- 22 -
6.4.3. T command
Function
Pulse is output to the control signal “TRG”.
Format
T
CR LF
Return value
OK
CR LF
:
Pulse output is completed.
NG
CR LF
:
Pulse output error.
6.4.4. C command
Function
Pulse is output to control signal “CLR”.
Format
C
CR LF
Return value
OK
CR LF
:
Pulse output is completed.
NG
CR LF
:
Pulse output error.
6.4.5. D command
Function
I/O setting of 4 ports is executed.
All ports are set to input when turn on the power of ZS-6822.
Format
Dxxxx
CR LF
:
Set in the order of port_1, port_2, port_3, port_4 after “D”.
“x” is “I” for IN for input, “O” for OUT for output.
Return value
OK
CR LF
:
Setting is completed.
NG
CR LF
:
I/O setting error, data character error.
6.4.6. P command
Function
The pulse width of the control signals "STB" "TRG" "CLR" can be selected from 10µs,
100µs, 1ms, 10ms, 100ms.
When powering on the ZS - 6822, it is set to 10µs.
Format
P
x
CR LF
:
“x” is number. The assignment of number is as follows.
0
・・・
10
μ
s,
1
・・・
100
μ
s, 2
・・・
1ms
3
・・・
10ms,
4
・・・
100ms
Return value
OK
CR LF
:
Setting is completed.
NG
CR LF
:
Setting error, data character error.