3.3

 

Standard delivery 

   

 

The following parts are included in the delivery:  

 

flow cup / immersion flow cup 

 

certificate of manufacturer 

 

storage box 

 

 

3.4

 

Options 

  

 

For ZFC 3010, ZFC 3011 and ZFC 3013: 

 

ZTJ 3020 Temperature Control Jacket 

 

ACC050 insertion thermometer up to 600°C 
(1‘112°F) (for fluids) 

 

ACC072 three-foot stand completely made of 
stainless steel, levelling, adjustable feet, with 
spirit level, height of 260 mm (10.24“) 

 

ACC152 glass plate 

 

 

For ZFC 3010-3015: 

 

ACC593 calibration and certification  
(incl. certificate) 

 

 

 

Zehntner GmbH Testing Instruments refuses all warranty and liability 
claims for damages caused by usage of the ZFC 3010 – 3015 in combination 
with non-original accessories, or accessories from 3

rd

 party suppliers. 

 

 

 

Содержание ZFC 3010

Страница 1: ...ZFC 3010 3015 Flow Cups Immersion Flow Cups Instruction manual ...

Страница 2: ......

Страница 3: ...notes and hints 6 3 Delivery of device 7 3 1 Damages during carriage 7 3 2 Shipment 7 3 3 Standard delivery 8 3 4 Options 8 4 Handling flow cups 9 5 Handling immersion flow cups 10 6 ACC072 three foot stand 10 6 1 Standard delivery 10 6 2 Mounting the ACC072 three foot stand 11 7 Technical specification 13 Glossary 14 ...

Страница 4: ...ntner to update Some of the images shown in this instruction manual may be of a preproduction model and or are computer generated therefore the design features of the delivered product may differ in various aspects The instruction manual has been drafted with the utmost care Nevertheless errors cannot be entirely excluded The manufacturer will not be liable for errors in this instruction manual or...

Страница 5: ... determination of the flow time of paints varnishes and similar liquids Application application areas For paint and varnish manufacturers and fabricators as well as test laboratories For use in laboratories and during production In particular this instrument has the following features Easy to handle Easy to clean ...

Страница 6: ... Safety notes and hints The ZFC 3010 3015 is exclusively intended for rapid determination of the flow time of paints varnishes and similar liquids Any other use is considered as not being in accordance with the intentions of the manufacturer The manufacturer is not liable for damage resulting from inappropriate application The user bears the full responsibility Unauthorized modifications and chang...

Страница 7: ... the courier liable immediately in the following way When opening the parcel we had to notice that etc This superficial checking of the goods has to be done within the time limit set by the carrier which is normally 7 days However the period could vary depending on the courier Hence it is recommended to check the exact time limit when receiving the goods If there are any damages also inform your a...

Страница 8: ... up to 600 C 1 112 F for fluids ACC072 three foot stand completely made of stainless steel levelling adjustable feet with spirit level height of 260 mm 10 24 ACC152 glass plate For ZFC 3010 3015 ACC593 calibration and certification incl certificate Zehntner GmbH Testing Instruments refuses all warranty and liability claims for damages caused by usage of the ZFC 3010 3015 in combination with non or...

Страница 9: ...d will be caught by the spillover furrow Slide a glass plate over the rim of the cup so that no air bubbles will be formed between the glass plate and the surface of the sample Place a suitable receiving vessel under the flow cup so that the distance between the orifice and the vessel is at least 10 cm Remove the finger from the orifice draw the glass plate away horizontally and simultaneously sta...

Страница 10: ...ly start the timing device Stop the timing device as soon as the stream of the sample breaks for the first time close to the orifice The average out of 3 measurements will give the flow time 6 ACC072 three foot stand 6 1 Standard delivery The ACC072 three foot stand consists of the following parts 1 holding ring ACC1527 2 supporting legs with adjustable feet 1 supporting leg with fixed foot 1 comb...

Страница 11: ...the ACC072 three foot stand Before the first use the three foot stand has to be mounted Screw the 3 supporting legs into the holding ring Tighten the 3 supporting legs with the combination wrench Adjustable foot fixed foot ...

Страница 12: ...Page 12 Level the stand with the 2 supporting legs with adjustable feet The three foot stand is ready to use now Adjustable foot Adjustable foot ...

Страница 13: ...withdrawn 1996 ZFC 3012 1 2 3 4 5 6 7 or 8 based on DIN 53211 withdrawn 1996 ZFC 2013 3 4 5 or 6 ASTM D5125 EN ISO 2431 BS 3900 A6 withdrawn 1991 ZFC 3014 3 4 5 or 6 ASTM D5125 EN ISO 2431 BS 3900 A6 withdrawn 1991 ZFC 3015 1 2 3 4 or 5 ASTM D1200 Please specify jet No when ordering Material cup anodised aluminium Material jet stainless steel Warranty 2 years ...

Страница 14: ... delivery ACC072 three foot stand 10 Flow cups 8 F Features 5 H Handling Flow cups 9 Immersion flow cups 10 I Instrument Damages 7 Delivery 7 Description 5 Extent of delivery 8 M Mounting the ACC072 three foot stand 11 O Options 8 S Safety information 6 Shipment 7 Standard delivery ACC072 three foot stand 10 Flow cups 8 T Technical specification 13 Transportation Damages 7 ...

Страница 15: ......

Страница 16: ...Zehntner GmbH Testing Instruments Gewerbestrasse 4 CH 4450 Sissach Switzerland Tel 41 0 61 953 05 50 Fax 41 0 61 953 05 51 zehntner zehntner com www zehntner com Version 2 9 dated 29 09 2017 ...

Отзывы: