INSTALLATION

This  canopy  hood  is  designed  to  be  fixed  to  any  rigid  vertical  surface,  over  a  gas  or
electric hotplate and can be used either in the extraction mode (ducted to the outside) or
in the recirculation mode (internal recycling).

Safety  warnings

• Before  commencing  the  installation,  consideration  should  be  given  to  the  difficulties

to  be  found  during  installation  and  to  the  bulky  weight  of  the  hood.  The  installation
work  must  be  undertaken  by  a  qualified  and  competent  person  in  conformity  to  the
rules  concerning  the  evacuation  of  contaminated  air.  The  manufacturer  disclaims  all
liability  for  any  damage  or  injury  caused  as  a  result  of  not  following  the  instructions
for  installation  contained  in  the  following  text.

• When used in the extraction mode the cooker hood ducting must not be connected to

a flue which is used for exhausting fumes from appliances supplied with energy other
than  electric  such  as  a  central  heating  flue  or  water  heating  flue.

• When istalled, the hood must be positioned at least 65 cm above a cooking appliance.
• Never  do  flambé  cooking  under  this  cooker  hood.
• Never leave frying pans unattended during use as overheated fats and oils may catch

fire.

• If  the  room  where  the  cooker  hood  is  to  be  used  contains  a  fuel  burning  appliance

such as a central heating boiler then this must be of the room sealed or balanced flue
type.  If  other  types  of  flue  or  appliance  are  fitted  ensure  that  there  is  an  adequate
supply  of  air  into  the  room.  When  the  cooker  hood  is  used  in  conjunction  with  other
appliances supplied with energy other than electric, the negative pressure in the room
must  not  exceed  0,04  mbar  to  prevent  fumes  being  drawn  back  into  the  room  by  the
cooker  hood.

Components

The hood comprises the following (

fig.1

):

• No.1 canopy 

C

 complete with

controls, lighting and ventilator
unit

• No.1 telescopic chimney,

comprising:
No.1 upper chimney element 

S

No.1 lower chimney element 

I

• No.2 directional grills 

G

• No.1 reduction flange Ø 150-120

A

• No.1 valve 

V

 (optional )

• No.1 recirculation spigot 

R

• No.2 additional side recirculation

spigots 

P1

• No.1 additional recirculation

spigot 

P

• No.1 bag containing:

No.2 brackets 2 to fix the
chimney, screws, rawl plugs and
documents.

G

S

I

2

A

R

P1

V

P

C

Fig. 1

Содержание ZHC 929 X

Страница 1: ...ap ZHC 929 X MANUALE DI INSTALLAZIONE USO E MANUTENZIONE INSTALLATION USE AND MAINTENANCE HANDBOOK MANUEL D INSTRUCTIONS POUR L INSTALLATION L EMPLOI ET L ENTRETIEN HANDBUCH FÜR INSTALLATION BEDIENUNG UND WARTUNG INSTRUCTIES VOOR MONTAGE GEBRUIK EN ONDERHOUD ...

Страница 2: ...east 65 cm above a cooking appliance Never do flambé cooking under this cooker hood Never leave frying pans unattended during use as overheated fats and oils may catch fire If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then this must be of the room sealed or balanced flue type If other types of flue or appliance are fitted ensure...

Страница 3: ...st the wall aligning it with the vertical line at a distance X measured as shown in fig 2 equal to the height of the upper chimney element S supplied with the hood The position X may vary according to the various sizes of upper chimney element available d Mark the centres of the keyholes in the bracket on the wall Drilling fixing holes item 1 a Mark a point on the vertical line at a distance from ...

Страница 4: ...umination motor and speed work properly Ducting or Recirculation fitting Ducting fitting The hood can be ducted to the outside using either rigid or flexible ducting Ø 120 or 150 mm the choice of which is left to the installer When 120 mm ducting is to be used it will be necessary to install the reduction flange item A on the air outlet fig 5 Cut the additional spigot P in correspondence with outl...

Страница 5: ... the venting grilles until after the chimney has been installed Fitting the telescopic chimney To fit the upper section S first expand the two side pieces slightly hook them behind the brackets 2 and close them together again until they touch Fix the upper section S to the brackets 2 using four of the screws provided in the bag of accessories fig 7 Fit the lower section I as above between the uppe...

Страница 6: ...tended Always ensure that the flame is kept at the correct intensity to prevent the flame from licking round from the bottom of the pan this will save energy and will avoid a dangerous concentration of heat Always ensure that the appliance is used in accordance with the manufacturer s instructions for the removal of contaminated air and odours during cooking Instruction for Use Control panel fig 9...

Страница 7: ...this function does not need to be enabled Resetting the alarm signal To turn the alarm signal off proceed as follows Turn off the Lights T1 and the Suction Motor T2 Press the Speed T4 for at least 3 seconds until the Leds flash in confirmation In any case the saturated filters alarm will only come into operation when the suction motor is turned on ATTENTION There could be a possible fire hazard if...

Страница 8: ...4 for at least 3 seconds until the Leds flash in confirmation In any case the saturated filters alarm will only come into operation when the suction motor is turned on ATTENTION There could be a possible fire hazard if the filters are not replaced according to these instructions Lighting Version with halogen spotlights 90 cm model two 20W halogen spotlights To replace fig 12 Remove the two screws ...

Страница 9: ...conforme à la norme européenne sur la basse tension C E E 73 23 relative à la sécurité électrique et aux normes européennes C E E 89 336 relative à la compatibilité électromagnétique et C E E 93 68 relative au marquage CE Dieses Gerät entspricht den europäischen Niederspannungsrichtlinien 73 23 EWG zur elektrischen Sicherheit den europäischen Richtlinien 89 336 EWG zur elektromagnetischen Verträgl...

Отзывы: