Cabinet minimum
height (Cabinet under
the worktop minimum
height)
590 (600) mm
Cabinet width
560 mm
Cabinet depth
550 (550) mm
Height of the front of
the appliance
598 mm
Height of the back of
the appliance
579 mm
Width of the front of
the appliance
594 mm
Width of the back of
the appliance
558 mm
Depth of the appliance
561 mm
Built in depth of the
appliance
540 mm
Depth with open door
1007 mm
Ventilation opening
minimum size. Opening
placed on the bottom
rear side
560x20 mm
Mains supply cable
length. Cable is placed
in the right corner of
the back side
1100 mm
Mounting screws
4x25 mm
ELECTRICAL CONNECTION
WARNING! Risk of fire and electric
shock.
• All electrical connections should be made by a
qualified electrician.
• The appliance must be earthed.
• Make sure that the parameters on the rating
plate are compatible with the electrical ratings
of the mains power supply.
• Always use a correctly installed shockproof
socket.
• Do not use multi-plug adapters and extension
cables.
• Make sure not to cause damage to the mains
plug and to the mains cable. Should the mains
cable need to be replaced, this must be carried
out by our Authorised Service Centre.
• Do not let mains cables touch or come near the
appliance door or the niche below the
appliance, especially when it operates or the
door is hot.
• The shock protection of live and insulated parts
must be fastened in such a way that it cannot be
removed without tools.
• Connect the mains plug to the mains socket
only at the end of the installation. Make sure that
there is access to the mains plug after the
installation.
• If the mains socket is loose, do not connect the
mains plug.
• Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
• Use only correct isolation devices: line
protecting cut-outs, fuses (screw type fuses
removed from the holder), earth leakage trips
and contactors.
• The electrical installation must have an isolation
device which lets you disconnect the appliance
from the mains at all poles. The isolation device
must have a contact opening width of minimum
3 mm.
• This appliance is supplied with a main plug and
a main cable.
Cable types applicable for installation or replace-
ment for Europe:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F,
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total power
on the rating plate. You can also refer to the table:
Total power (W)
Section of the cable
(mm²)
maximum 1380
3x0.75
maximum 2300
3x1
maximum 3680
3x1.5
The earth cord (green / yellow cable) must be 2 cm
longer than the brown phase and blue neutral
cables.
USE
WARNING! Risk of injury, burns and
electric shock or explosion.
4