background image

5

3.1.1           

How to navigate through the unit menu

                  1.  Lift cover on front of unit.
                  2.  Press the 'Control Button' to activate the panel.
                  3.  Rotate the button clockwise or anti-clockwise to required setting of either 'User Menu' or 'Service Menu' and 
                  

press the button.

                  3.  Scroll to the required option and press button.
                  4.  The current setting status will flash.
                  5.  Rotate button to desired outcome.
                  6.  Press button to confirm.
                  7.  Screen will time out after 30 seconds.

                  

                   Steps of the User Menu

Status Log

HumidiS    mart

TimerSmart

Summer Bypass

User Menu

User Settings

V

GRC1 Boost

EXIT

Optional Controller

Service Log

H/Exch Change

Runtime - Days

Software

EXIT

Filter Change

Filter Change

H/Exch Change

Fan Failure

Bypass Failure

Reset Filter

Reset H/EX

Setup Menu

Service Menu

Installer Only

Low Speed On

Switch Live On

Humidity Boost

Overrun Boost

OFF

ON

BMS Boost

Bypass Open Auto

Supply Motor Off

Port Config-LH

High Speed On

AUX Live On

Port Config-RH

Bypass Open Man

Aux Speed On

Frost Protect On

Sensitivity

OFF

ON

AUTO

MAN

OFF

MODE 1

MODE 2

Note: Status log menus
only visible when active

Содержание ComfoAir 185 WM

Страница 1: ...ComfoAir 185 WM Mechanical Ventilation with Heat Recovery User Homeowner Guide CA185WM GB...

Страница 2: ...Your Home 1 1 Your home has a Heat Recovery Ventilation System installed This consists of a continuously running Supply and Extract System with Heat Recovery that is linked by a network of ducts to ex...

Страница 3: ...ay and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision 2 1 4 Where an open flued oil or gas f...

Страница 4: ...arning message always indicated by flashing text and exclamation marks Please note that this message will time out and return to the previous screen S U M M E R B Y P A S S M A N Example 2 Function Se...

Страница 5: ...0 seconds Steps of the User Menu Status Log HumidiSmart TimerSmart Summer Bypass User Menu User Settings V GRC1 Boost EXIT Optional Controller Service Log H Exch Change Runtime Days Software EXIT Filt...

Страница 6: ...uto Manual Off Frost protection monitors the internal and external temperature and automatically identifies when the frost protection needs to be activated protecting your unit from freezing Smart Hum...

Страница 7: ...d to switch between low and high speeds as well as provide system status updates Press control button to activate panel Scroll to User Menu option and press button to enter Scroll to Summer Bypass opt...

Страница 8: ...ed this can affect overall system performance For this reason it is important to check the filters regularly and to replace them as often as each year See Section 4 1 9 Periodic inspection and or clea...

Страница 9: ...cates the number of logs for review Scroll to Filter Change option and press button The request to reset timer will flash Press to confirm Screen will time out after 30 seconds Note details on the Ser...

Страница 10: ...n to activate panel Scroll to Service Menu option and press button to enter Scroll to Software option to review Screen will time out after 30 seconds S O F T W A R E v 1 9 2 1 1 2 Step 1 Isolate the u...

Страница 11: ...h a vacuum cleaner and wash with warm water Gently clean the motor impellers on both sides of the unit by using a brush Ensure heat exchanger is dry before continuing to Step 5 Step 5 Re insert the cl...

Страница 12: ...back into place at the top v Turn the Mains Supply back on Reset Heat Exchanger Status See Section 4 1 6 Note details on the Service Maintenance Log on page 14 Important Note Do not attempt to clean...

Страница 13: ...ke care when removing the valve to leave the rubber ring in place Step 1 Mark the location and setting of the valve Do not change the settings of the valve as it would negatively influence the system...

Страница 14: ...Activity Initials 12 months after installation Activity Y1 Y2 Y3 Y4 Y5 Clean the valves Fill the condensation drain of the domestic waste water system Replace the filters note filter serial number wit...

Страница 15: ...water system Date Activity Initials 12 months after installation Activity Y6 Y7 Y8 Y9 Y10 Clean the valves Fill the condensation drain of the domestic waste water system Replace the filters note filte...

Страница 16: ...ication System 4 Continuous Mechanical Supply and Extract with Heat Recovery Manufacturer Zehnder Group UK Limited Model Number Serial Number where available Location of MVHR Unit 1 1 Installation Che...

Страница 17: ...een rooms Yes No i e 10mm over and above final floor finish Has all protection packaging been removed including from background ventilators Yes No such that system is fully functional For ducted syste...

Страница 18: ...nspections General Systems 1 3 and 4 only Schedule of air flow measurement equipment used Date of last UKAS calibration model and serial 1 2 3 Part 3 Airflow measurement test and commissioning details...

Страница 19: ...Low Rate l s Design Air Flow Low Rate l s Refer to Table 5 1b in ADF If applicable Measured Air Flow AUX Rate l s 3 6 Test Engineer s Details Name Company Address Line 1 Address Line 2 Telephone Numbe...

Страница 20: ...going to press E OE All goods are sold according to Zehnder s Standard Conditions of Sale which are available on request All dimensions referred to are in millimetres unless otherwise stated Zehnder...

Отзывы: