

TFIX-1-V2

1008123110

TFIX-2-V2

1008123120

TFIX-3-V2

1008123130

EAPFX-1-V2

1023221611

EAPFX-6-V2

1023221616

Relevant EU directives:

Directive 2011/65/EU

The restriction of the use of certain hazardous 

substances in electrical and electronic equipment.

Directive 2014/35/EU

Electrical equipment designed for use within certain 

voltage limits.

Directive 2014/30/EU

Electromagnetic compatibility

Directive 2014/34/EU

Equipment and protective systems intended for use 

in potentially explosive atmospheres

Harmonised standards applied:

Electromagnetic Emissions:

(by Council Directive 2014/30/EU)

EN IEC 61000-6-3:2021

EN IEC 61000-6-4:2019

Electromagnetic Immunity:

(by Council Directive 2014/30/EU)

EN 50130-4:2011 + A1:2014

EN IEC 61000-6-2:2019

Environmental:

EN/IEC 60945:2002 + Cor1:2008

Explosive atmospheres:

(by Council Directive 2014/34//EU)

EN 60079-0:2018

EN 60079-7:2015 + A1:2018

EN 60079-11:2012

EN 60079-18:2015 + A1:2017

Marking:

II 2(2)G Ex eb ib mb [ib] IIC T4 Gb

Ta: -20°C to +55°C

Type Examination Certificate:

DNV 21 ATEX 04699X, NB 2460

The manufacturer is solely responsible for making this declaration. The technical file is 

maintained at the company address listed above.

Name, Surname

Audun Kolle

Position/Title

Product Manager

Place of issue

Horten

Date of issue

16.12.2021

The relevant certificates and declarations of conformity may be 

downloaded from: www.zenitel.com/customer-service/library

1

Internal Mic+

2

Internal Mic -

3

Signal GND

4

Audio Accessory S

5

Audio Accessory Speaker -

6

Audio Accessory Microphone Mic +

7

Audio Accessory Microphone Mic -

8

Audio Accessory Push To Talk (PTT)

9

Audio Accessory Hook

10 Audio Accessory GND PTT/Hook

11 Internal Louds

12 Internal Loudspeaker -
13 GPI 1 External Push Button

24-48V DC

Flowire Bus

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

17 18 19 20 21 22 23 24 25

INT

Accessory

INT Push Buttons

EXT

EXT

Relay

In order to ensure the required minimum degree of 

protection, the cable glands must be tightened securely.
Over-tightening can impair the degree of protection and 

damage the Ex unit.
When tightening the cap nut of a cable gland, a suitable tool 

shall be used to prevent the gland from twisting.

Ex related document.
All changes must be approved

by Ex responsible in Zenitel. 

14 GND External Push Button
15 GPI 2 External Push Button
16 GND External Push Button
17 External Louds
18 External Loudspeaker -
19 Signal GND
20 Relay COM
21 Relay NO
22 Flowire PLC1 +
23 Flowire PLC1 -
24 Flowire PLC2 +
25 Flowire PLC2 -