Issue 1.0

Model

800

1200
1500

Height*

± 2mm

500
500
500

Width

± 2mm

mirror
mirror
mirror

Finish

8

12
15

Weight

kg

All dimensions shown are in millimetres

 

All stainless steel construction:  

dia 32mm x 1mm tubes

 

 

 

 

dia 38mm x 1.5mm headers

 

Connections:  

 

 

1.2m long flying lead (3 core)

 

Immersion heater rating: 

 

IPX4 or better

Output

Watts

150
200
250

* does not include immersion heater

PERE-080-050/F
PERE-120-050/F
PERE-150-050/F

78-103

height

100

100

width

19

19

PERE-080

PERE-150

PERE-120

72

fixing centres

Содержание Pera Electric PERE-080-050/F

Страница 1: ...500 500 500 Width 2mm mirror mirror mirror Finish 8 12 15 Weight kg All dimensions shown are in millimetres All stainless steel construction dia 32mm x 1mm tubes dia 38mm x 1 5mm headers Connections 1 2m long flying lead 3 core Immersion heater rating IPX4 or better Output Watts 150 200 250 does not include immersion heater PERE 080 050 F PERE 120 050 F PERE 150 050 F 78 103 height 100 100 width 1...

Страница 2: ...1 as long as the electrical controls are out of reach of anyone using the bath or shower The electricity supply must be protected by a residual current device with a maximum of 30mA especially when installed in a room containing a bathtub or shower WARNING This heater is not equipped with a device to control the room temperature Do not use this heater in small rooms when they are occupied by perso...

Страница 3: ...is safe ensure that an area of at least 50cm in front of the appliance is clear of objects which might hinder air circulation furniture chairs etc position a shelf at least 10cm above the top of your radiator use mounting screws suitable for your wall NOTE Electric towel radiators are designed to be covered safely However to ensure that your appliance works efficiently you are advised not to cover...

Страница 4: ...al Live Earth ROUTINE MAINTENANCE OPERATIONS Before carrying out any maintenance operation on your appliance ensure that it is switched off High quality materials and surface treatment protect your radiator To maximise the service life of your radiator we recommend you take the following precations to make the most of the performance of radiators containing a heat transfer fluid it is advisable to...

Страница 5: ...N 60 335 2 30 and subsequent amendments Dated proof of purchase must be presented to activate the guarantee The guarantee does not cover radiator transport removal and installation costs The guarantee shall not apply if the appliance is installed used or maintained in a way that does not comply with standards in force in the relevant country good professional practice or the manufacturer s instruc...

Страница 6: ... Accurately mark out bracket holes on wall using spirit level Drill four 10mm diameter holes to a minimum depth of 70mm insert wall plugs A Screw brackets B into wall plugs A with 6 3mm diameter x 60mm screws C Slide boss on radiator into bracket B and secure in position by tightening grub screw D with allen key E Electric radiators should be fitted only by a qualified electrician and must be eart...