Grounding the External Antenna
If you decide to place the External Antenna outdoors, it must be properly grounded. (See page iv for
a recommended grounding kit).
The set up must be in accordance with Article 810 of the National Electric Code (NEC). A listed
antenna discharge unit must be provided for the lead-in coaxial cable per NEC article 8.10.20 or
the shield of the coaxial cable must be permanently and effectively grounded in accordance with
NEC article 8.10.21. Please consult a professional installer or electrician for more information. (See
page v).
Securing Cable with a Drip Loop
If you place the External Antenna outdoors, create a drip loop
with the coaxial cable at the point where the cable enters the
home through an outside wall. This can be done by twisting and
securing the cable into a loop (no less than 4” across) near the
entry point. This will help prevent moisture from gathering at entry
point and leaking into the home. Consult a professional installer if
you need more information.
Power Requirements
The Base Unit can be plugged into a standard 2 or 3 prong 110 VAC receptacle using the Included
power supply. The power supply consumes less than 10W (less than 0.2A).
Warning
The zBoost ZB560Y Cellular REACH base unit MUST
only be used with the provided power adaptor. Use of
other power adaptors will void the warranty and may
damage the unit. Use of other equipment is not FCC
approved.
Coax Cable
Exterior Wall
Note
Avoid placing the External Antenna near metal such as
wiring, A/C ducts, metal siding, truss plates, etc.
When connecting the cable to the antenna, run the
cable straight down from the antenna. Avoid draping
the coax near the antenna.