CLEANING THE INLET HOSE AND THE VALVE FILTER
1
2
3
1
2
3
45°
20°
4
FROST PRECAUTIONS
If the appliance is installed in an area where the
temperature can be less than 0 °C, remove the
remaining water from the inlet hose and the drain
pump.
Do this procedure also when you want
to do the emergency drain.
1. Disconnect the mains plug from the mains
socket.
2. Remove the water inlet hose.
3. Remove the drain hose from the rear support
and unhook it from sink or spigot.
4. Put the ends of the drain and inlet hose in a
container. Let the water flow out of the hoses.
5. When no more water flows, install the inlet
hose and the drain hose again.
WARNING! Make sure that the
temperature is more than 0 °C before
you use the appliance again. The
manufacturer is not responsible for
damages caused by low temperatures.
TROUBLESHOOTING
WARNING! Refer to Safety chapters.
INTRODUCTION
The appliance does not start or it stops during
operation.
First try to find a solution to the problem (refer to
the table). If the problem persists, contact the
Authorised Service Centre.
With some problems, the acoustic signals
operate and the display shows an alarm
code:
•
- The appliance does not fill with water
properly. Start the appliance again by pressing
Start/Pause button. After 10 seconds the door
will be unlocked.
•
- The appliance does not drain the water.
•
- The appliance door is open or not
closed correctly. Please check the door!
•
- The mains supply is unstable. Wait until
the mains supply is stable.
WARNING! Deactivate the appliance
before you do the checks.