The data sent from the PC is transferred sequentially from the small number of the port 

for output. Port set for input is also sequentially taken from small number and sent to PC. 
The data of each port is captured 4-bits at a time. 
 

 

e.g)

 

When ports 1 and 2 are set for input, and ports 3 and 4 are set for output. 

Order to send 

to PC 

Port data 

 

Order to output 

to the ZS-6222 

Port data 

 

Port_1 D7 to D4 

 

Port_3 D7 to D4 

Port_1 D3 to D0 

 

Port_3 D3 to D0 

Port_2 D7 to D4 

 

Port_4 D7 to D4 

Port_2 D3 to D0 

 

Port_4 D3 to D0 

             

0000 0001

D7

D0

0

1

0010 0011

D7

D0

2

3

1010 1011

D7

D0

A

B

1100 1101

D7

D0

C

D

1

2

3

4

ZS-6222

Input

Output

0123

ABCD

USB

 

 
 
 

5.2. Control signal 

A control signal is displayed so that it can be synchronized with the connected device. 

Signal  Direction 

Description 

STB 

OUT 

ZS-6222 completes receiving all data from the PC and outputs a pulse signal 
after parallel output. 
External device can be used this signal for Latch-Clock. 

TRG 

OUT  A pulse signal is output to an external device by “T” command. 

CLR 

OUT 

A pulse signal is output to an external device by “C” command. 
It is possible to be used resetting external devices. 

LAH 

IH 

When the latch circuit is enabled setting by “L” command, latch input data 
with this signal. Input a signal with a pulse width of 500µs or more. 

                Hote) The pulse width of the output can be set by command.   

It is possible to be set 10µs, 100µs and 1ms. 

     

 

Содержание ZS-6222 Series

Страница 1: ...1 ZS 6222 Series USB PIO Adapter User s Manual Zip code 183 0027 2 13 37 Honmachi Fuchu Tokyo Japan TEL M81 0 42 368 2126 FAX M81 0 42 364 0067 URL http www zenisu co jp...

Страница 2: ...pearance 4 4 Install 5 4 1 Download device driver 5 4 2 Windows Vista 5 4 3 Windows XP 2000 12 5 Operation 17 5 1 Transfer data method 17 5 2 Control signal 18 5 3 I O 19 5 4 Command chart 20 5 4 1 R...

Страница 3: ...Output Bidirectional data 4 Byte 3 2 Bit 2 Feature It is possible to be easily controlled with a laptop computer There are 4 ports 8bits port for parallel signals and I O can be selected with each po...

Страница 4: ...in type Data connector 50 coreflat cable 50 core flat cable Power supply DC4 75V to 5 25V 100mA or less DC4 75V to 5 25V 100mA or less Environment Tempreture0 to 50 Humidity85 or less Tempreture0 to 5...

Страница 5: ...ary to install hardware and device driver by following procedure at first Turn on the power to the PC and start Windows Connect this product and PC with a USB cable Install the device driver Complete...

Страница 6: ...6 Click Try other method Click Search the computer for driver software...

Страница 7: ...7 Refer to the downloaded file and click HEXT button It is displayed Issuer of driver software can not be verified but there is no problem Click Install this driver software...

Страница 8: ...8 Click Close button The following screen will be displayed Click Search and install driver software...

Страница 9: ...9 Click Try other method Click Refer to the computer and search for driver software...

Страница 10: ...10 Refer to the downloaded file and click HEXT button It will be displayed but there is no problem Click Install this driver software...

Страница 11: ...11 Click Close button...

Страница 12: ...he PC and start Windows 2 Connect this product and PC with a USB cable 3 Install the device driver 4 Complete the installation Device driver installation method is explained below The following screen...

Страница 13: ...location refer to the downloaded driver and click HEXT button The following screen will be displayed Only for XP It is displayed It has not passed Windows logo test to verify compatibility with Window...

Страница 14: ...be asked to reboot according to the configuration of the PC In that case restart according to the instructions on the screen The following screen will be displayed Select Install from the list or spe...

Страница 15: ...15 Select Search for the driver in the following location refer to the downloaded driver and click HEXT button There is no problem click Continue button...

Страница 16: ...16 Click Finish button After that it may be asked to reboot according to the configuration of the PC In that case restart according to the instructions on the screen...

Страница 17: ...umber and the value differs depending on the personal computer When creating a program please open it according to the displayed COM number Data code The data transfer method is used ASCII code and on...

Страница 18: ...0 1101 D7 D0 C D 1 2 3 4 ZS 6222 Input Output 0123 ABCD 5 2 Control signal A control signal is displayed so that it can be synchronized with the connected device Signal Direction Description STB OUT Z...

Страница 19: ...port the data sent last time will be remained in the empty space Received data 1 3 2 4 Output port_3 High Low High Low Output port_4 STB output 1 2 3 4 The data that is input from parallel port send t...

Страница 20: ...n Data is read from all ports set as input e g If input port is set four ports 8 bytes of data will be sent from ZS 6222 when R command is used Format R CR LF Return value xxxx CR LF Amount of data as...

Страница 21: ...t_1 port_2 port_3 and port_4 after D x is writes I for input O for output Return value OK CR LF Setting is completed HG CR LF Setting error wrong character setting 5 4 6 P command Function The pulse w...

Страница 22: ...19 20 D1 D2 21 22 D2 PORT D3 23 24 D3 PORT D4 25 26 D4 D5 27 28 D5 D6 29 30 D6 D7 31 32 D7 IN LAH 33 34 NC OUT STB 35 36 NC OUT TRG 37 38 NC OUT CLR 39 40 NC NC 41 42 GND NC 43 44 GND NC 45 46 GND NC...

Страница 23: ...ith instruction manual 2 It will be charged for extra in the following case even during warranty period Incorrect usage or failure or damage caused by carelessness Failure or damage caused by improper...

Отзывы: