background image

6

2.4

Safety instructions 
for working with 
electrical equipment

The following safety instructions must be observed when:

•  you are working with electrical equipment on the pole access ladder,

•  the pole access ladder is used in the vicinity of electrical units,

•  the pole access ladder is used in the vicinity of overhead power lines.

D

ANGER

D

ANGER

 

OF

 

ELECTRIC

 

SHOCKS

 

WHEN

 

WORKING

 

WITH

 

ELECTRICAL

 

EQUIPMENT

 

ON

 

THE

 

POLE

 

ACCESS

 

LADDER

Electrical equipment may only be used on the pole access ladder under the following conditions:

>  With protective low voltage (48 V). 
>  With protective insulation (separation transformer). 
>  If the equipment is connected via a ground fault circuit interrupter with a residual 

current of max. 30 mA.

D

ANGER

D

ANGER

 

OF

 

ELECTRIC

 

SHOCKS

 

WHEN

 

WORKING

 

IN

 

THE

 

VICINITY

 

OF

 

CURRENT

-

BEARING

 

UNITS

Pole access ladders may only be used in the vicinity of such units if the following conditions are met:

>  The unit must be disconnected and secured against being switched back on.
>  The section of the unit in question must be de-energised.
>  The section of the unit must be earthed by means of an earthing strap. 
>  The section of the unit must be insulated against any adjacent current-bearing 

components.

D

ANGER

D

ANGER

 

OF

 

ELECTRIC

 

SHOCKS

 

WHEN

 

WORKING

 

IN

 

THE

 

VICINITY

 

OF

 

OVERHEAD

 

POWER

 

LINES

!

>  When working near overhead power lines, observe the safety clearances listed in 

the table below.

>  When calculating safety clearances, allow for the swinging radius of power lines 

and the movement radius of working personnel. The movement radius includes 
any objects held by personnel.

>  If it is not possible to comply with the safety clearances, have the operating authority 

disconnect the power lines and secure them against being switched back on. 

Rated voltage (V)

Safety clearance (m)

< 1000 V

1.0 m

1 kV – 110 kV

3.0 m

110 kV – 220 kV

4.0 m

220 kV – 380 kV or if the rated 
voltage is not known

5.0 m

Содержание Skymaste Industrial Z600

Страница 1: ...29860 Pole Access Ladder en Z600...

Страница 2: ...2 english 3 11...

Страница 3: ...ns 5 2 4 Safety instructions for working with electrical equipment 6 3 Technical description 7 3 1 Scope of delivery 7 3 2 Identification 7 3 3 Technical data 7 4 Assembly 8 4 1 Safety instructions fo...

Страница 4: ...isregarding these warnings may lead to injury or even fatal injury NOTE The word Note warns of the danger of damage to property or the environment Failure to observe these warnings may lead to damage...

Страница 5: ...ccess ladder use in winds of strengths in excess of 12 m s storms and thunderstorms unauthorised modifications or repairs to the pole access ladder use of non original spare parts climbing the pole ac...

Страница 6: ...ed in the vicinity of such units if the following conditions are met The unit must be disconnected and secured against being switched back on The section of the unit in question must be de energised T...

Страница 7: ...ied see the type plate The type plates are attached to the ladder stiles 3 3 Technical data The maximum height and weight vary according to the scope of the order See the order confirmation for custom...

Страница 8: ...5 1 1 General safety instructions on use Before using the product check the following Have all parts included in the scope of delivery been fitted Is the pole access ladder standing in vertical posit...

Страница 9: ...ty device when exiting the system at the top end of the ladder 5 2 Use 6 Dismantling storage and transport 6 1 Dismantling To dismantle the product follow the instructions for assembly in reverse orde...

Страница 10: ...n plate Order No 891209 or 828384 must be attached to the product The month and year in which the next inspection is due must be clearly legible for users of the equipment Inspection must cover the fo...

Страница 11: ...11 2 2 1 1 1 A 41916 Aufbau...

Страница 12: ...12 2 2 1 2 LCS 1 1 2 2 optional safety measures...

Страница 13: ...13 3 1 ZAST OPTIFLEX R4 4 1 2 B A B 41917...

Страница 14: ...14 5 1 2 2 1 3 2 1 B B...

Страница 15: ...15 6 1 ZAST OPTIFLEX R4 7 1 2 B C C 41918...

Страница 16: ...16 8 1 2 C C 1 2 9 ZAST OPTIFLEX R4 1 2 3...

Страница 17: ...17 Max 150 kg Verwenden...

Страница 18: ...ZARGES GmbH Postfach 16 30 82360 Weilheim Tel 49 8 81 68 71 00 Fax 49 8 81 68 75 00 E Mail zarges zarges de Internet http www zarges de 2010 by Zarges GmbH 05 2010...

Отзывы: