Technical data
Dimensions of the recess
Height
mm 600
Width
mm 560
Depth
mm 550
Oven
Height
mm 335
Width
mm 395
Depth
mm 400
Oven capacity
53 l
This appliance can be connected to the below listed
ceramic hobs:
Type:
ZVD 868
(with 2 double-circuit cooking zones)
Maximum power absorbed:
7,6 kW
Power supply voltage
(50 Hz) 230 V
Type: ZK 630 L - ZK 630 F
(with 2 double-circuit cooking zones)
Maximum power absorbed
7,6 kW
Power supply voltage
(50 Hz) 230 V
Type: ZC 6695
(with 1 double-circuit cooking zone)
Maximum power absorbed
6,4 kW
Power supply voltage
(50 Hz) 230 V
Type: ZC 6675
(without double-circuit cooking zone)
Maximum power absorbed
5,8 kW
Power supply voltage
(50 Hz) 230 V
Maximum Total Power Rate
Oven + ceramic hob
9,675 kW
Heating element ratings
Bottom heating element
1000 W
Top Heating element
800 W
Full oven (Top+Bottom)
1800 W
Fan cooking
2000 W
Grill
1650 W
Oven light
25 W
Hot air fan motor
25 W
Cooling fan motor
25 W
Total rating
2075 W
Operating voltage (50 Hz)
230 V
Instructions for the Installer
The instructions given below are designed
specifically for a qualified installer and should
aid him or her to perform all installation,
adjustment, and maintenance operations with
absolute precision and in compliance with all
current legislation and regulations. We
strongly recommend that all operations for
the installation of your cooker be carryed out
by Qualified Personnel in accordance with
existing rules and regulations.
Electrical connection
Prior to making the electrical connection, make sure that:
— the protection fuse and the domestic wiring
system are suitable to carry the total electric load of the
oven (see rating plate);
— your domestic wiring system has an efficient
earth connection in compliance with rules and laws in
force;
— the wall socket or the omnipole switch used for
the electrical connection can easily be reached after the
oven is built in.
This appliance is delivered without an electric supply cable,
therefore, you will have to fit to it a supply cable with standard
plug, suitable for the total electric load shown on the rating plate.
The plug is to be inserted into a suitable wall socket. If you
require a direct connection to the electric network (mains), it will
be necessary to fit between the appliance and the mains an
omnipole switch, with a minimum gap between contacts of 3
mm, suitable for the required load and in compliance with rules
in force. The green & yellow ground wire must not be interrupted
by the switch, and should be 2-3 cm longer than the phase and
neutral wires. The supply cable must in all cases be laid out in
such a way as to ensure that it does not reach at any given
point a temperature 50°C higher than the ambient temperature.
Suitable power supply cables are the following types,
considering the respective necessary section of cable: H07 RN-
F, H05 RN-F, H05 RR-F, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.