background image

blue

 - 

blue

PRO

-Ex 

(ATEX - IECEx)

better together

use and maintenance booklet 

safety instructions

Содержание Blue Series

Страница 1: ...blue bluePRO Ex ATEX IECEx better together use and maintenance booklet safety instructions...

Страница 2: ...ISO 80079 37 2016 The aforesaid equipment has been approved by the following certification procedures ATEX type examination certificate Volountary request of Directive 2014 34 EU No EPT 16 ATEX 0228 X...

Страница 3: ...presence of inflammable gas mist or steam 4 1 3 NAMEPLATE SAFETY DATA 4 1 4 SAFETY 5 1 4 1 Training of installation and maintenance staff 5 1 4 2 Personal protective equipment PPE to use 5 1 4 4 Resi...

Страница 4: ...ied areas are established by the IEC 60079 14 standard The choice of type of pump according to these technical and legislative provisions must take into account the following factors Type of plant abo...

Страница 5: ...re safe reliable use However since it is intended for use with liquids that constitute a health hazard the installation and maintenance staff must take great care and always wear regulation personal p...

Страница 6: ...AP bluePRO Series drainage and evacuation of sewage clean sandy muddy water with small solid parts in potentially explosive atmosphere Not suitable for fluids for alimentary use Duty type S1 Degree of...

Страница 7: ...ted frequency Hz 50 60 rpm 2900 50Hz 3400 60Hz Insulation class F GR bluePRO pumps require starting capacitor See Point 2 8 NOTE Refer to the technical data sheet and to the data on the nameplate for...

Страница 8: ...anticlockwise If the pump is rotating in the wrong direction invert two of the power supply wires in the contactor and try again Once the correct rotation direction has been obtained MARK the power s...

Страница 9: ...rmed in safe area according manufacturer s instructions 2 9 FLOATING SWITCH The electric pump can be supplied with a floating switch and its functioning is completely automatic The floating switch has...

Страница 10: ...ed contact the dealer where this equipment was purchased or the ZENIT sales office in your area Once every 2 to 5 years Overhaul The pump must be overhauled even if the pump appears normal during oper...

Страница 11: ...he relay in accordance with the rated current on the name plate 4 Tripped residual current device RCD Low motor winding insulation Contact an authorised service center Fault in cable Have the cable ch...

Страница 12: ...rubber 8 Cable fastener Plastic 9 Cable gland support Plastic 10 Capacitor Plastic metal rubber 11 Motor case Cast iron 12 Bleeder valve Plastic rubber 13 Stator Cupper iron 14 Support washer Rubber...

Страница 13: ...rubber 7 Cable fastener Plastic 8 Cable gland support Plastic 9 Capacitor Plastic metal rubber 10 Motor case Cast iron 11 Stator Cupper iron 12 Support washer Stainless steel 13 Bearing Stainless ste...

Страница 14: ...50 DR blue 50 2 G40V 255 115 295 110 G 1 150 DR blue 75 2 G40V 255 115 325 110 G 1 150 DR blue 100 2 G40V 255 115 325 110 G 1 150 A mm B mm C mm D mm E F mm DG bluePRO 50 2 G40V 265 115 335 140 G 1 19...

Страница 15: ...O 100 2 G40H 270 130 365 95 G 1 220 14 90 90 180 GR bluePRO 150 2 G40H 285 125 410 100 G 1 230 14 90 90 180 GR bluePRO 200 2 G40H 285 125 410 100 G 1 230 14 90 90 180 A mm B mm C mm D mm E F mm G mm H...

Страница 16: ...zenit com Cod 27270100700400000 Rev 4 29 05 20 better together...

Отзывы: