 Carefully read this manual before use.

This manual provides all the information required for safe 
and  optimal  installation,  operation  and  maintenance  of 
the ComfoAir 200 Luxe. It is also intended as a reference  
for servicing, so that this can be carried out in a respon-
sible manner. The device is subject to continuous devel-
opment and improvement. As a result, the ComfoAir 200 
Luxe may slightly differ from the descriptions.

NOTE

This manual has been compiled with  

the most care. However, no rights can be 

derived from it. In addition, we at all times 

reserve the right to change the contents of 

this manual, without prior notice.

1    Introduction

The device's name is ComfoAir 200 Luxe. In the following 
it will be referred to as ComfoAir.
The ComfoAir is a balanced ventilation system with heat 
recovery in order to create healthy, balanced and energy-
efficient  ventilation  in  houses.  The  ComfoAir  has  a  UL 
marking  on  the  identification  plate.  The  identification 
plate can be found on side of the ComfoAir.

1.1   Warranty and liability

1.1.1  Warranty conditions

The  ComfoAir  is  covered  by  a  manufacturer’s  warranty 
for a period of 24 months after fitting up to a maximum 
of  30  months  after  the  date  of  manufacture.  Warranty 
claims may only be submitted for material faults and/or 
construction faults arising during the warranty period. In 
the case of a warranty claim, the ComfoAir must not be 
dismantled  without  written  permission  from  the  manu-
facturer.  Spare  parts  are  only  covered  by  guarantee,  if 
they were supplied by the manufacturer and have been 
installed by an approved installer.

The warranty becomes invalid if:

   The warranty period has elapsed;

  The device is used without filters;

  Parts  are  used  that  have  not  been  supplied  by  the 

manufacturer;

  Non-authorised changes or modifications have been 

made to the unit.

1.1.2  Liability

The  ComfoAir  has  been  designed  and  manufactured 
for  use  in  balanced  ventilation  systems  incorporating 
Zehnder heat recovery systems. Any other application is 
seen as inappropriate use and can result in damage to 
the ComfoAir or  personal injury, for which the manufac-
turer cannot be held liable.
The manufacturer is not liable for any damage originat-
ing from:

  Non-compliance with the safety, operating and main-

tenance instructions in this manual;

  The use of components not supplied or recommend-

ed by the manufacturer.

 

Responsibility  for  the  use  of  such  components  lies 
entirely with the installer;

  Normal wear and tear.

Содержание ComfoAir 200 HL

Страница 1: ...Cooling Fresh Air Clean Air Heating ComfoAir 200 Luxe Installer manual...

Страница 2: ...l has been compiled with the most care The publisher cannot be held liable for any damage caused as a result of missing or incorrect information in this manual In case of disputes the Dutch version of...

Страница 3: ...g on the wall 8 2 6 3 Connection of the air ducts 8 2 6 4 Connection of the condensation drain 9 2 7 Commissioning the ComfoAir 9 2 7 2 P menus for the installer 11 2 8 Programming air specifications...

Страница 4: ...od of 24 months after fitting up to a maximum of 30 months after the date of manufacture Warranty claims may only be submitted for material faults and or construction faults arising during the warrant...

Страница 5: ...not allowed Always take ESD inhibiting measures when deal ing with electronics such as wearing an antistatic wristband The electronics can be damaged by static charges The ComfoAir is only suitable fo...

Страница 6: ...th high efficient fan HR High Efficient heat exchanger F Connector panel H2 with connections for external switches and controllers Control panel H1 with connections for the fans the bypass temperature...

Страница 7: ...n w c 125 Pa 1 10 A Electricity Power supply 240 50 60 V Hz Cos phi at Maximum 0 8 Connecting Power 1 49 kW Maximum Power Pre heater 1 35 kW Leakage current 1mA Supply fan noise level at 0 m Position...

Страница 8: ...Power 1 49 kW Maximum Power Pre heater 1 35 kW Leakage current 1mA Supply fan noise level at 0 m Position Ventilation capacity Sound power Absent Setting 11 77 CFM 20 m3 h at 0 01 in w c 3 Pa 37 db A...

Страница 9: ...6 EN 2 3 Dimension sketch...

Страница 10: ...is supplied in the following types Type ComfoAir 200 L Luxe ERV ComfoAir 200 R Luxe ERV Meaning of the suffixes L Left version R Right version ERV Contains a enthalpy exchanger by default Luxe Contain...

Страница 11: ...ile installing the air ducts Install the air exhaust duct so it drains in the direction of the ComfoAir Insulate the outside air supply and the air exhaust duct between the roof wall passage to render...

