16
Before the appliance is connected:
1) check that the main fuse and the domestic installation
can support the load;
2) check that the power supply is properly earthed in
compliance with the current rules;
3) check the socket or the double pole switch used for
the electrical connection can be easily reached with
the appliance built in the forniture unit.
This appliance is supplied without connection cable. A
suitable one must be fitted, in compliance with the
electric supply rate. Only the following cable types must
be used: H07 RN-F, H05 RN-F, H05 RR-F, H05 VV-F,
H05 V2V2-F (T90), H05 BB-F. A suitable plug, able to
carry the load specified on the rating plate, must be
fitted to the cable. The plug has to be fitted in a proper
socket.
If connecting the appliance directly to the electric
system, a double pole switch must be installed between
the appliance and the electricity supply, with a minimum
gap of 3 mm. between the switch contacts and of a
type suitable for the required load in compliance with
the current rules. The earth wire must not be interrupted
by the double switch pole.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature 50 °C higher
than the room temperature.
After the connection is carried out, test the heating
elements for about 3 minutes.
Connection to terminal block
This appliance is provided with a 6 poles terminal block
(Fig. 13) set to operate with a 400 V three-phase
electrical supply with neutral wire.
To adapt the the terminal block to a different electrical
supply, carry out the connection as shown in Fig. 14.
The earth wire must be connected to terminal marked
. Once the connection is carried out, fit the cable
into the the cable clamp.
Electrical connection with the
hob
This oven can be connected to hobs indicated in the
"Technical Assistance" section. The socket for
connecting the hob is located at the top of the oven
cabinet. The hobs come complete with connecting leads
for the hot plates/heat areas and ground cable; these
leads feature plug-in connectors. Connection of the hob
to the oven is carried out by plugging-in these
connectors to the corresponding oven socket.
The plug-to-socket connection design is such as to
prevent possible wrong plugging-ins.
The manufacturer disclaims any
responsability should all the safety
measures not be carried out.
Electrical connection
FO 0584
Fig. 14
FO 0330
Fig. 13
230V 3~
1 2 3 4 5
L1 L2 L3 PE
230V 1~
1 2 3 4 5
L1 N PE
400V 2N~
1 2 3 4 5
L1 L2 N PE
400V 3N~
1 2 3 4 5
L1 L2 L3 N PE