background image

INSTALLATION INSTRUCTIONS

13

The  versatility  of  the  ducting  fan  unit  on  this  hood
enables it to be installed in one of four different ways:
-

Air outlet directed upwards (re-circulation fitting
only).

-

Air  outlet  directed  towards  the  wall  (ducting
fitting only).

-

Air  outlet  directed  to  the  right  or  left  (ducting
fitting only).For correct installation of the hood,
please proceed in the following stages:

Selection of the type of installation

Installation of the hood canopy C

Installation of the chimney A

Ducting or re-circulation fitting

Electrical connection and testing

Selecting the type of installation

-

Air discharge towards the top
In this case the hood can be used in filter mode

-

Air discharge towards the wall
In this case the hood can only be used in suction
mode.

-

Side air discharge, Lh or Rh.
In this case the hood can only be used in suction
mode.

G

S07_03

S07_30

R

W

W

R

Содержание ZHC 95 ALU

Страница 1: ...COOKER HOOD ZHC 95 ALU INSTRUCTION BOOKLET ...

Страница 2: ...dify this product in any way When installed between adjoining wall cabinets the cabinets must not overhang the hob If the room where the hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type If other types of flue or appliances are fitted ensure that there is an adequate supply of air to the room When th...

Страница 3: ...nstructions 4 Maintenance and Cleaning 5 Something Not Working 6 Service and Spare Parts 6 Customer Care Department 6 Service Force Centres 7 Guarantee Conditions 9 CONTENTS 3 For the Installer Technical Information 10 Electrical Connections 10 Installing the Cooker Hood 11 ...

Страница 4: ...l not extract steam To obtain the best performance it is advisable to switch on the hood a few minutes before you start cooking and leave it running for approximately 15 minutes after you finish cooking Cooker Hood Controls L Light switch V1 On Off switch and first motor speed V2 Second speed V3 Third speed 4 V1 V2 V3 L ...

Страница 5: ... filters and then the carbon filters push inwards on the two retaining clips G1 and disengage the security fixing and remove Light The light consists of 2 x 20W halogen spotlights To replace the lights remove the two screws that lock the metal ring in place Take the spotlight out of the holder by pulling gently When replacing ensure that the screws are firmly inserted back in place 5 S36_31 The co...

Страница 6: ...clean Is the kitchen adequately vented to allow the entry of fresh air If set up for re circulation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The cooker hood has switched off during operation Has the safety cut out tripped Turn off the hob and wait for the device to reset SERVICE AND SPARE PARTS If you require an e...

Страница 7: ...7 ...

Страница 8: ...8 ...

Страница 9: ...of any light bulbs or removable parts of glass or plastic Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are the subject of rental agreements Products of Zanussi manufacture which were not marketed by Zanussi This guarantee is in addition to your s...

Страница 10: ...lectrical Requirements Any permanent electrical installation must comply with the latest I E E Regulations and local Electricity Board Regulations For your own safety this should be undertaken by a qualified electrician e g your local Electricity Board or a contractor who is registered with the National Inspection Council for Electrical Installation Contracting NICEIC Electrical Connection Before ...

Страница 11: ...recycling mode The installation work must be carried out by a qualified electrician or competent person The manufacturer declines any responsibility for damages due to incorrect installation of the cooker hood or if the cooker hood is not installed in compliance with relevant regulations controlling this type of installation Before unpacking the cooker hood position the carton with the arrows poin...

Страница 12: ...overhang the hob and the distance between the underside of the cabinet and the worktop must be 450mm If the height of the wall cabinet is less than 450mm a gap of 50mm must be maintained either side of the hob This cooker hood must not be installed above a cooking appliance with a high level grill This appliance can be used in either a ducting or filtering mode Ducting Cooking vapours and or odour...

Страница 13: ...lation of the hood please proceed in the following stages Selection of the type of installation Installation of the hood canopy C Installation of the chimney A Ducting or re circulation fitting Electrical connection and testing Selecting the type of installation Air discharge towards the top In this case the hood can be used in filter mode Air discharge towards the wall In this case the hood can o...

Страница 14: ...easuring the extension Z of the chimney required for installation plus 18 mm X Z 25 7 Using a Ø8 mm drill bit drill the points marked in this way b When installed with the air outlet directed towards the wall a it will be necessary to drill an air ducting opening measuring Ø120 mm according to the diameter of the flange F provided Fitting the fixing elements a Insert the rawl plugs into holes 1 an...

Страница 15: ... the rear of the hood which can be used to adjust its position as follows Turn the screws L until the position of screws N coincides with the lower access holes Turn the screws N to adjust the vertical and horizontal position of the hood Lock the screws L to fasten the hood against the wall Insert the plugs T provided in the holes giving access to screws N Installation of the chimney A No matter w...

Страница 16: ...on and position of the ducting fan unit a The hood is normally supplied with the air outlet directed towards the wall if it is to be installed with the air outlet directed to the right or left it will be necessary to change the direction of the ducting fan unit proceeding as follows Unscrew the screws U Turn the ducting fan unit 60 to the right or left Replace the screws U b The ducting fan unit a...

Страница 17: ...the two parts of the chimney and pull the inner section I almost all the way out Remove the protective film P b Rest the lower section of the chimney in its housing on the top of the hood canopy Lower the ducting fan unit until it reaches the wall bracket S and fix it using the screw H provided Fit the cover D provided on the wall bracket S c Fix the chimney to the hood canopy C using the four scr...

Страница 18: ...nside the hood canopy after connection to the power supply Connection to power supply and checking of good working order 1 It is absolutely necessary to follow the warnings 3 2 3 3 and 3 4 of paragraph 3 concerning safety measures 2 Loosen the two locking screws and remove the metal cover Connect the hood connection to the engine connection a Correctly place the connectors under the cover and tigh...

Страница 19: ......

Страница 20: ...4329478 03 010910 Electrolux Household Appliances Limited 2001 ...

Отзывы: