38
1
Safety Instructions for the Installer
•
A device must be provided in the electrical installation which allows the
appliance to be disconnected from the mains at all poles with a contact
opening width of at least 3 mm.
Suitable isolation devices include line protecting cut-outs, fuses (screw
type fuses are to be removed from the holder), earth leakage trips and
contactors.
•
In respect of fire protection, this appliance corresponds to EN 60 335-2-6.
This type of appliance may be installed with a high cupboard or wall on
one side.
•
Drawers may not be fitted underneath the hob.
•
The installation must guarantee shock protection.
•
The kitchen unit in which the appliance is fitted must satisfy the stability
requirements of DIN 68930.
•
For protection against moisture, all cut surfaces are to be sealed with a
suitable sealant.
•
On tiled work surfaces, the joints in the area where the hob sits must be
completely filled with grout.
•
On natural, artificial stone, or ceramic tops, the snap action springs must
be bonded in place with a suitable artificial resin or mixed adhesive.
•
Ensure that the seal is correctly seated against the work surface without
any gaps. Additional silicon sealant must not be applied; this would make
removal more difficult when servicing.
•
The hob must be pressed out from below when removed.
Electrical Connection
Before connecting, check that the nominal voltage of the appliance, that is
the voltage stated on the rating plate, corresponds to the available supply
voltage. The rating plate is located on the lower casing of the hob.
The heating element voltage is AC230V~. The appliance also works per-
fectly on older networks with AC220V~.
The hob is to be connected to the mains using a device that allows the ap-
pliance to be disconnected from the mains at all poles with a contact open-
ing width of at least 3 mm, eg. automatic line protecting cut-out,earth
leakage tripsorfuse.
A type H05VV-F cable or one with a higher grade must be used as the mains
connecting cable.
The connection must be carried out as shown in the diagram. The connect-
ing links should be fitted according to the appropriate connection diagram.
The earth lead is connected to terminal
E
. The earth lead must be longer
than leads carrying electric current.
Содержание ZKF 650 LX
Страница 19: ...40 Rating Plate...
Страница 21: ...84 Montage Assembly Montage Montage...
Страница 22: ...85...
Страница 23: ...86...
Страница 24: ......