background image

U

SER

M

ANUAL

 

Wireless Handheld Gun Type Scanner 

83 

 

Start Of Configuration 

 

Full ASCII Code 39 Table 

Code 39 

ASCII 

Hexa

-

code

Code 39 

ASCII 

Hexa-

code

 

Full ASCII ---NUL 

00 

 

Full ASCII ---SI 
Function key-----“Shift”

0F 

 

Full ASCII ---SOH 
Function key-----“Ins” 

01 

 

Full ASCII ---DLE 
Function key-----
“5(num)” 

10 

 

Full ASCII ---STX 
Function key-----“Del” 

02 

 

Full ASCII ---DC1 
Function key-----“F1” 

11 

 

Full ASCII ---ETX 
Function key-----“Home” 

03 

 

Full ASCII ---DC2 
Function key-----“F2” 

12 

 

Full ASCII ---EOT 
Function key-----“End” 

04 

 

Full ASCII ---DC3 
Function key-----“F3” 

13 

 

Full ASCII ---ENQ 
Function key-----“Up 
arrow” 

05 

 

Full ASCII ---DC4 
Function key-----“F4” 

14 

 

Full ASCII ---ACK 
Function key-----“Down 
arrow” 

06 

 

Full ASCII ---NAK 
Function key-----“F5” 

15 

 

Full ASCII ---BEL 
Function key-----“Left 
arrow” 

07 

 

Full ASCII ---SYN 
Function key-----“F6” 

16 

 

Full ASCII ---BS 
Function key-----
“Backspace” 

08 

 

Full ASCII ---ETB 
Function key-----“F7” 

17 

 

Full ASCII ---HT 
Function key-----“TAB” 

09 

 

Full ASCII ---CAN 
Function key-----“F8” 

18 

 

Full ASCII ---LF 
Function key-----“Enter 
(alpha numeric)” 

0A 

 

Full ASCII ---EN 
Function key-----“F9” 

19 

 

Full ASCII ---VT 
Function key-----“right 
arrow” 

0B 

 

Full ASCII ---SUB 
Function key-----“F10” 

1A 

 

Full ASCII ---FF 
Function key-----“PgUp” 

0C 

 

Full ASCII ---ESC 
Function key-----“F11” 

1B 

 

Full ASCII ---CR 
Function key-----
“Enetr(num.)” 

0D 

 

Full ASCII ---FS 
Function key-----“F12” 

1C 

 

Full ASCII ---SO 
Function key-----“PgDn” 

0E 

 

Full ASCII ---GS 
Function key-----“ESC” 

1D 

 

End Of Configuration 

Содержание Z-3191BT

Страница 1: ...Advanced Handheld High Speed Laser Scanner 1...

Страница 2: ...sion 1 0 August 24 2011 Initial release 1 1 March 26 2012 Added wireless communication tips 1 2 April 18 2012 Added cable clip installation and Smart Phone Software Keypad Control Setting 1 3 May 24 2...

Страница 3: ...ical biological manual or otherwise except for brief passages which may be quoted for purposes of scholastic or literary review without express written consent and authorization We reserve the right t...

Страница 4: ...acturer and authorized dealer or experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commission helpful Ho...

Страница 5: ...rd Optical instruments include binoculars magnifying glasses and microscopes but do not include normal eye glasses worn by the user CAUTION Use of controls or adjustments or performance of procedures...

Страница 6: ...nd other wireless devices in the following locations as it may cause an accident Where inflammable gas is present in a hospital train airplane or a petrol station Near automatic doors or a fire alarm...

Страница 7: ...also use this frequency If you use these wireless devices in your office your device might not be able to hear the signals over the noise coming from them If your network uses wireless G you can quiet...

Страница 8: ...n the Scanner 9 How to Scan 10 Radio Communication Host Type 11 Cradle Host Mode 11 SPP Mater SPP Slave Mode 11 HID Mode 11 Paging the Scanner 12 Scanner USB online to Host 12 USB Online Mode 12 Visib...

Страница 9: ......

Страница 10: ...to the connected host in a 100 meter connection range in open space or 75 meter range in indoor environments the actual communication range may vary due to different indoor placement This feature elim...

Страница 11: ...Scanner 2 Product Overview Scanner LED Indicator Exit Window Buzzer Metal Charging Contacts Trigger Strap Hole Cradle Function Trigger LED indicator Charging Contacts Host Connector DC Power Connector...

Страница 12: ...ith battery Scanner cradle optional with cradle without cradle Li ion battery pack Communication cable for cradle optional Mini USB B to mini USB A cable 5V USB Power adapter CD ROM or handbook Contai...

Страница 13: ...tall the batteries Always use the rechargeable batteries provided by the manufacturer to avoid any non compatible danger or void the warranty 1 Unscrew the cap from the battery compartment at the bott...

Страница 14: ...lip you can easily transform your wireless scanner into a wired one Attaching Cable Clip 1 Insert the cable clip to the strap hole as shown 2 Gently turn the cable clip counter clockwise and push the...

Страница 15: ...e cable from the clip and detach the bottom part of the cable clip from the scanner handle 2 Unhook the left part of the cable clip from the strap hole then turn it clockwise While in turning motion p...

Страница 16: ...the bottom of the cradle and connect other end to USB power adaptor 3 Connect the USB power adaptor into AC outlet The LED indicator on the cradle should flash blue until it made connection with the...

Страница 17: ...arging when the scanner LED indicator starts flashing green LED turns steady green when charging is complete Approx charging time 4 5 hours To charge the battery using the USB cable There are two meth...

Страница 18: ...ot be full charged and should be fully charged for maximum charge capacity z Recommended charging environment is temperature in 0 C 35 C 32 F 95 F Power on the Scanner 1 Ensure the battery is fully ch...

Страница 19: ...Power on the scanner 2 Press the trigger and aim at the barcode as illustrated 3 When decoding is successful the scanner beeps and the LED indicates blue Presentation Scanning 1 Put the scanner into...

Страница 20: ...e same delivery box are paired in factory As soon as both are powered on they should find and connect to each other immediately However under special circumstance that the scanner and the cradle are n...

Страница 21: ...function trigger beep sounds and blue LED flash 3 times if it is in range Scanner USB online to Host The sc en the radio communication is not available the scanner can be connected to transmit data v...

Страница 22: ...r ra io connection flash time 0 5s 0 5s d Blue fast Flashing Radio connecting Blue Slow Flashing evice connect 0 03s 3s D ed flash time 1 Blue Flashing A barcode was decoded successfully Blue Fast Fla...

Страница 23: ...o disconnected Sound Indicators When the scanner is in operation it provides audible feedback The beeps indicate the status of the scanner Beep Indication A long beep Power on scanner One beep A barco...

Страница 24: ...in the data protocol or packing could confirm the data reliability Refer to below for different setting options a No ACK NAK protocol b ACK NAK only c Frame packing BT Scanner Remote BT device BT sca...

Страница 25: ...sulated data length excluding header character Format Byte FEH Differentiate data format barcode data is always FEH Data ID The number of each data If receive the same ID more than once only the first...

Страница 26: ...ld Gun Type Scanner 17 USER S MANUAL Barcode Type Table Code Value Code39 0x11 Codabar 0x01 Code128 0x03 Interleaved 2 5 0x02 Code93 0x06 UPC E 0x14 UPC A 0x24 EAN 8 0x34 EAN 13 0x44 Chinese Post Code...

Страница 27: ...IN 1 5V PIN 2 USB_D PIN 3 USB_D PIN 4 NC PIN 5 GND Cradle Phone Jack Pin Out Configuration RJ 1 RTS_EIA RJ 6 RX_ EIA RJ 2 KB Data USB_D RJ 7 KB Clock RJ 3 PC Clock USB_D RJ 8 5V RJ 4 GND RJ 9 PC Data...

Страница 28: ...B Data 2 N C 2 N C 3 GND 3 GND 4 5V 4 5V 5 PC Clock 5 KB Clock 6 N C 6 N C 2 RS 232 Cable DTE pin out PIN OUT CONFIGURATION DB 9 F FUNCTION 2 TX 3 RX 7 CTS 8 RTS 5 GND 3 RS 232 Cable DCE pin out PIN O...

Страница 29: ...barcode and save the new configuration 5 To give up a configuration change power off the scanner before scanning the End of Configuration barcode or scan the Abort barcode 6 For some parameter setting...

Страница 30: ...Default Radio communication Wireless host Cradle Host Pairing mode Unlocked Data transmit Normal Radio protocol timeout 5 seconds Power off timeout 20 minutes Encryption Enable Cradle Host RS 232 comm...

Страница 31: ...cy Medium Duration Medium Operating Parameter Default Scan mode Trigger mode Stand mode Enable Header and trailer None Inter message delay None Inter character delay None Code Identifiers Default Iden...

Страница 32: ...nded identifier code RX Default Data Transmit Format Code Message format EAN 13 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 EAN 8 D1 D2 D3 D4 D5 D6 D7 D8 UPCA D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 UPC...

Страница 33: ...charge and transmit data You may enable or disable the functions using the following settings Disable USB communication USB online scan disable Disable USB communication Enable USB communication USB o...

Страница 34: ...o another scanner so you must unpair the scanner before continuing 2 Power on the scanner and enable cradle host mode if necessary Cradle Host mode enable Enable cradle mode with this set 3 Use the sc...

Страница 35: ...ls for pairing instructions To connect a wireless device to Window based system for the first time 1 Turn on the host computer and activate its wireless connection 2 Select Add wireless device Or open...

Страница 36: ...eless address SPP Master only Set wireless address for SPP Master connection 4 Use the ASCII table in Programming Guide to input the 12 digit wireless address For example if the address is 011B1345600...

Страница 37: ...wireless HID keyboard emulation Smart phone mode For smart phone mode BT HID MODE must also be enabled 2 Enable wireless connection on your host and follow the instructions in your host to set it to...

Страница 38: ...Setting to store the pin code Set pin code Set pin code SPP Master only Confirm Setting for address and pin code setting required Please check the User s Manual from your PC for wireless address and p...

Страница 39: ...uide to input the name Max 12 digits 3 Scan Confirm Setting to store the new name Friendly device name set Change the display name when scanner is discovered Confirm Setting for address and pin code s...

Страница 40: ...range the scanned data will be transferred to the host computer immediately If the scanner is out of its connecting range the scanner does not send or store any data Data transmit normal Batch mode is...

Страница 41: ...he bar code 2 Batch mode Note Scanner LED indicator will not flash while waiting for connection in this mode Clearing Batch Use the settings in this section to clear the stored data Clear batch data a...

Страница 42: ...cradle Data is ready to be transferred upon placement on the cradle Press and hold the trigger for over 1 second to send the data Cradle radio connected is required Batch Mode Sounds Settings Use the...

Страница 43: ...rn cradle host to factory defaults Return to USB default Communication cradle link required Return to wand emulation default Communication cradle link required Return to RS232 default Communication cr...

Страница 44: ...scan mode The scanner is still active after the data is transmitted but the successive transmission of the same barcode is not allowed when the trigger switch is pressed again Alternate mode The scann...

Страница 45: ...is mode the scanner can not pair with another cradle Undo pairing Undo the pairing between the cradle and the scanner Scanner On Cradle sound alert enable Enable beep sound alert when scanner is place...

Страница 46: ...scan Ignore radio communication BT HID mode BT HID mode Combo keyboard For Apple mode Must execute BT HID mode first SPP Master Slave mode Scanner SPP Master enable SPP Master Connect wireless address...

Страница 47: ...e pin code Confirm Setting for address device name and pin code setting required Required Pair with slave SPP Master Discover enable Discover disable Encryption enable Encryption disable Data communic...

