background image

Installation Manual BM-11-401 Mount

 

 

Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.

 

Zemic Europe B.V.

 

 

 

T: +31 76 50 39480

 

Nr. 2021.10 Installation Manual BM-11-401 Rev2

 

[email protected] 

Page 1/5

 

 

www.zemiceurope.com

 

 

 

 

 

General

 

Please read this 

BM-11-401 Mount

 installation manual carefully in order to profit fully from its benefits. 

Take care that the mounts and load cells are applied within their specifications. Certainly during 
installation special attention should be paid to exceptional forces exceeding these specifications. 
 

Dimensions

 

Description 

Dimension 5 

 200kg 

Dimensions 250 

 500kg 

Top Plate 

75mm x 90mm 

100mm x 120mm 

Bottom Plate 

130mm x 90mm 

160mm x 120mm 

Total Height 

77mm 

90mm 

 

Assembly 

Before installing the mount into the application, the stay rod assembly should be removed. The mount 
should be assembled and set to the installation height at which the load cell is not loaded: 
 

Capacity 

Working Height 

Installation Height 

Mounting Torque Load Cell 

5-50 kg 

77 mm 
3.03 inch 

81 mm 
3,19 inch 

15 Nm 
20.5 Lb ft 

100-200 kg 

77 mm 
3.03 inch 

81 mm 
3,19 inch 

25 Nm 
34 Lb ft 

250-500 kg 

90 mm 
3.54 inch 

94 mm 
3,70 inch 

40 Nm 
54 Lb ft 

Table 1 

 
 
 