- 5 -
8.
Set POWER JET parameters
Enter menu and move to
Power Jet
with pressing + or - and then press enter .
Now you are in submenu for selecting
Power Jet
parameters.
Submenu organisation:
Power Jet
ON
RPM
- revs for activating power jet
Power Jet OFF
RPM
- revs for deactivating power jet
Power Jet ON
TPS
- throttle position for activating power jet
Exit
- exit submenu
Example:
Power jet ON (RPM) = 8000rpm
Power jet OFF (RPM) = 10000rpm
Power jet ON (TPS) = 90%TPS
Power jet is switched on, when revs are above 8000rpm and throttle position above 90%TPS.
Power jet is switched off, when revs are above 10000rpm or throttle position is below
90%TPS.
8.1.
Set POWER JET ON
RPM
Enter menu and move to
Power Jet 1 ON
RPM
with pressing + or - and then press enter .
Now you can change rev limit with pressing + or - (in 100 rpm steps) and then press
enter .
8.2.
Set POWER JET OFF
RPM
Enter menu and move to
Power Jet OFF
RPM
with pressing + or - and then press enter .
Now you can change rev limit with pressing + or - (in 100 rpm steps) and then press
enter .
8.3.
Set POWER JET ON
TPS
Enter menu and move to
Power Jet ON
TPS
with pressing + or - and then press enter .
Now you can change TPS position with pressing + or - (in 1%TPS steps) and then press
enter .
9.
Set SHIFT KILL TIME
Enter menu and move to
Shift Kill Time
with pressing + or - and then press enter .
Now you can change kill time with pressing + or - (in 10 ms steps) and then press enter .