Technical specifications
Technical specifications
20 KTL
25 KTL
30 KTL
33 KTL
Input (DC)
Typical power of PV system
26000W
32500W
39000W
42900W
Maximum DC power for each
MPPT
13000W
16000W
18000W
20000W
Number of independent
MPPTs
2
Number of DC inputs
2 for each MPPT
3 for each MPPT
Maximum DC input voltage
1100V
Input activation voltage
250V
Rated DC input voltage
620V
MPPT DC voltage range
230V - 950V
DC voltage range at full load
480V-850V
460V-850V
520V-850V
580V-850V
Max input DC current for each
MPPT
24A/24A
28A/28A
30A/30A
30A/30A
Output (AC)
Rated AC output power
20000W
25000W
30000W
33000W
Maximum AC power
22000VA
27500VA
33000VA
36300VA
Maximum AC current
32A
40A
48A
53A
Rated AC voltage
3F/N/PE,230/400V (+/- 20%)
Rated AC voltage range
180V-270V (According to local grid standards)
Grid frequency
50 / 60 Hz (According to local grid standards)
Grid frequency range
45-53Hz / 57-63 Hz (According to local grid standards)
Active power adjustable range
0-100%
Total harmonic current
distortion
<3
%
Power factor
1 (adju/-0.8)
Grid feed limit
Feed adjustable from zero to nominal value (ARPC required)
Operating performance
Maximum efficiency
98.2%
98.4%
98.6%
Weighted efficiency (EURO)
98%
98.2%
Consumption at night
<1W
MPPT efficiency
>99.5%
Protection
Reverse polarity protection
Yes
Overheating protection
Yes
DC circuit breaker
Integrated
Protection class / Overvoltage
category
I/III
Integrated dischargers
AC/DC MOV: Type III Standard
Safety protection
Anti-islanding, RCMU, Ground leakage monitoring