13
Read or record ZEISS eXtended Data on the MasterLockit
Plus
In order to record ZEISS eXtended Data the MasterLockit
Plus
must be setup correctly:
Camera, MasterLockit
Plus
and lens are connected according to your camera setup
Camera is up and running
MasterLockit
Plus
is up and running
Connect the MasterLockit
Plus
to a computer
While no connection to the computer is needed during the shot, it makes sense to use the web interface of the
MasterLockit
Plus
during setup to ensure that all parameters are correct.
via WiFi
The WiFi dongle must be connected to one of the MasterLockit
Plus
´s USB ports.
Open your network settings and search for WiFi Access Points.
Connect to the access point which name (SSID) begins with “mlp-”.
Type in the password. The password is identical to the name of the access point (mlp-…).
via Ethernet
Connect the Ethernet cable to your MasterLockit
Plus
.
Connect the Ethernet cable to your Computer or Laptop.
Access the MasterLockit
Plus
web interface
Open a web browser (we recommend Google Chrome).
Type in 10.0.0.1 OR masterlockit.local in the address bar.
In case the web interface does not appear, verify that the MasterLockit
Plus
is properly connected to your computer
via WiFi or Ethernet.
Synchronize MasterLockit
Plus
and camera
While the MasterLockit
Plus
records the ZEISS eXtended Data continuously, it is important to ensure that the
timecode and the Frame Rate are setup correctly and synchronized with the camera.
For ARRI and RED cameras: To set the timecode in your camera, connect your camera with the timecode cable with
the MasterLockit
Plus
. Go to the timecode settings in your camera menu and chose the following settings:
ARRI cameras:
TC
Options
Source: Ext LTC
Mode: Free Run
Generator: Regen
RED cameras:
Menu
Settings
Project
Frame Rate
Project Time Base: select your Frame Rate, for example 23,98 FPS
Menu
Settings
Project
Timecode
TC Display Mode: TOD
Source: External
Содержание Compact Prime CP.3 XD
Страница 3: ... LEMO is a registered trademark of INTERLEMO HOLDING S A ...
Страница 28: ...27 Appendix Lens data cable MLC CP Power cables AK XLR4M AK HS4 PC2M ...
Страница 29: ... Camera metadata cables MLC L1B10P ACN RCP Timecode cables TC I O TC I O RA Right Angle ...
Страница 30: ...29 LTC Out EPIC LTC OUT TC OUT ...
Страница 31: ...Carl Zeiss AG Camera Lenses 73446 Oberkochen Germany www zeiss com cine ...