background image

RSS-14 

 

Read:

 Format 

 

Data Digits 

(Variable) 

Checksum1

(Optional) 

Max./Min. code length: 

Refer to Max./Min. code length of 

Code-39. 

Truncate leading/ending: 

Refer to Truncate leading/ending 

of UPCA. 

Code Id setting: 

Refer to Code ID setting of UPCA. 

Insertion group selection: 

Refer to

 

Insertion group 

selection of UPCA. 

UCC/EAN 128 emulation: 

Refer to Transmission (P89), 

Code ID transmission must be set as AIM ID enable. 
Then ]C1 will be identified as prefix of barcode data 
transmission. 

 

 

 

 

 Program

 

Option Bar Code 

Option 

Alphanumeric 

Entry 

Read 

Disable 

Enable 

00

 

01 

Max. code length   

00-64 00-64 

64

 

Min. code length   

00-64 00-64 

01

 

 

69

Содержание ZB-8150

Страница 1: ...ZB 8150 ZB 8110 ZB 8210 CCD BARCODE SCANNER User s Manual ZBA Inc 94 Old Camplain Road Hillsborough NJ 08844 Phone 908 359 2070 Fax 908 359 1272 Web http www zbausa com 1...

Страница 2: ...the PC 2 Connect the Scanner cable to the PC 3 Plug the power supply to the scanner 4 Plug the power pack into power source 5 Turn on PC You are ready to use the scanner USB with HID Keyboard Interfa...

Страница 3: ...UPC A V V V V A UPC E V V V V E EAN 13 V V V V F EAN 8 V V V V FF Code 39 V V Interleaved 2 of 5 V V V i Industrial 2 of 5 i Matrix 2 of 5 B Codabar V Code 128 V V V Code 93 V Code 11 V One digit O MS...

Страница 4: ...Width 80 mm 120 mm Scan Speed 50 scans sec 200 scans sec Resolution 0 125mm 5mils Code39 PCS 45 on contact 0 1mm 4mils Code39 PCS 90 Print Contrast 30 or more Scanning Angle Front 60 Rear 60 Yaw 75 D...

Страница 5: ...tandby 240 mW 600 mW Current Operating 76 mA 5 VDC 255 mA 5 VDC Current Standby 48 mA 5 VDC 120 mA 5 VDC DC Transformers Class 2 5VDC 450 mA Agency listing UL FCC Class A Environmental Operating Tempe...

Страница 6: ...cteristics Code type selection check digit selection Decoding option Decoding option Transmitted character delay Header selection trailer selection message suffix good read beep tone and volume scanne...

Страница 7: ...1 Scan the Program barcode on the parameter setting part 2 Enter the option mode by scanning the Option Bar Code also on the Parameter setting part 3 To the right of the option barcode the necessary a...

Страница 8: ...lphanumeric Entry Interface selection Keyboard Wedge RS 232 Wand emulation USB Keyboard RS 232 Auto detection reserved 00 01 02 03 04 05 Back Fold Out Finish barcode Exit Barcode Option Barcode Progra...

Страница 9: ...interface default for other type interface By plugging different cables setting right interface then the scanner will be changed to another interface However you must make sure which cable you need K...

Страница 10: ...rocess without any changes of software or hardware Keyboard Type Select keyboard type connector of your host computer Scanner must be selected to the appropriate host interface cable converter Program...

Страница 11: ...working high speed If some output characters of barcode have been lost you may need to set 05 or 06 to match your host keyboard speed Function Key Set Enable scanner can output code as pressing functi...

Страница 12: ...Spanish Swedish Switzerland UK Latin American 00 01 02 03 04 05 06 07 08 09 10 11 Keyboard speed 0 8 0 high clock rate 8 low clock rate 00 08 01 Function key Disable Enable 00 01 Numeric key Alphabeti...

Страница 13: ...eyboard timing and pass keyboard present status to the PC during power on Inter character delay This delay is inserted after each data characters transmitted If the transmission speed is too high the...

Страница 14: ...ar Code Option Alphanumeric Entry Caps lock Caps lock ON Caps lock OFF 00 01 Power on simulation Disable Enable 00 01 Inter character delay 00 99 msec 00 99 02 Block transmission delay 00 99 10 msec 0...

Страница 15: ...canner will issue a 5 warning beeps Xon Xoff When the host computer is unable to accept data it sends a Xoff code to inform the scanner to suspend data transmission and Xon to continue ACK NAK When th...

Страница 16: ...de Option Alphanumeric Entry Flow control None RTS CTS Xon Xoff ACK NAK 00 01 02 03 Inter character delay 00 99 msec 00 99 00 Block transmission delay 00 99 10 msec 00 99 00 Response delay 00 99 100 m...

Страница 17: ...ion Alphanumeric Entry Baud rate 300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS 00 01 02 03 04 05 06 07 Parity None Odd Even 00 01 02 Data bit 8 bits 7 bits 00 01 Stop bit One...

Страница 18: ...low voltage level 0V and space as high level 5 Initial polarity You must make sure what is Initial polarity of your wand decode device in stand by idle So initial signal state as a High voltage level...

Страница 19: ...ace zone of barcode label margin The width of margin time will be added before and after in each barcode data automatically when it is transmitted Transmit delay It is a delay time between barcode dat...

Страница 20: ...Reserved 00 Reserved 00 Margin delay 00 99 10 pixel 00 99 15 Transmit delay 00 99 10 msec 00 99 30 Exit 20...

Страница 21: ...ger button must be pressed to activate scanning and scanner stops scanning when no code is decoded after the Stand by duration elapsed Continue The scanner always keeps reading and it does not matter...

Страница 22: ...ric Entry Scanning mode Good read off Momentary Alternate Timeout off Continue 00 01 02 03 04 Stand by duration 01 99 second 00 99 10 Same barcode delay time 01 99 10 msec 01 99 50 Double confirm 00 9...

Страница 23: ...ce the fixed length barcode decoded The values of setting have no effect on certain symbologies with fixed length Notes 1 Please set the min max length if you have special demand for individual barcod...

Страница 24: ...00 63 00 63 04 Global max code length 00 63 04 63 63 Inverted image scan Disable Enable 00 01 CTS trigger Disable Enable 00 01 Position indication Disable 30 second 60 second 90 second 120 second 150...

Страница 25: ...nner will light up to indicate a good barcode reading Buzzer indication After each successful reading the scanner will beep buzzer to indicate a good barcode reading and its Beep loudness Beep tone fr...

Страница 26: ...meric Entry Power on alert Disable Enable 00 01 LED indication Disable Enable 00 01 Buzzer indication Disable Enable 00 01 Beep loudness 00 07 00 07 07 Beep tone freq 00 99 100Hz 00 99 26 Beep tone du...

Страница 27: ...igits is 15 Code ID setting Code ID setting is a character used to represent the symbol upon a succeeding reading A Code ID setting is prefixed to the data begin or end transmitted if the feature is s...

Страница 28: ...sum transmission Disable Enable 00 01 Max code length 00 64 00 64 64 Min code length 00 64 00 64 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ff...

Страница 29: ...ck Digit Supplement Digits 2 or 5 or UCC EAN 128 Truncate Leading zero The leading 0 digits of UPCA data characters can be truncated when the function is enabled Program Option Bar Code Option Alphanu...

Страница 30: ...ptional and made as the sum of the numerical value of the data digits Check sum transmission By setting Enable checks sum will be transmitted Program Option Bar Code Option Alphanumeric Entry Read Dis...

Страница 31: ...ding Zero Data Digits 6 Digits Check Digit Supplement Digits 2 or 5 or UCC EAN 128 Truncate Leading zero Refer to Truncate Leading zero of UPCA Expansion The expansion function is used only for UPCE a...

Страница 32: ...setting 00 ffH ASCII code 00 ffH E Insert group selection 00 44 00 44 00 Supplement digits None 2 digits 5 digits UCC EAN 128 Auto detection 00 01 02 03 04 Truncate Leading zero Disable Enable 00 01 E...

Страница 33: ...al Min Max Code Length is in effect The length is defined as to the actual barcode data length to be sent Label with length exceeds these limits will be rejected Make sure that the Minimum length sett...

Страница 34: ...verification Disable Enable 00 01 Check sum transmission Disable Enable 00 01 Max code length 00 64 00 64 64 Min code length 00 64 00 64 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 0...

Страница 35: ...plement Digits 2 or 5 or UCC EAN 128 ISBN ISSN The ISBN International Standard Book Number and ISSN International Standard Serial Number are two kinds of barcode for book and magazines The ISBN is 10...

Страница 36: ...lphanumeric Entry Code ID setting 00 ffH ASCII code 00 ffH F Insert group selection 00 44 00 44 00 Supplement digits None 2 digits 5 digits UCC EAN 128 Auto detection 00 01 02 03 04 ISBN ISSN conversi...

