8.
Turn the gas oven control knob from 240 to
minimum.
Control the flame. If the flame goes out, do the
procedure from point 1 to point 8 again. There
must be a small regular flame on the gas oven
burner crown.
The manufacturer objects liability if you
do not obey to this safety measures.
Building In
Conditions for building-in:
• Only set up the appliance in a kitchen or in a
kitchen-dining room.
• Do not set up the appliance in a bathroom or
a bedroom.
• You can install the appliance "built-in" or
"built-under":
570
594
590
560
540
20
2
130cm²
min.
550mm
110mm
580mm
560-570mm
65cm²
x2
560-570mm
593mm
min. 4mm
65cm²
x2
110mm
min.
550mm
130cm²
• The related illustrations show the necessary
dimensions of the oven and the cabinet (in
millimetres).
• The dimensions of the built-in cabinet must
agree with the related illustrations.
• There must be a minimum clearance of 4 mm
between the top surface of the appliance and
the inner top of the cabinet.
• When you install the appliance "built-under"
(below a hob), install the hob before the oven
unit.
• The materials must be resistant to a tempera-
ture increase of minimum 60 °C above the
ambient temperature.
17