Every time you make any changes to ignition curve, it is automatically saved to #0 position.
Then you can save it to any other position number from #1 to #2.
Curve Example with six curve points:
5.1.
Change NUMBER OF IGNITION CURVE POINTS
Move to
Nr. of Points
with pressing + or - and then press enter .
Now you can select number of ignition points, with pressing + or - and then press enter .
5.2.
Change PARAMETERS OF IGNITION CURVE POINT
Move to point you want to change, with pressing + or - and then press enter .
Now you can change rev point with pressing + or - (in 100 rpm steps) and then press
enter .
Now you can change advance angle with pressing + or - (in 0.1deg steps) and then press
enter .
6. Set
ADVANCE
With this setting is possible to advance or retard whole ignition curve. When setting is
positive then ignition curve is advanced and when setting is negative than ignition curve is
retarded. With
Advance
0.0deg
, ignition curve is unchanged.
Enter menu and move to
Advance
with pressing + or - and then press enter .