background image

5

defrosting pipes.

• To avoid turning over install the 

machine on even surface.

Description

1. Positive socket (+) for connecting 

cable with electrode holder.

2. Negative socket for (-) for connecting 

cable with functional terminal.

3. Potentiometer with a scale. Allows 

adjusting welding current.

4. Thermostatic indicator. Indicator is 

off when the machine operates normally. 

Lit indicator means that temperature 

inside the machine is exceeded and the 

thermic protection has been activated. 

The machine is on but not powered 

until normal temperature is reached. 

After cooling the machine will start 

automatically.

5. Power indicator.

6. «On/Off» switch is on the back panel 

of the welding machine.

technical specifications

Model

MMA-300/2 

profi

Rated power

7.5 кW

Rated voltage

220-240 V

Rated frequency

50-60 Hz

Current control range  

20-300 А

Performance index

85%

Operating cycle*

75%

Power rate

0.93

Electrodes

1.6 - 5.0 mm

Net weight

5.2 kg

*Operating cycle: shows the period, 

within which the machine can generate 

corresponding current. It is expressed in 

%, based on 10 minutes per cycle e.g.: 

60% = 6 minutes of operation, 4 minutes 

of waiting etc.).

installation place

Install the machine in such a way so that 

ventilation openings are not obstructed 

(forced circulation). Do not allow 

aggressive steam, dust, humidity etc., 

inside the machine.

Fuse nomi-

nal, A

Welding 

current, A

Receptacle 

capacity, A

Cable sec-

tion, mm

16

130

16

16

20

160

32

16

20

180

32

25

25

200

32

25

Before connecting ensure that voltage, 

indicated on the machine nameplate, 

complies with the voltage and frequency 

of the mains.

connectinG welDinG cables

Any connection to the welding circuit 

must be performed when the machine is 

disconnected from the supply line.

Welding cable with electrode holder is 

connected to the positive pole (+) (see 

«Welding»).

Cable with functional terminal is 

connected to the negative pole (-), its 

Содержание MMA-300/2 PROFI

Страница 1: ...Instruction manual Inverter welding machine MMA 300 2 profi SEMI PROFI SERIES...

Страница 2: ......

Страница 3: ...contain long hair 9 Use eye protection Also use face or dust mask if the cutting operation is dusty 10 Connect dust extraction equipment If devices are provided for the connection of dust extraction...

Страница 4: ...Specifications of the welding inverters High speed and welding current adjustment accuracy which provide high welding quality using a welding electrode Welding inverter increases mains frequency from...

Страница 5: ...formance index 85 Operating cycle 75 Power rate 0 93 Electrodes 1 6 5 0 mm Net weight 5 2 kg Operating cycle shows the period within which the machine can generate corresponding current It is expresse...

Страница 6: ...n Max 1 6 25 50 2 40 80 2 5 60 110 3 2 80 160 4 120 200 Pay attention that depending on the diameter of the electrode higher values of welding current are used for welding in lower position whereas ve...

Страница 7: ...our head and neck It is recommended to wear closed safety boots with steel toe caps Welding seam specifications Electrode movement is too slow Very short arc Very low welding current Electrode movemen...

Страница 8: ...active substances as well as liquid and objects penetration provide effective cooling and wastes withdrawal from the tool working zone before disconnecting the tool from the power source turn off the...

Страница 9: ...9...

Страница 10: ...Demix LLC Head office 14 Shevchenko str 3rd floor Dnepropetrovsk Ukraine 49044 tel fax 38 056 375 43 16 http www en zenit profi com...