H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05
V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total power
on the rating plate.
CONNECTING THE TERMINAL BOARD
The appliance has a six-pole terminal board. The
jumpers (bridges) are set for operation on a 400 V
three-phase with a neutral wire.
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
1
2
3
4
5
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange the
jumpers on the terminal board (refer to the
connection diagram below). Connect the ground
cable to the terminal. After you connect the supply
cable to the terminal board, attach it with a junction
clamp.
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
230V 3~
230V 1~
400V 2N~
400V 3N~
L1
L1
N
L2
L1
N
N
L2
L3
L1 L2 L3
PE
PE
PE
PE
ENERGY EFFICIENCY
PRODUCT FICHE AND INFORMATION ACCORDING TO EU 65-66/2014
Supplier's name
Zanussi
Model identification
ZOU10411XU
Energy Efficiency Index
94.9
Energy efficiency class
A
Energy consumption with a standard load, conventional
mode
0.75 kWh/cycle
Number of cavities
1
Heat source
Electricity
Volume
56 l
Type of oven
Built-Under Oven
Mass
25.6 kg
EN 60350-1 - Household electric cooking
appliances - Part 1: Ranges, ovens, steam ovens
and grills - Methods for measuring performance.
ENERGY SAVING
The oven contains features which help
you save energy during everyday
cooking.
17
Содержание ZOU10411XU
Страница 1: ...GETTING STARTED EASY User Manual ZOU10411XU EN User Manual Oven ...
Страница 19: ...19 ...
Страница 20: ...WWW ZANUSSI COM SHOP 867348356 A 442018 ...