Страница 12: ...st be commissioned This can be done via the P menus on the digital operat ing device These P menus can be used to enter vari ous settings ventilation programmes in particular for the ComfoAir An overv...

Страница 13: ...e input 0 Min 15 Min 0 Min P22 Optional Note Only applies to systems fitted with a corded switch and a second switch in the bathroom Overrun timer for the bathroom switch to switch to normal position...

Страница 14: ...city in of the exhaust fan to HIGH POSITION 18 100 nL HL 70 90 P34 Setting the capacity in of the supply fan to ABSENT POSITION 0 or 15 97 nL HL 15 15 P35 Setting the capacity in of the supply fan in...

Страница 15: ...type Li Left hand version Re Right hand version Li Re Li With delivery the ComfoAir is correctly pre programmed at the factory After an general reset the pre programming is lost and the setting must b...

Страница 16: ...oAir will run at maximum Rotation Per Minute RPM The bypass valve will open and close P77 Resetting filter dirty counter 0 1 activate 0 Note This resets the counter that triggers a dirty filter alert...

Страница 17: ...ode the bypass valve is al ways closed After 30 minutes the ComfoAir au tomatically terminates the programming mode 2 Close all windows and outside doors 3 Close all inside doors 4 Check the presence...

Страница 18: ...ecessary cleaning the heat ex changer Inspecting and if necessary cleaning the fans A concise explanation of these maintenance activities is given in the paragraphs below Check the condensation drain...

Страница 19: ...um of 1 5 Nm This is roughly equal to setting 2 of an average battery powered drill 2 9 2 Inspecting and cleaning the fans Check the fans once every 2 years 1 Remove the heat exchanger as instructed i...

Страница 20: ...ription A0 n a A1 NTC sensor T1 is defective outside air temperature A2 NTC sensor T2 is defective supply air temperature A3 NTC sensor T3 is defective return air temperature A4 NTC sensor T4 is defec...

Страница 21: ...function Yes No Was the temperature 27 C or 127 C Reset the unit P74 on 1 Disconnect the power from the ComfoAir Disconnect the power from the ComfoAir Disconnect the power from the ComfoAir Release t...

Страница 22: ...control circuit board Activate the self test P76 on 1 Did the bypass motor run Yes Disconnect the power from the ComfoAir Replace the control circuit board Remove the motor Disconnect the power from t...

Страница 23: ...everse order Reconnect the power to the ComfoAir No Reconnect the power to the ComfoAir Is there 12VDC present on the Luxeconnection panel Yes Disconnect the power from the ComfoAir Replace the Luxe c...

Страница 24: ...onnect the power from the ComfoAir Replace the control circuit board Is a control signal 1 5 10 VDC present on the fan Yes No Disconnect the power from the ComfoAir Replace the control circuit board R...

Страница 25: ...he ComfoAir Install all parts in reverse order Reconnect the power to the ComfoAir Disconnect the power from the ComfoAir Replace the connection panel Are the connections at the ComfoAir correct Disco...

Страница 26: ...panel 2x to reset the FLTR warning Disconnect the power from the ComfoAir Remove the filter caps from the ComfoAir Remove the dirty filters from the ComfoAir Slide the clean new filters back into the...

Страница 27: ...o air supply shower remains damp Filters blocked Replace the filters Valves blocked Clean the valves Exchanger clogged by dirt Clean the exchanger Exchanger frozen Defrost the exchanger Fan dirty Clea...

Страница 28: ...umber Part Article number 1 Fan Right hand Green 400200034 2 Fan Left hand Red 400200035 3 Control panel 400300051 4 Connector panel 400300031 5 Temperature sensor T1 T3 400300049 6 Temperature sensor...

Страница 29: ...26 EN 2 12 Wiring diagram ComfoAir 200 RIGHT HAND version...

Страница 30: ...EN 27 2 13 Wiring diagram ComfoAir 200 LEFT HAND version...

Страница 31: ...uct ComfoAir 200 UL L R Luxe ERV UL file number E345822 2 15 Temperature conversion table C F C F 5 41 0 23 73 4 6 42 8 24 75 2 7 44 6 25 77 0 8 46 4 26 78 8 9 48 2 27 80 6 10 50 0 28 82 4 11 51 8 29...

Страница 32: ...Zehnder America Inc 6 Merrill Industrial Drive Suite 7 Hampton NH 03842 603 601 8544 info zehnderamerica com www zehnderamerica com ZGNL Manual_40011015 V0117 EN Subject to change...

Отзывы: