8. 

Set POWER JET parameters 

 
Enter menu and move to 

Power Jet 

with pressing  +  or  -  and then press  enter  . 

Now you are in submenu for selecting 

Power Jet

 parameters. 

 
Submenu organisation: 

Power Jet

 

ON 

RPM 

 

- revs for activating power jet 

Power Jet OFF 

RPM 

 

- revs for deactivating power jet 

Power Jet ON 

TPS

   

- throttle position for activating power jet 

Exit 

   

 

 

- exit submenu 

 

Example: 

Power jet ON (RPM) = 8000rpm 
Power jet OFF (RPM) = 10000rpm 
Power jet ON (TPS) = 90%TPS 
 
Power jet is switched on, when revs are above 8000rpm and throttle position above 90%TPS.  
Power jet is switched off, when revs are above 10000rpm or throttle position is below 
90%TPS. 

 
 
8.1. 

Set POWER JET ON 

RPM

 

 
Enter menu and move to 

Power Jet 1 ON 

RPM

 

with pressing  +  or  -  and then press  enter  . 

Now you can change rev limit with pressing  +  or  -  (in 100 rpm steps) and then press    

enter  . 

 
 
8.2. 

Set POWER JET OFF 

RPM

 

 
Enter menu and move to 

Power Jet OFF 

RPM

 

with pressing  +  or  -  and then press  enter  . 

Now you can change rev limit with pressing  +  or  -  (in 100 rpm steps) and then press    

enter  . 

 
 

8.3. 

Set POWER JET ON 

TPS

 

 
Enter menu and move to 

Power Jet ON 

TPS

 

with pressing  +  or  -  and then press  enter  . 

Now you can change TPS position with pressing  +  or  -  (in 1%TPS steps) and then press    

enter  . 

 
 
9. 

Set SHIFT KILL TIME 

 
Enter menu and move to 

Shift Kill Time 

with pressing  +  or  -  and then press  enter  . 

Now you can change kill time with pressing  +  or  -  (in 10 ms steps) and then press  enter  . 
 

 

Содержание PCDI-24V

Страница 1: ...from hi voltage charging coils generator programmable ignition map 3D interpolated store and load function for 2 ignition maps one input for magnetic pickup TPS input ignition map is 3D interpolated...

Страница 2: ...g enter Exit menu with selecting Exit 2 MENU ORGANISATION Set Ign set ignition parameters submenu Set PV set PV parameters submenu Exit 2 1 SET IGNITION PARAMETERS SUBMENU Load Ign Curve load previous...

Страница 3: ...tion curve set with pressing or and then press enter 5 Set IGNITION CURVE Three ignition curves must be programmed for different TPS positions PCDI does not only switch between ignition curves but als...

Страница 4: ...th this setting is possible to advance or retard whole ignition curve When setting is positive then ignition curve is advanced and when setting is negative than ignition curve is retarded With Advance...

Страница 5: ...r throttle position is below 90 TPS 8 1 Set POWER JET ON RPM Enter menu and move to Power Jet 1 ON RPM with pressing or and then press enter Now you can change rev limit with pressing or in 100 rpm st...

Страница 6: ...ust set flat ignition curve Then measure with stroboscope lamp if mark at flywheel moving when changing revs If mark moving then you must change compensation delay Change Compensation Enter menu and m...

Страница 7: ...number to which you want to save your ignition curve set with pressing or and then press enter 18 Set PV Curve Enter menu and move to Set PV Curve with pressing or and then press enter Now you are in...

Страница 8: ...ition with pressing or and then press enter Now you can set close position with pressing or and then press enter Max close position is when curve is set to 0 This close position can be moved to any de...

Страница 9: ...TPS position Information You can connect or disconnect PCDI unit from programmer any time you want without any harm It is not important if motor running or not and if power supply is connected or not...

Отзывы: