Type BM24L10 EHEDG Load Cell
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.
Zemic Europe B.V.
T: +31 76 50 39480
Nr. 2023.11 BM24L10 Installation and Operating Manual Rev1
Page 6/7
4.2 Pre-Cautions
In the process of connecting cables, the following matters should be paid attention to:
1)
Pay attention to protection during connection, and do not damage the cable jacket.
2)
In general, it is not recommended to extend the cable. If this is a must, choose shielded, low
capacitance cables and make sure they are well connected with low contact resistance.
3)
Do not set the sensor cable in parallel with the power circuit and control circuit on the
installation site. If this is necessary, the sensor cables need to be shielded and protected.
5 Technical Specifications
Table 5-1 Technical Specifications
No.
Parameter
Unit
Value
1
Rated Capacity
t
5, 10, 20
2
Rated Sensitivity
mV/V
2.0 ± 0.01
3
Accuracy Grade
C1
4
Non-Linearity
%FS
± 0.05
5
Creep
%FS/30min
± 0.05
6
ZTC
%FS / 10°C
± 0.014
7
STC
%FS / 10°C
± 0.05
8
Zero Balance
%FS
± 1
9
Input Resistance
Ω
700 + 7
10
Output Resistance
Ω
700 + 5
11
Insulation Impedance
M Ω
5000 (@50V DC)
12
Compensated Temperature
°C
- 10 to +40
13
Operating Temperature
°C
- 35 to +70
14
Storage Temperature
°C
- 35 to +70
15
Excitation Voltage
V(DC)
5 ~ 12
16
Safety Overload
%FS
150
17
Ultimate Overload
%FS
200
18
Ingress Protection
IP68
19
Element Material
Stainless Steel 17-4PH
(AISI 630)
20
Sealing Ring & Sheath Material
Silicone Rubber RH200-50