Страница 37: ...Enable checks sum will be transmitted Max Min code length Refer to Max Min code length of EAN 13 Truncate leading ending Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID sett...

Страница 38: ...0 01 Max code length 00 64 00 64 64 Min code length 00 64 00 64 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting Two characters 00 ffH ASCII code 00 ffH 00 ffH FF Insert...

Страница 39: ...cate Leading zero Refer to Truncate Leading zero of UPCE Expansion Refer to Expansion of UPCE Program Option Bar Code Option Alphanumeric Entry Supplement digits None 2 digits 5 digits UCC EAN 128 Aut...

Страница 40: ...onal and made as the sum module 43 of the numerical value of the data digits Check sum transmission By setting Enable checksum and will be transmitted Option Bar Code Option Alphanumeric Entry Read Di...

Страница 41: ...the labels of the symboblogy will not be readable In particular you can see the same value for both Minimum and Maximum reading length to force the fixed length barcode decoded Truncate leading ending...

Страница 42: ...00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group selection 00 44 00 44 00 Format Standard Ful...

Страница 43: ...Preamble and Prefix When a symbol was decoded without the appended code the data will be transmitted without Code ID and Prefix but the Postamble Suffix codes are appended This function is used when...

Страница 44: ...e as the sum module 10 of the numerical values of all data digits Check sum transmission By setting Enable checksum and will be transmitted Program Option Bar Code Option Alphanumeric Entry Read Disab...

Страница 45: ...leading ending of UPCA Code Id setting Refer to Code ID setting of UPCA Insertion group selection Refer to Insertion group selection of UPCA Program Option Bar Code Option Alphanumeric Entry Max code...

Страница 46: ...Code ID setting 00 ffH ASCII code 00 ffH i Insert group selection 00 44 00 44 00 Exit 46...

Страница 47: ...39 Truncate leading ending Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID setting of UPCA Insertion group selection Refer to Insertion group selection of UPCA Program Option...

Страница 48: ...Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group selection 00 44 00 44 00 Exit 48...

Страница 49: ...g Enable checksum and will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID...

Страница 50: ...le Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH B Insert group selec...

Страница 51: ...ksum Transmission By setting Enable checksum and will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code I...

Страница 52: ...m Transmission Disable Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH...

Страница 53: ...pattern you may select one pair to match your application Start End Transmission Refer to Start End Transmission of Code 39 Program Option Bar Code Option Alphanumeric Entry Insert group selection 00...

Страница 54: ...m is made as the sum module 103 of all data digits Checksum Transmission By setting Enable checksum and will be transmitted Program Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01...

Страница 55: ...C1 and next to be a field separator code as GS 1D16 C1 Datas GS Datas Checksum Append When the function is enabled it won t show the data immediately if scanner read the barcode includes FNC2 code It...

Страница 56: ...15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group selection 00 44 00 44 00 Format Standard UCC EAN 128 00 01 Append Disable Enable 00 01 UCC EAN 128 ID setting 00 ffH ASCII code 00 ffH Fiel...

Страница 57: ...g Enable checksum and will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID...

Страница 58: ...ble Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group select...

Страница 59: ...ransmitted upon your selected checksum verification method Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code Id setting...

Страница 60: ...le Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH O Insert group selec...

Страница 61: ...sum Transmission By setting Enable checksum1 and checksum2 will be transmitted upon your selected checksum verification method Max Min code length Refer to Max Min code length of Code 39 Truncate lead...

Страница 62: ...ble Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group select...

Страница 63: ...Checksum Transmission By setting Enable checksum will be transmitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code...

Страница 64: ...ble Enable 00 01 Max code length 00 64 00 64 00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH Insert group select...

Страница 65: ...mitted Max Min code length Refer to Max Min code length of Code 39 Truncate leading ending Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID setting of UPCA Insertion group sel...

Страница 66: ...00 Min code length 00 64 00 64 00 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH S Insert group selection 00 44 00 44 00 Format Numeric only Ful...

Страница 67: ...9 Truncate leading ending Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID setting of UPCA Insertion group selection Refer to Insertion group selection of UPCA Program Option...

Страница 68: ...Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH i Insert group selection 00 44 00 44 00 Exit 68...

Страница 69: ...er to Code ID setting of UPCA Insertion group selection Refer to Insertion group selection of UPCA UCC EAN 128 emulation Refer to Transmission P89 Code ID transmission must be set as AIM ID enable The...

Страница 70: ...Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH R4 Insert group selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00 01 Exit 70...