Страница 48: ...atch Data By Scanning Label Clear batch data after send Clear batch data by scanning Delete batch data label Delete batch data Send Batch Data on line USB cable contact Send Batch data on cradle Out o...

Страница 49: ...ion Radio protocol communication parameter Radio protocol timeout 3 sec Radio protocol timeout 5 sec Radio protocol timeout 8 sec Radio protocol timeout 10 sec Radio protocol timeout 13 sec Radio prot...

Страница 50: ...ation Power off timeout parameter Power off timeout 5 min Power off timeout 10 min Power off timeout 20 min Power off timeout 30 min Power off timeout 1 hr Power Off timeout 2 hr Power Off timeout 4 h...

Страница 51: ...Scanner 42 Start Of Configuration Power Always On Power off by scanning this label Link beeper enable Link beeper disable Power up beeper enable Power up beeper disable Same Code Delay 50 msec 100 mse...

Страница 52: ...USER S MANUAL Wireless Handheld Gun Type Scanner 43 Start Of Configuration 400 msec 500 msec 600 msec 700 msec 800 msec 1000 msec Infinite End Of Configuration...

Страница 53: ...AL Wireless Handheld Gun Type Scanner 44 Start Of Configuration Operation Function Setting Good Read Beeper Tone Selection Medium beeper tone High beeper tone Low beeper tone Speaker disable End Of Co...

Страница 54: ...USER S MANUAL Wireless Handheld Gun Type Scanner 45 Start Of Configuration Beeper duration Selection Long Medium Short Ultra Short Ultra Long End Of Configuration...

Страница 55: ...brator enable Good read vibrator disable Good read beeper and vibrator enable Vibration duration 100msec Vibration duration 200msec Vibration duration 300msec Vibration duration 400msec Vibration dura...

Страница 56: ...USER S MANUAL Wireless Handheld Gun Type Scanner 47 Start Of Configuration Inter Character Delay 0 ms 2 ms 5 ms 10 ms 20 ms 50 ms Inter Message Delay 0 ms 100 ms 500 ms 1000 ms End Of Configuration...

Страница 57: ...f Configuration Interface Settings 1 RS 232C Interface Setting Baud Rate 115200 19200 9600 4800 2400 1200 Parity Bit Even parity Odd parity Mark parity Space parity None parity Stop Bit 1 stop bit 2 s...

Страница 58: ...ing ACK NAK Xon Xoff RTS CTS Enable BEEPER ON BEL CHARACTER Ignore Beep on BEL character ACK NAK response time 300ms ACK NAK response time 2 sec ACK NAK response time 500 ms ACK NAK response time 3 se...

Страница 59: ...guration Message Terminator RS 232 message terminator none RS 232 message terminator CR LF RS 232 message terminator CR RS 232 message terminator LF RS 232 message terminator H tab RS 232 message term...

Страница 60: ...language support GERMANY Keyboard language support FRENCH send scan code Keyboard language support SPANISH send scan code Keyboard language support ITALIAN send scan code Keyboard language support Sw...

Страница 61: ...USER S MANUAL Wireless Handheld Gun Type Scanner 52 Start Of Configuration Message Terminator Keyboard terminator none Keyboard terminator Enter Keyboard terminator H TAB End Of Configuration...

Страница 62: ...od Keyboard language support USA Keyboard language support GERMANY Keyboard language support FRENCH send scan code Keyboard language support SPANISH send scan code Keyboard language support JAPANESE K...

Страница 63: ...symbology Enable Wand output data format as CODE39 Wand emulation data output black high y Scan this bar code to set quiet zones and spaces low and bars high Wand emulation data output black low y Sc...

Страница 64: ...narrow element width Wand emulation speed medium y This option allows the transmission of wand emulation at 600us narrow element width Wand emulation speed high y This option allows the transmission...

Страница 65: ...ion enable or disable Software keypad To enable disable Software keyboard 1 Scan the Start Of Configuration barcode 2 Scan the Multi media keyboard mode barcode 3 Scan the End Of Configuration barcode...

Страница 66: ...5 Codabar start stop character transmission none CB06 Codabar start stop character transmission A B C D CB07 Codabar start stop character transmission DC1 DC4 CB08 Codabar start stop character transmi...

Страница 67: ...ode Label Description CB13 No check character CB14 Validate modulo 16 but don t transmit CB15 Validate modulo 16 and transmit DC50 Codabar data redundant check off DC51 Codabar data redundant check 1...

Страница 68: ...de 39 disable RC13 Code 32 enable RD13 Code 32 disable DC00 Code 39 data redundant check off DC01 Code 39 data redundant check 1 DC02 Code 39 data redundant check 2 DC03 Code 39 data redundant check 3...

Страница 69: ...Code 39 check digit calculate but without transmit 3907 No check character 3908 Code 39 maximum length setting 3909 Code 39 minimum length setting SET Confirm to save this setting required for reading...

Страница 70: ...a redundant check 1 DC32 Code 93 data redundant check 2 DC33 Code 93 data redundant check 3 9301 Code 93 maximum length setting 9302 Code 93 minimum length setting SET Confirm to save this setting req...

Страница 71: ...able DC40 Code 128 data redundant check off DC41 Code 128 data redundant check 1 DC42 Code 128 data redundant check 2 DC43 Code 128 data redundant check 3 1803 No check character 1804 Calculate but no...

Страница 72: ...code disable DC60 Chinese post code data redundant check off DC61 Chinese post code data redundant check 1 DC62 Chinese post code data redundant check 2 DC63 Chinese post code data redundant check 3 S...

Страница 73: ...ing MS02 MSI Plessy minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting MS03 MSI Plessy double check digit calculate but not transmit MS04...

Страница 74: ...1102 Code 11 minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting 1103 Code 11 one check digit verification 1104 Code 11 two check digit ve...

Страница 75: ...RD04 ITF 2 of 5 disable RC09 IATA code enable RD09 IATA disable DC80 ITF 25 data redundant check off DC81 ITF25 data redundant check 1 DC82 ITF25 data redundant check 2 DC83 ITF25 data redundant check...

Страница 76: ...IT01 ITF 2 of 5 code maximum length setting IT02 ITF 2 of 5 code minimum length setting IT06 ITF 2 of 5 one fixed length setting IT07 ITF 2 of 5 two fixed length setting SET Confirm to save this sett...

Страница 77: ...f 5 code disable D051 Standard 2 of 5 code maximum length setting D052 Standard 2 of 5 code minimum length setting SET Confirm to save this setting required for reading full ASCII table and length set...

Страница 78: ...code disable D251 Industrial 2 of 5 code maximum length setting D252 Industrial 2 of 5 code minimum length setting SET Confirm to save this setting required for reading full ASCII table and length se...

Страница 79: ...AN convert to ISSN ISBN enable RD11 EAN convert to ISSN ISBN disable RC03 UPC EAN JAN enable RD03 UPC EAN JAN disable UE01 UPC EAN JAN all enable UE02 EAN 8 or EAN 13 enable UE03 UPC A and EAN 13 enab...

Страница 80: ...disable UE15 Force UPC A to EAN 13 format enable UE16 Force UPC A to EAN 13 format disable UE44 Force EAN 8 to EAN 13 format enable UE45 Force EAN 8 to EAN 13 format disable UE17 Transmit UPC A check...

Страница 81: ...it disable UE27 Transmit UPC A leading character enable UE28 Transmit UPC A leading character disable UE30 Add on format with separator UE31 Add on format without separator UE60 EAN 13 country code fi...

Страница 82: ...t check 1 DC16 UPC E data redundant check 2 DC17 UPC E data redundant check 3 DC20 EAN 13 data redundant check off DC21 EAN 13 data redundant check 1 DC22 EAN 13 data redundant check 2 DC23 EAN 13 dat...

Страница 83: ...t requirement not sent for other UE38 EAN UPC addon mandatory for 978 977 bookland Supplement requirement optional for other UE42 EAN UPC addon mandatory for 491 Japanese bookland Supplement requireme...

Страница 84: ...Gun Type Scanner 75 Start Of Configuration 12 Telepen Parameter Setting Barcode Value Barcode Label Description RC25 Telepen enable RD25 Telepen disable TE03 Telepen numeric mode enable TE04 AIM Tele...

Страница 85: ...12 Matrix 2 of 5 disable D151 Matrix 2 of 5 maximum length setting D152 Matrix 2 of 5 minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting D...

Страница 86: ...Formally RSS Limited GS1 DataBar Limited Group 3 GS1 DataBar Expanded Formally RSS Expanded GS1 DataBar Expanded GS1 DataBar Expanded Stacked GS1 DataBar Omnidirectional Formally RSS 14 Barcode Value...

Страница 87: ...Value Barcode Label Description RC16 GS1 DataBar Limited enable RD16 GS1 DataBar Limited disable SS10 Transmit GS1 DataBar Limited check digit SS11 Don t transmit GS1 DataBar Limited check digit SS12...

Страница 88: ...panded enable RD17 GS1 DataBar Expanded disable SS07 GS1 DataBar Expanded EAN 128 emulation enable SS06 GS1 DataBar Expanded EAN 128 emulation disable SS08 GS1 DataBar Expanded check digital enable SS...

Страница 89: ...d IS03 Enable identifier code table as AIM standard CI01 Code 39 identifier code setting CI02 ITF 2 of 5 identifier code setting CI03 Chinese Post Code identifier code setting CI04 UPC E identifier co...

Страница 90: ...de setting CI12 GS1 DataBar Omnidirectional identifier code setting CI13 GS1 DataBar Limited identifier code setting CI14 GS1 DataBar expanded identifier code setting CI15 Industrial 2 of 5 identifier...

Страница 91: ...Description CP11 Add code length as header enable 2 digits CP12 Add code length as header disable 2 digits HT01 Header Preamble HT02 Trailer Postamble HT03 Truncate header character HT04 Truncate trai...

Страница 92: ...Full ASCII DC4 Function key F4 14 Full ASCII ACK Function key Down arrow 06 Full ASCII NAK Function key F5 15 Full ASCII BEL Function key Left arrow 07 Full ASCII SYN Function key F6 16 Full ASCII BS...

Страница 93: ...y ALT L 1F Full ASCII 2E Full ASCII SP 20 Full ASCII 2F Full ASCII 21 Full ASCII 0 30 Full ASCII 22 Full ASCII 1 31 Full ASCII 23 Full ASCII 2 32 Full ASCII 24 Full ASCII 3 33 Full ASCII 25 Full ASCII...

Страница 94: ...SCII 3E Full ASCII M 4D Full ASCII 3F Full ASCII N 4E Full ASCII 40 Full ASCII O 4F Full ASCII A 41 Full ASCII P 50 Full ASCII B 42 Full ASCII Q 51 Full ASCII C 43 Full ASCII R 52 Full ASCII D 44 Full...

Страница 95: ...ASCII 5C Full ASCII k 6B Full ASCII 5D Full ASCII l 6C Full ASCII 5E Full ASCII m 6D Full ASCII _ 5F Full ASCII n 6E Full ASCII 60 Full ASCII o 6F Full ASCII a 61 Full ASCII p 70 Full ASCII b 62 Full...

Страница 96: ...7 Start Of Configuration Full ASCII Code 39 Table continued Code 39 ASCII Hexa code Code 39 ASCII Hexa code Full ASCII x 78 Full ASCII 7C Full ASCII y 79 Full ASCII 7D Full ASCII z 7A Full ASCII 7E Fu...

Страница 97: ...enable USB virtual COM port 1 Connect the handheld scanner and the host e g a PC with a USB interface cable 2 Enable USB virtual COM port with programming barcode on page 32 3 After the programming th...

Страница 98: ...t Example If the barcode length is 4 to 12 digits the steps would be as below End Set up barcode length Start Set up minimum barcode length Start of Configuration Set up maximum barcode length End of...

Отзывы: