7 Setting Up the Scanner
In certain cases no setup is required. The scanner is either pre-programmed to
suit the situation, or it automatically detects and is ready to go. In other cases
the scanner must be informed about what kind of system it is connected to.
This can be done in a few moments using the programming barcodes in the
Programming Guide.
The programming section may be used to set a number of parameters on the
scanner: communication interface type (RS-232, Keyboard, USB), beep tone,
sleep mode timings, same-code delay time, enable/disable decoding of
numerous code types, and more advanced settings like set headers and trailers.
Individual parameters may be set at any time without affecting the other
parameters.
7.1 Scan Test
1. With the scanner running (blue LED lights) and the host system on, try to
scan several known-good barcodes.
2. Check the results on the POS screen. If the scanner is reading okay, it is
likely that no further setup is necessary.
3. If the POS screen does not show the expected scans, go to the Set Up
section below.
7.2 Set Up
1. When the scanner is powered on (blue LED lights), find the <Enter/Exit
programming mode> barcode in the Programming Guide and present this
barcode to the scanner. When the scanner gives two beeps (one low and
one high) and the LED turns red, it means the scanner is in programming
mode.
2. Decide which parameters are required and find their barcodes in the
Programming Guide.
3. Cover unwanted codes with your hand and present the desired codes, one
by one, to the scanner; the scanner beeps once as it accepts each code.
4. When done, again present the <Enter/Exit programming mode> barcode.
The scanner beeps twice, once long and once short, and the LED returns to
blue. The scanner has been programmed.
5. Test again with known-good barcodes. If results are good, you are done
setting up. Otherwise, return to step 1 and try again.