Installation Manual BM-11-401 Mount
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.
Zemic Europe B.V.
T: +31 76 50 39480
Nr. 2021.10 Installation Manual BM-11-401 Rev2
Page 1/5
General
Please read this
BM-11-401 Mount
installation manual carefully in order to profit fully from its benefits.
Take care that the mounts and load cells are applied within their specifications. Certainly during
installation special attention should be paid to exceptional forces exceeding these specifications.
Dimensions
Description
Dimension 5
–
200kg
Dimensions 250
–
500kg
Top Plate
75mm x 90mm
100mm x 120mm
Bottom Plate
130mm x 90mm
160mm x 120mm
Total Height
77mm
90mm
Assembly
Before installing the mount into the application, the stay rod assembly should be removed. The mount
should be assembled and set to the installation height at which the load cell is not loaded:
Capacity
Working Height
Installation Height
Mounting Torque Load Cell
5-50 kg
77 mm
3.03 inch
81 mm
3,19 inch
15 Nm
20.5 Lb ft
100-200 kg
77 mm
3.03 inch
81 mm
3,19 inch
25 Nm
34 Lb ft
250-500 kg
90 mm
3.54 inch
94 mm
3,70 inch
40 Nm
54 Lb ft
Table 1