Type BM24L10 EHEDG Load Cell

  

 

Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.

 

Zemic Europe B.V.

 

 

 

T: +31 76 50 39480

 

Nr. 2023.11 BM24L10 Installation and Operating Manual Rev1

 

[email protected] 

Page 6/7

 

 

www.zemiceurope.com

 

 

4.2 Pre-Cautions

 

In the process of connecting cables, the following matters should be paid attention to:

 

1)

 

Pay attention to protection during connection, and do not damage the cable jacket.

 

 

2) 

 

In general, it is not recommended to extend the cable. If this is a must, choose shielded, low

 

 

capacitance cables and make sure they are well connected with low contact resistance.

 

 

3) 

 

Do not set the sensor cable in parallel with the power circuit and control circuit on the

 

installation site. If this is necessary, the sensor cables need to be shielded and protected.

 

 
 

5 Technical Specifications

 

 

Table 5-1 Technical Specifications 

No. 

Parameter 

Unit 

Value 

Rated Capacity 

5, 10, 20 

Rated Sensitivity 

mV/V 

2.0 ± 0.01 

Accuracy Grade 

 

C1 

Non-Linearity 

%FS 

± 0.05 

Creep 

%FS/30min 

± 0.05 

ZTC 

%FS / 10°C 

± 0.014 

STC 

%FS / 10°C 

± 0.05 

Zero Balance 

%FS 

± 1 

Input Resistance 

Ω

 

700 + 7 

10 

Output Resistance 

Ω

 

700 + 5 

11 

Insulation Impedance 

M Ω

 

5000 (@50V DC) 

12 

Compensated Temperature 

°C 

- 10 to +40 

13 

Operating Temperature 

°C 

- 35 to +70 

14 

Storage Temperature 

°C 

- 35 to +70 

15 

Excitation Voltage 

V(DC) 

5 ~ 12 

16 

Safety Overload 

%FS 

150 

17 

Ultimate Overload 

%FS 

200 

18 

Ingress Protection 

 

IP68 

19 

Element Material 

 

Stainless Steel 17-4PH 

(AISI 630) 

20 

Sealing Ring & Sheath Material 

 

Silicone Rubber RH200-50 

 

Содержание BM24L10 Series

Страница 1: ...ct to change without notice and do not constitute any liability whatsoever Zemic Europe B V T 31 76 50 39480 Nr 2023 11 BM24L10 Installation and Operating Manual Rev1 info zemic nl www zemiceurope com...

Страница 2: ...nts 1 Safety Instructions 1 1 1 Specific Condition of Use 1 1 2 Safety Loading 1 1 3 Used as Equipment Unit 1 1 4 Additional Safety Precautions 1 1 5 General Risk of Non Compliance with Safety Instruc...

Страница 3: ...equirement It must be noted that when multiple load cells are mounted on single scale the load on every single load cell is not always evenly distributed and care must be taken not to overload them 1...

Страница 4: ...cations and cleaning instructions carefully particularly the technical specifications and cleaning method otherwise it may lead to damage of the sensor s and may result in property damage and or injur...

Страница 5: ...mm 5t 10t 8 8 20t 12 9 50 Nm 92 Nm Bottom 15mm 2 2 Pre Cautions During the sensor installation process the following matters should be noted 1 Operate the sensor carefully do not to bump or scratch th...

Страница 6: ...commended cleaning methods are as follows 1 Dry cleaning using tools including rag and or a soft brush 2 Wet cleaning using wet cloth chemicals low pressure clean water 3 2 Pre Cautions The operator s...

Страница 7: ...interfaces need to be sealed with sealing washers and there must be no threads exposed in the installed configuration of the machine feet The rubber sealing ring that is used to seal the space betwee...

Страница 8: ...sensor cable in parallel with the power circuit and control circuit on the installation site If this is necessary the sensor cables need to be shielded and protected 5 Technical Specifications Table...

Страница 9: ...without notice and do not constitute any liability whatsoever Zemic Europe B V T 31 76 50 39480 Nr 2023 11 BM24L10 Installation and Operating Manual Rev1 info zemic nl Page 7 7 www zemiceurope com 6 O...

Отзывы: