background image

12

13

Z23720

Z23720

lost. After the 230Vac power supply comes back, if chrono mode is selected, the sym-

bol     and the display writing flickers (the time): in that case following the procedure 

described at the beginning of the paragraph it is possible to set the time. Until the 

operation is not performed, the device temporarily counts the time from the moment 

when the power supply 230Vac has become available again (and this «temporary» 

time is used in case you selected the chrono mode).

3.4 Pilote wire mode

In the Pilote Wire mode, the setpoint temperature (set locally into the Comfort 

mode) is modified depending on the commands received from the Pilot Wire control 

unit, except the case with Pilot wire not connected or class I devices (appliances with 

eath connection). 

The device recognizes 6 commands: Comfort, Reduction (setpoint temperature 

-3.5°C), Stop, Frost protection (7°C), Eco1 (setpoint temperature -1°C) and Eco2 (set-

point temperature -2°C).

Pilote Wire 

icon

Symbol of FP command 

recognized (see table)

Setpoint temperature

Pilote-Wire signal

Display

Temperature

  COMFORT

   

   Setpoint temperature 

  REDUCTION

      

  (Setpoint temperature – 3,5°)

  ECO1

  (Setpoint temperature - 1°C)

  ECO2

      

  (Setpoint temperature – 2°C)

  FROST PROTECTION    

  7°C

  STOP

 

  Stop

The STOP command is enabled in all modes, except for the standby state. 

If the STOP command was implemented outside of the mode Pilote Wire, the 

icon       blinks.

With the STOP command present is still possible to put the device in stand-by 

state pushing the ON/Stand-by button     .

3.5 Electronic lock

This function is used to block the buttons so that they cannot be used. It may be 

useful to activate it to avoid inadvertent setting changes or tampering by unauthorized 

persons or children. To activate, hold down the 

+

 and 

 buttons simultaneously for at 

least 3 seconds. A padlock icon      appears when the buttons are blocked.

With the loocking function active is still possible to put the device in stand-by 

state or in ON state pushing the ON/Stand-by button      , but it is not possible to change 

setting or mode.

To deactivate the function, hold down the 

+

 and 

 buttons simultaneously for 

at least 3 seconds. The padlock icon will disappear and the buttons can be used 

normally.

Содержание Bisque 4FE-40-55/F

Страница 1: ...F 24 32 40 46 24 33 38 45 26 34 45 53 67 475 475 475 475 575 575 575 575 675 675 675 675 675 642 826 1010 1148 550 734 826 964 504 642 826 964 1194 136 136 136 136 136 136 136 136 136 136 136 136 136...

Страница 2: ...d outside the bathroom Note for maintenance purposes cable outlets must remain accessible and cables must not be buried directly into walls FITTING INSTRUCTIONS Wall plugs 10mm Screws 7mm diameter x 6...

Страница 3: ...ack of experience and knowledge if they have been given supervision or instruc tion concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the a...

Страница 4: ...d the room temperature when the appliance is switched on this principle also ensures consistent and sustained heating even when the element is no longer powered 2 Installing your appliance 2 1 Warning...

Страница 5: ...wherever possible You will find a complete set of assembly instructions in your appliance s box 2 3 Connecting the appliance The technical specifications of your radiator are shown on its nameplate Pl...

Страница 6: ...lue or grey 3 Operating the electronic control 3 1 Description of control unit The ON Stand by button switches the regulator ON or puts it on standby when the device is on standby the display shows a...

Страница 7: ...to the current setpoint temperature value the one shown in the Comfort mode FROST PROTECTION position Your radiator is set to ensure a minimum temperature of 7 C in your room to prevent any risk of f...

Страница 8: ...see table Setpoint temperature Pilote Wire signal Display Temperature COMFORT Setpoint temperature REDUCTION Setpoint temperature 3 5 ECO1 Setpoint temperature 1 C ECO2 Setpoint temperature 2 C FROST...

Страница 9: ...appliance s nameplate the sales reference for your appliance shown on your dated purchase invoice Guarantee See general conditions of sale for your country The heating body of your electric radiator...

Отзывы: