69
ZVC315-001_v02
Do not vacuum without HEPA/EPA inlet filter
(14) installed in “CYCLONE” dust container.
Lack of HEPA/EPA inlet filter (14) shall prevent
insertion of “CYCLONE” dust container to the
vacuum cleaner.
“MICROFILTER” OUTLET FILTER AND OUTLET
FOAM FILTER
1
In order to replace “Microfilter” outlet filter
(12)
press the
hook located in the filter cover and pull out the filter cover
from vacuum cleaner.
2
Pull out the “Microfilter” outlet filter
(12)
.
If the “Microfilter” outlet filter
(12)
is dirty, you can replace it with
a new filter, you can clean it or rinse with running water. Do not
forget to dry above mentioned filter before re-installation.
For safety reasons it is unacceptable to install
the moist or defective “Microfilter” outlet
filter (12).
3
Carefully insert a new / rinsed filter to previously
occupied space.
4
Pull out the foam outlet filter from filter cover
(1)
.
If the outlet foam filter
(13)
is dirty, you can replace it with
a new filter, you can clean it or rinse with running water. Do
not forget to dry above mentioned filter before re-installation.
For safety reasons it is unacceptable to install
the moist or damaged outlet foam filter (13).
5
Carefully insert a new / rinsed filter to previously
occupied space.
6
Put the filter cover so that two tips located at the right
side of the cover should hit the holes in the body of the
vacuum cleaner, press the filter cover so the hook snapped
in the body. Characteristic “click” sound informs, that the filter
cover has been properly installed.
Do not use the vacuum cleaner with no inlet
and outlet filters mounted in the device.
Damaged inlet and outlet filters must be always
replaced with new, factory original filters.
THE CONE OF “CYCLONE” DUST CONTAINER
It is necessary to clean periodically the “CYCLONE” dust
container cone.
1
Disassembly “CYCLONE” dust container according to
point
(C)
.
2
Press the button located on “CYCLONE” dust container
and open the bottom of the container. If “CYCLONE dust
container is full, empty it according to the point
(C)
.
3
Turn the cone left, so the two tips located on the flange of
the cone were put out from the slots of the container. Put out
the cone.
4
If the “CYCLONE” dust container cone
(17)
is dirty, you
can rinse it with running water. Do not forget to dry above
mentioned cone before re-installation.
E
F
Disassembly of filters
In case of dirty filters: inlet filter, foam filter (15),
HEPA/EPA inlet filter (14), outlet foam filter (13),
“Microfilter” (12) you can replace them with new
filters, clean them or rinse with running water.
Do not wash the filter in the washing machine
or dishwasher.
Filters can be dried in natural way only.
Do not dry the filters using hairdryers,
on heaters and radiators.
Before replacement of filters make sure that
vacuum cleaner is switched off and connection
cable plug is pulled out from the wall outlet.
INLET FILTER HEPA/EPA AND FOAM INLET FILTER
Vacuum cleaners are equipped with inlet filter HEPA type
H13 or EPA.
It is necessary to clean periodically the inlet filter HEPA/EPA
(14)
in order to remove minor fractions of the dust, and foam
inlet filter
(15)
must be also cleaned.
Disassembly the “CYCLONE” dust container and empty it in
accordance with paragraph
(C)
.
1
Remove the HEPA/EPA foam inlet filter
(14)
from
“CYCLONE” dust container.
2
Remove foam inlet filter
(15)
. If the foam inlet filter
(15)
is dirty, you can replace it with a new filter, you can clean
it or rinse with running water. Do not forget to dry above
mentioned filter before re-installation.
The main function of the foam inlet filter
(15)
is to protect
HEPA/EPA inlet filter
(14)
against excessive dirt.
For safety reasons it is unacceptable to install
the moist or damaged foam inlet filter (15).
●
Clean the pleats of HEPA/EPA inlet filter
(14)
, in case
of filter damage it should be absolutely replaced with
a new filter. If HEPA/EPA inlet filter
(14)
is dirty, you can
replaced it with a new filter, you can clean it or rinse with
running water. Do not forget to dry above mentioned filter
before re-installation.
For safety reasons it is unacceptable to install
the moist or damaged inlet filter HEPA/EPA (14).
●
Insert a new/rinsed inlet foam filter
(15)
into previously
occupied space.
3
Insert a new/rinsed HEPA/EPA inlet filter
(14)
to the dust
container into previously occupied space.
4
Insert “CYCLONE” dust container with mounted HEPA/
EPA inlet filter
(14)
to vacuum cleaner chamber. The
characteristic “click” indicates that container has been
correctly mounted.
It is recommended to replace HEPA/EPA inlet
filter (14) with a new one every 6 months of use.
D
Содержание ZVC315HP
Страница 27: ...33 ZVC315 001_v02 Zelmer Zelmer 8 230 16 A RU...
Страница 32: ...38 ZVC315 001_v02 K PE 4 5 6 7 8...
Страница 33: ...39 ZVC315 001_v02 Zelmer Zelmer 8 230 V 16 A BG...
Страница 38: ...44 ZVC315 001_v02 8...
Страница 39: ...45 ZVC315 001_v02 Zelmer Zelmer 8 230 16 A UA...
Страница 44: ...50 ZVC315 001_v02 8 a PE 26663 19848 5 40 1 15150...