8
Screen:
Course of action:
1)
Select a specific character and the axis for which we intend to declare target coordinates, by pressing
an appropriate key included in the directional keypad (see Fig. 1).
o
The entry window dedicated to the selected axis of travel will be displayed.
2)
Enter the required value of coordinate, using the numeric keypad (
[DEL]
– Deletes the entered
character;
[ESC]
– Cancels the option of entering a value).
3)
Accept the entered value, by pressing
[ENT]
.
4)
Declaration of movement for another axis – go back to item 1.
5)
Activate/Deactivate the Ignore Short Circuit function by pressing the
[IZR]
button (activate this
functions, if it is necessary to ignore the contact between the working bit of the machine with the
table, during travelling, e.g.resulting from measuring the location of a workpiece on the table, using a
sensor).
o
If the Ignore Short Circuit function is on, the following message will appear on the screen: IZR;
6)
Press the
[F1]
“
Move
” button to activate the function
.
o
The machine will travel, according to the set value.
The following keys are available, when this function is carried out:
[STOP]
: Travel is stopped immediately. When the function is paused, the following options for further
actions will appear on the screen:
a.
[Fx]
“
Continue
”
:
Travel will continue;
b.
[Fx]
“
Abort
”
:
Travel will be stopped.
2.1.5
Travel Home
Intended use:
This function enables moving the working bit of the machine home. Once the machine has
reached all limiting switches, the physical coordinates of the machine will be reset (X=0.0; Y=0.0; Z=max height
of crawl corresponding to a particular machine).
Access path:
Manual Mode [R] -> Travel -> Travel to limiting switches
Course of action:
o
The machine will travel, according to the set value.
The following keys are available, when this function is carried out:
[STOP]
: Travel is stopped immediately. When the function is paused, the following options for further
actions will appear on the screen:
a.
[Fx]
“
Continue
”
:
Travel will continue;
b.
[Fx]
“
Abort
”
:
Travel will be stopped.
Attention!!!
1)
It is recommended to carry out a travel home, when:
a)
The machine has been activated for the first time;
b)
The machine has been moved to a different working station;