INSTALLING THE COOKER HOOD 

 

Please ensure that when the appliance 
is installed it is easily accessible to an 
engineer in the event of a breakdown.

 

 
All installation must comply with the 
local authorities requirements for 
the discharge of exhaust air. 
 

          Incorrect installation may affect the  
          safety of this cooker hood. 
 

Installation Requirements

 

Before installation, check that the  
wall to which the cooker hood is to  
be fitted for electricity cables and  
water and gas pipes. 
 

This cooker hood is designed to be fixed to 
any rigid vertical surface over a cooking 
area, and can be used in the extraction 
(ducted to the outside) or re-circulation 
(internal recycling) mode. 
 
The installation work must be carried out 
by a qualified electrician or competent 
person. 
The manufacturer declines any 
responsibility for damages due to incorrect 
installation of the cooker hood or if the 
cooker hood is not installed in compliance 
with relevant regulations controlling this 
type of installation. 
 
This appliance can be used in either a 
ducting or filtering mode. 

Ducting

 (fig.1) – Cooking vapours and/or 

odours are passed straight outside (ceiling 
and/or wall) via a disposal duct, using the 
holes that are on the top and/or the back 
of the appliance. 

Filtering

 (fig.2) – Cooking vapours and/or 

odours are removed from the air by 2 
charcoal filters and the air is then re-
circulated around the room from the front 
vents. 
ATTENTION: For the filtering option it is 
absolutely necessary to use the charcoal 
filters but not for the ducting option. 

2

 

 

Charcoal filters are available from your 
local Zanussi Service Force Centre:  
Part No. 942 640 157

Содержание ZHC72X

Страница 1: ...OPERATING AND INSTALLATION INSTRUCTIONS ZANUSSI ZHC72X COOKER HOOD ...

Страница 2: ...odify this product in any way When installed between adjoining wall cabinets the cabinets must not overhang the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type If other types of flue or appliances are fitted ensure that there is an adequate supply of air to the room When t...

Страница 3: ... Appliance 4 Operating Instructions 4 Maintenance and Cleaning 5 Something Not Working 6 Service and Spare Parts 6 Customer Care Department 6 Guarantee Conditions 7 For the Installer Technical Information 8 Electrical Connections 8 Installing the Cooker Hood 9 ...

Страница 4: ...t steam To obtain the best performance it is advisable to switch on the hood a few minutes before you start cooking and leave it running for approximately 15 minutes after you finish cooking Cooker Hood Controls A Light switch B On Off switch and first motor speed C Second speed D Third speed E Warning light indicates motor operation ...

Страница 5: ...le by following the instructions and lifting the two metallic stops P If you are using the hood in the re circulation mode you will need to remove the charcoal filter to access the anti grease filters WARNING There is a third metallic filter not visible which can be accessed through opening R External Cleaning Any fat deposits should be removed regularly at least every two months Avoid using abras...

Страница 6: ... the device to reset If after all these checks the problem persists contact your local Service Force Centre quoting the model number and serial number Please note that it will be necessary to provide proof of purchase for any in guarantee calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical...

Страница 7: ... any light bulbs or removable parts of glass or plastic Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are the subject of rental agreements Products of Zanussi manufacture which were not marketed by Zanussi Ltd This guarantee is in addition to your...

Страница 8: ...odifications EEC directive 73 23 Low Voltage and any subsequent modifications ELECTRICAL CONNECTION This appliance must be earthed Electrical Requirements Any permanent electrical installation must comply with the latest I E E Regulations and local Electricity Board Regulations For your own safety this should be undertaken by a qualified electrician e g your local Electricity Board or a contractor...

Страница 9: ...by a qualified electrician or competent person The manufacturer declines any responsibility for damages due to incorrect installation of the cooker hood or if the cooker hood is not installed in compliance with relevant regulations controlling this type of installation This appliance can be used in either a ducting or filtering mode Ducting fig 1 Cooking vapours and or odours are passed straight o...

Страница 10: ...off using the caps supplied Wall Fitting Fix the telescopic part A with some adhesive tape W so that it cannot slip out fig 5 Fix the lower part to the upper part of the hood by using the screws supplied fig 5 5 Using the drilling template fit two of the screw anchors supplied to the wall corresponding to holes B fig 6 Insert two of the screws supplied and hook the hood in place using the holes B ...

Страница 11: ...s remembering that you have to slightly lift the smaller pipe the lower one insert the pipes from the front expanding slightly with your hands so that they can be hooked onto the two brackets Fix the pipes to the brackets using screws G and H 7 Wall cupboard fitting Make four holes in the bottom of the wall cupboard and if operating the hood in the ducting mode cut the air venting hole If the hood...

Страница 12: ...rill two holes in the marked position and insert the screw anchors Fix the lower part by using the 6 screws supplied fig 9 Remove the adhesive tape from the telescopic part and pull it downwards until it touches the hob Make the electrical connection 9 IMPORTANT Check the position of screw M fig 10 Ducting The screw s must be completely screwed in Filtering The screw s must not be screwed in so th...

Страница 13: ...13 ...

Страница 14: ...14 ...

Страница 15: ...15 ...

Страница 16: ... Electrolux Household Appliances Limited 2000 ...

Отзывы: