![background image](http://html1.mh-extra.com/html/zeiss/compact-prime-cp-2/compact-prime-cp-2_change-instructions_3332412013.webp)
13
Compact Prime CP.2 21/T2.9
Meter distance scale
Feet distance scale
Distance to test chart [mm]: 1000
Distance to test chart [ft]: 4
Object distance
at best focus [mm]:
Change of total
shim thickness [mm]:
Object distance
at best focus [ft]:
Change of total
shim thickness [mm]:
940
-0.04
3ft 8'
-0.04
955
-0.03
3ft 9'
-0.03
970
-0.02
3ft 10'
-0.02
985
-0.01
3ft 11'
-0.01
1000
0.00
4ft 0'
0.00
1015
+0.01
4ft 1'
+0.01
1030
+0.02
4ft 2'
+0.02
1045
+0.03
4ft 3'
+0.03
1060
+0.04
4ft 4'
+0.04
Compact Prime CP.2 25/T2.9
Meter distance scale
Feet distance scale
Distance to test chart [mm]: 1000
Distance to test chart [ft]: 4
Object distance
at best focus [mm]:
Change of total
shim thickness [mm]:
Object distance
at best focus [ft]:
Change of total
shim thickness [mm]:
960
-0.03
3ft 8'
-0.05
970
-0.02
3ft 9'
-0.04
980
-0.02
3ft 10'
-0.03
990
-0.01
3ft 11'
-0.01
1000
0.00
4ft 0'
0.00
1010
+0.01
4ft 1'
+0.01
1020
+0.02
4ft 2'
+0.03
1030
+0.02
4ft 3'
+0.04
1040
+0.03
4ft 4'
+0.05