background image

GETTING 
STARTED?

EASY.

User Manual

ZGNN955X

EN User Manual

Hob

GB

IE

Содержание ZGNN955X

Страница 1: ...GETTING STARTED EASY User Manual ZGNN955X EN User Manual Hob GB IE ...

Страница 2: ...ning the use of the appliance in a safe way and understand the hazards involved Children between 3 and 8 years of age and persons with very extensive and complex disabilities shall be kept away from the appliance unless continuously supervised Children of less than 3 years of age should be kept away from the appliance unless continuously supervised Do not let children play with the appliance Keep ...

Страница 3: ... the appliance If the supply cord is damaged it must be replaced by the manufacturer an authorized Service or similarly qualified persons in order to avoid a hazard Where the appliance is directly connected to the power supply an all pole isolating switch with a contact gap is required Complete disconnection in compliance with the conditions specified in overvoltage category III must be guaranteed...

Страница 4: ...orrectly Loose and incorrect electricity mains cable or plug if applicable can make the terminal become too hot Use the correct electricity mains cable Do not let the electricity mains cable tangle Make sure that a shock protection is installed Use the strain relief clamp on the cable Make sure the mains cable or plug if applicable does not touch the hot appliance or hot cookware when you connect ...

Страница 5: ...ap the edges of the appliance This can cause damage to the worktop surface Make sure the flame does not go out when you quickly turn the knob from the maximum to the minimum position Use only the accessories supplied with the appliance Do not install a flame diffuser on the burner The use of a gas cooking appliance results in the production of heat and moisture Provide good ventilation in the room...

Страница 6: ...there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements For appliances installed in the Republic of Ireland please refer to the NSAI Domestic Gas Installation I S 813 Current Editions Table Four Location The hob may be located in a kitchen a kitchen diner or bed sitting room with a volume greater ...

Страница 7: ... pan supports 2 Remove the caps and crowns of the burner 3 With a socket spanner 7 remove the injectors and replace them with the ones which are necessary for the type of gas you use see table in Technical Data chapter 4 Assemble the parts follow the same procedure backwards 5 Attach the label with the new type of gas supply near the gas supply pipe You can find this label in the package supplied ...

Страница 8: ...on the roll of the National Inspection Council for Electrical Installation Contracting NICEIC The manufacturer refuses to be held responsible if these safety measures are not abided by Supply connections This hob has to be connected to 220 240 V 50 60 Hz electricity supply The hob has a terminal block which is marked as follows L Live terminal N Neutral terminal or E Earth terminal Before carrying...

Страница 9: ... 2 cm longer than the live and neutral wire A A B 1 Connect the green and yellow earth wire to the terminal which is marked with the letter E or the earth symbol or coloured green and yellow 2 Connect the blue neutral wire to the terminal which is marked with the letter N or coloured blue 3 Connect the brown live wire to the terminal which is marked with the letter L It must always be connected to...

Страница 10: ...ace POSSIBILITIES FOR INSERTION The panel installed below the hob must be easy to remove and let an easy access in case a technical assistance intervention is necessary Kitchen unit with door or drawer min 6 mm min 30 mm 60 mm min 5 mm max 150 mm A B A Removable panel B Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for s...

Страница 11: ...iliary burner 4 Rapid burner 5 Control knobs CONTROL KNOB Symbol Description no gas supply off position ignition position maximum gas supply Symbol Description minimum gas supply DAILY USE WARNING Refer to Safety chapters BURNER OVERVIEW A Burner cap B Burner crown C Ignition candle D Thermocouple 11 ...

Страница 12: ...ntrol knob counter clockwise to maximum gas supply position and push it down Keep the control knob pushed for equal or less than 10 seconds to let the thermocouple warm up If the burner accidentally goes out turn the control knob to the off position and try to light the burner again after minimum 1 minute The spark generator can start automatically when you switch on the mains after installation o...

Страница 13: ...mall amount of mild detergent for a few minutes before cleaning Use cleaning products designed specifically for cleaning stainless steel in order to protect the steel surfaces Do not use cleaning products containing corrosive chemicals such as chlorides do not clean the surface with disinfectants stain or rust removers and immersion cleaners PAN SUPPORTS The pan supports are not resistant to washi...

Страница 14: ...e spark generator The hob is not connected to an electrical supply or it is con nected incorrectly Check if the hob is correctly connected to the electrical supply The fuse is blown Make sure that the fuse is the cause of the malfunction If the fuse is blown again and again contact a qualified electrician Burner cap and crown are placed incorrectly Place the burner cap and crown correctly The flam...

Страница 15: ...O 03 IT MADE IN ITALY TYPE IP20 0049 A B C A Stick it on Guarantee Card and send this part if applicable B Stick it on Guarantee Card and keep this part if applicable C Stick it on instruction booklet TECHNICAL DATA HOB DIMENSIONS Width 857 mm Depth 520 mm BYPASS DIAMETERS BURNER Ø BYPASS 1 100 mm Multi Crown 57 Rapid 52 Semi rapid 35 Auxiliary 28 15 ...

Страница 16: ... mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK Multi Crown 4 0 1 4 146 Rapid 2 95 0 75 119 Semi rapid 1 85 0 6 92 Auxiliary 1 0 0 33 70 GAS BURNERS FOR LPG G30 G31 28 30 37 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK NOMINAL GAS FLOW g h G30 28 30 mbar G31 37 mbar Multi Crown 3 65 1 4 095 265 261 Rapid 2 8 0 95 86 204 200 Semi rapid 2 0 0 6 71 145 143 Auxiliary 1 0 0 33...

Страница 17: ...f burners Center the pot on the burner When you heat up water use only the amount you need If it is possible always put the lids on the cookware When the liquid starts to boil turn down the flame to barely simmer the liquid If it is possible use a pressure cooker Refer to its user manual ENVIRONMENTAL CONCERNS Recycle materials with the symbol Put the packaging in relevant containers to recycle it...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...WWW ZANUSSI COM SHOP 867356522 B 072020 ...

Отзывы: