CABLING ADVICE

WHAT IS THE BEST TYPE OF CABLE TO USE?

You can use Cat5e, Cat6 or greater with Zektor products.
The minimum cable standard for this system is Cat5e. Slightly greater distances may 

be achieved by using Cat6, or slightly better still with Cat7, which has stricter shielding 

requirements and reduces potential cross talk between data pairs. 
Whichever network cable type you choose, ensure that the main wiring architecture is 

solid core, not stranded patch cabling. Patch cabling can be used for the last few metres 

of a run (e.g. from a wall plate) but must be avoided over longer runs as signal transfer over 

stranded cores is heavily reduced. 
The use of pre-made leads is not recommended unless you can be absolutely sure of 

their construction credentials (i.e. solid core 568B). Please note that CCA (Copper Clad 

Aluminium) cable is NOT supported.

SHIELDED CABLES 

Unlike other systems, shielded FTP cable is not a stipulation. If, however, you prefer this type 

of cable please ensure compatible shielded accessories are used. Failure to terminate 

cable screen at all points can induce interference rather than eliminating it. 

CABLING BEST PRACTICE 

Our best practice policy is to terminate to a wall plate at either end and then use solid 

core patch cables (usually it is better to make your own than use pre-made) between the 

patch panel and the matrix and the wall plate and HDBaseT™ receiver.

HDBaseT™ WITH PATCH PANELS AND WALL PLATES 

If the patch panels are terminated correctly, there is minimal loss of distance. The use of 

wall plates and patch panels, however, has the potential to cause increased resistance 

on the cable if not done correctly, introducing pinch points for signal transmission, and 

could reduce advertised transmission lengths. Instead of using RJ45 wall plates, you can 

use brush plates to maintain the neat finish. 

CONNECTION TERMINATION 

Terminate the cabling using RJ45 connectors to the 568B wiring 

standard. (See fig1)

IMPORTANT: Please note that local building regulations may apply 

to the installation of cabling in properties. It is important to check 

building regulations to guarantee that you are in accordance 

with the laws of your territory.

fig1

MANUAL CONTENTS

P3 

Cabling Advice

P6 

Initial Setup

P7 

Audio Setup

P8 

Connect to the Web Interface

P10 

Setting up the Matrix Without an Internet Connection

 

Third Party Control Drivers

P11 

Setting up CEC

 

Front Panel LED Values

P12 

Supported Formats

P13 Troubleshooting
P14 

Concept Wiring Guide

P15 

Warranty Information

IMPORTANT CONCEPTS AND DEFINITIONS

When reading this manual we refer to devices that send video into the matrix system 

as source devices or sources, examples of source devices include Blu-Ray players, 

Set Top Boxes, Game Consoles and Media Centres.
Devices that receive video from the matrix are called sink devices or sinks. Examples 

of these are Amplifiers (AVRs) TVs and projectors.

2

IN THE BOX

Zektor Palladia gX Matrix Chassis

8x SoloCAT Ultra MAX PoH HDBaseT™ Receivers

8 Button Contextual Remote Control

8x IR Transmitter

8x IR Receiver

Rack Mounting Kit

48V Desktop Power Supply

Mains Cable

3

Содержание Palladia gX

Страница 1: ...VIDEO AUDIO MATRIX INSTALLATION GUIDE...

Страница 2: ...tch panels are terminated correctly there is minimal loss of distance The use of wall plates and patch panels however has the potential to cause increased resistance on the cable if not done correctly...

Страница 3: ...the internet at all times I Digital Optical and Coax Ports Connect to digital amp J System Health LED When the system is running correctly the LED will light green K Network LED When the system is co...

Страница 4: ...d rack ears Simply screw in the supplied M4 screws to connect the rack ears to the matrix 5 NETWORK CONNECTION This system is designed to be on and connected to an active internet connection at all ti...

Страница 5: ...y locally connected device via Wi Fi or a fixed wire connection You can access the web interface from a mobile tablet laptop or desktop PC Many of the controls in the user interface UI are drag and dr...

Страница 6: ...oring pulse eight com You must be logged in to access it If you have questions please speak with your distributor SETTING UP CEC Consumer Electronics Control CEC is a built in technology within HDMI w...

Страница 7: ...sible If you reduce the resolution of the source do you get a picture If so this suggests a conflicting resolution between source and display or a bandwidth capacity issue with your cable Check all in...

Страница 8: ...ned below Zektor will bear all costs of return shipping to owner except with respect to any Ineligible Product for which owner will bear all shipping costs 4 WHAT THIS LIMITED WARRANTY DOES NOT COVER...

Страница 9: ...US 1 858 748 8250 UK 44 1202 413610 sales zektor com 12635 Danielson Court Suites 201 202 203 Poway CA 92064 www zektor com...

Отзывы: