Zeagle Defender EBS 310 Скачать руководство пользователя страница 11

Page

 1

1

 

Filler Adapter Assembly (includes Male QD Connector) is available 

from Zeagle. 

Part Number

330-9420

.  Note: Fill Adapter DIN connection option for attaching to the HP supply is acceptable The

yoke type (CGA) connector option is limited to a maximum pressure of 232 bar (3364 PSI) and is not
suitable for greater pressure required to fully charge the cylinder.

  Do not expose a Yoke type (CGA) Fill Adapter to a pressure greater than 232 bar 

 (3364 PSI).  It is not rated for the higher pressure and could lead to damage exposing the operator to 
the risk of serious or death. 

  

Do not

 attempt to 

fill 

the EBS cylinder with 

any gas other than clean air

 that 

conforms to EN12021 or the equivalent CGA Grade E standard. Introduction of other gases including 
Enriched Air Nitrox (EAN) is prohibited.  Handling of oxygen- enriched air requires specialized 
treatment of involved equipment and if not performed properly, could create a hazard with a possible 
risk of serious injury or death. 

Before connecting the Fill Adapter to the Male QD observe the following information. 

When compressed air is introduced into the cylinder heat is generated.  The amount of heat is related 
to how rapidly the cylinder is filled. In order to prevent overheating the cylinder the fill rate must be 
limited. 

Composite cylinders such as that used with the EBS can tolerate a limited amount of heat exposure if 
they are well maintained and undamaged, but the presence of heat interferes with reaching the full 
volumetric capacity of the cylinder at 310 bar with the cylinder at 21°C (70°F) 

If the cylinder is filled to 310 bar at a higher temperature, after filling has stopped and the cylinder cools, 
the pressure will reduce and the charge will not be at full capacity.  Slow filling is preferred and is 
limited to a recommended rate of not greater than 28 bar (400 PSI) per minute. This will greatly reduce 
the generation of heat and will require about 11 minutes to reach full capacity.  

ZE.01.05.0030 REV. A

EBS 

User

 

Manual

Содержание Defender EBS 310

Страница 1: ...Page 1 ZE 01 05 0030 REV A EBS User Manual...

Страница 2: ...Page 2 ZE 01 05 0030 REV A EBS User Manual...

Страница 3: ...EBS is considered a Emergency Self Contained Emergency Underwater Breathing Apparatus A such the EBS is designed for user deployment and operation with sufficient notice given to the user to deploy t...

Страница 4: ...able ease of use and maintenance Additional features that include adjustable mouthpiece positions a flexible hose with swivel connections and convenient port connections provide desirable options for...

Страница 5: ...his manual and mastering the skills necessary to operate inspect and maintain it properly Failure to do so could result in a situation whereby the EBS would not be an available resource to assist with...

Страница 6: ...regulator and valve is threaded into the cylinder to provide a compact assembly It is provided with an onboard pressure gauge an ON OFF port fill port and low pressure hose with a swivel connection at...

Страница 7: ...anual EBS User Manual ZE 01 05 0030 REV A The ON OFF port of the integrated valve and first stage must always be in the ON position any time the EBS is in service and ready to be deployed If the valve...

Страница 8: ...the EBS incapable of delivering air to the user EBS SECOND STAGE REGULATOR The second stage regulator with an integrated mouthpiece is connected to the first stage by means of a flexible hose with a s...

Страница 9: ...NCY SITUATION 1 Use one hand to secure your position at the nearest exit escape route Use your free hand to grasp the EBS second stage regulator and pull out and away from your body to ensure hose is...

Страница 10: ...air flow ceases allowing you to comfortably exhale Air flow to you can be manually activated anytime by pressing the purge feature as long as there is a remaining air supply in the cylinder 5 After y...

Страница 11: ...properly could create a hazard with a possible risk of serious injury or death Before connecting the Fill Adapter to the Male QD observe the following information When compressed air is introduced in...

Страница 12: ...e a full charge Exceeding the maximum pressure and fill rate could result in damage to the EBS and create a hazardous condition with the possibility of serious injury or death To Fill the EBS cylinder...

Страница 13: ...freshwater to remove sea salt and other contaminates Be sure mouthpiece and exhaust valves are included in flushing operation Following rinsing dip the second stage in a sanitizing bath as prescribed...

Страница 14: ...authorized facility for compliance with ISO11623 at five year intervals from the certification date appearing on the cylinder label Further the cylinder must be taken out of service if it has been ex...

Отзывы: