9
PROGRAMMING AND SETTING NEW PARAMETERS
While programming or reading,
control unit
does not need to be connected to power supply,
because it is supplied through PC-USB programmer.
Changing control unit parameters
Read parameters from connected
control unit
, by pressing
Read
button.
Progress bar indicate read and verify process.
Successful reading is indicated as:
Error while reading is indicated as:
If error occurs, then repeat reading.
Change parameters
Program parameters to connected
control unit
, by pressing
Program
button.
Progress bar indicate program and verify process.
Successful programming is indicated as:
Error while programming is indicated as:
If error occurs, then repeat programming.
Make new *.zee file without connecting control unit
Connect PC-USB programmer to PC.
Set parameters
Save parameters by clicking
Save As
from
File menu
.
TPS Close Position [0%]
TPS close position must be calibrated, For correct operation of TPS function!
TPS close position can be set manually by entering number, or calibrated by clicking on
Calibrate
button.
Using
Calibrate
function is more recommended.
Clicking on
Calibrate
button opens
Calibrate TPS Close Position
window.
to finish calibration: hold throttle at full close position and press
OK
button
to cancel calibration: press
Cancel
button