CLEANING THE INLET HOSE AND THE VALVE FILTER
1
2
3
45°
20°
EMERGENCY DRAIN
If the appliance cannot drain the water, carry out
the same procedure, described in 'Cleaning the
drain pump' paragraph. If necessary, clean the
pump.
When you drain the water with the emergency drain
procedure, you must activate the drain system
again:
1. Put 2 litres of water in the main wash
compartment of the detergent dispenser.
2. Start the programme to drain the water.
FROST PRECAUTIONS
If the appliance is installed in an area where the
temperature can reach values around 0° C or drop
below, remove the remaining water from the inlet
hose and the drain pump.
1. Disconnect the mains plug from the mains
socket.
2. Close the water tap.
3. Put the two ends of the inlet hose in a
container and let the water flow out of the
hose.
4. Empty the drain pump. Refer to the emergency
drain procedure.
5. When the drain pump is empty, install the inlet
hose again.
WARNING! Make sure that the
temperature is higher than 0 °C before
you use the appliance again.
The manufacturer is not responsible
for damages caused by low
temperatures.
TROUBLESHOOTING
WARNING! Refer to Safety chapters.
INTRODUCTION
The appliance does not start or it stops during operation.