Страница 71: ...ending Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID setting of UPCA Insertion group selection Refer to Insertion group selection of UPCA UCC EAN 128 emulation Refer to UC...

Страница 72: ...gth 00 64 00 64 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH RL Insert group selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00...

Страница 73: ...g ending Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID setting of UPCA Insertion group selection Refer to Insertion group selection of UPCA UCC EAN 128 emulation Refer to U...

Страница 74: ...gth 00 64 00 99 01 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH RX Insert group selection 00 44 00 44 00 UCC EAN128 emulation Disable Enable 00...

Страница 75: ...Truncate leading ending Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID setting of UPCA Insertion group selection Refer to Insertion group selection of UPCA Program Option Ba...

Страница 76: ...Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH t Insert group selection 00 44 01 44 00 Exit 76...

Страница 77: ...g ending Refer to Truncate leading ending of UPCA Code Id setting Refer to Code ID setting of UPCA Insertion group selection Refer to Insertion group selection of UPCA Leading A If this function is en...

Страница 78: ...de length 00 64 00 64 09 Truncate leading 0 15 00 15 00 Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 01 ffH p Insert group selection 00 44 00 44 00 Leading A Disable Enable 00 01 Ex...

Страница 79: ...Refer to Code ID setting of UPCA Insertion group selection Refer to Insertion group selection of UPCA Program Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Truncate leading 0 15...

Страница 80: ...Refer to Code ID setting of UPCA Insertion group selection Refer to Insertion group selection of UPCA Option Bar Code Option Alphanumeric Entry Read Disable Enable 00 01 Truncate leading 0 15 00 15 00...

Страница 81: ...ostamble for all symbologies In this example you are sending a symbol as a prefix for all symbologies Steps 1 Scan Programming and Prefix characters setting barcode 2 Use the ASCII code table to find...

Страница 82: ...ers 00 00 ffH ASCII code Insert G1 characters setting None 1 22 characters 00 00 ffH ASCII code Insert G2 characters setting None 1 22 characters 00 00 ffH ASCII code Insert G3 characters setting None...

Страница 83: ...3 Scan 4 1 and 4 2 from the barcode on the fold out back page 4 Scan Finish from the barcode on the fold out page 5 Repeat the same procedure in Insert G2 characters setting 6 Scan Exit barcode 7 Ins...

Страница 84: ...Insert G3 characters setting None 1 22 characters 00 00 ffH ASCII code Insert G4 characters setting None 1 22 characters 00 00 ffH ASCII code Exit 84...

Страница 85: ...symbol The position default value is 00 to indicate no character insertion Beside make sure insertion positions are not greater than the symbols otherwise the insertion data is not effective Code ID...

Страница 86: ...0 64 00 Insert data group 2 position 00 64 00 no insertion 00 64 00 Insert data group 3 position 00 64 00 no insertion 00 64 00 Insert data group 4 position 00 64 00 no insertion 00 64 00 Code ID posi...

Страница 87: ...Leading Ending Digits And the length is a number with two digits Code name transmission This function is to show unknown barcode symbologies that include all readable symbologies of the scanner When...

Страница 88: ...ode name transmission Disable Enable 00 01 Case conversion Disable Upper case Lower case For barcode data only 00 01 02 Exit Format of barcode data transmission Prefix Name Preamble ID Code Length Bar...

Страница 89: ...Test Chart CODABAR PARA CODE 11 PARA CODE 128 PARA CODE 39 PARA CODE 93 PARA EAN 13 PARA 89...

Страница 90: ...PDF 417 STANDRAD 25 PARA CODE 16K EAN 8 PARA INDUSTRIAL 25 PARA UPCE PARA 87549 90...

Страница 91: ...INTERLEAVED 25 PARA MATRIX 25 PARA MSI PLESSEY PARA UPCA PARA UK PLESSEY PARA 91...

Страница 92: ...NQ NAK 6 PgDn F6 ACK SYN 7 F7 BEL ETB 8 Bs F8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US L H 2 3 4 5 6 7 0 SP 0 P p 1...

Страница 93: ...de Unique parameter list If you wish to display the unique parameter setting list scan the unique parameter list bar code System parameter setting list If you wish to display the product information a...

Страница 94: ...to display the firmware version scan the Firmware version list WARNING Default value initialization If you wish to return the ZB 8110 8150 8210 to all the factory default settings scan the Default val...

Страница 95: ...97 0 A 1 B 2 C 3 D 4 E 5 F 6 7 8 Finish 9 95...

Отзывы: