Zanussi ZGNN640W Скачать руководство пользователя страница 8

WARNING! Make sure to place the

gasket exactly in the original position.

WARNING! Make sure the flame does

not go out when you quickly turn the

knob from the maximum position to the

minimum position.

ELECTRICAL CONNECTION
• Do not pull the mains cable to disconnect the

appliance. Always pull the mains plug (if

applicable).

• The appliance must not be connected with an

extension cable, an adapter or a multiple socket.

There is a risk of fire.

• Do not let the power cable to heat up to a

temperature of more than 90° C. The cable

should be guided by means of clamps fixed to

the side of the cabinet, in order to avoid any

contact with the appliance beneath the cooktop.

• Make sure that there is access to the mains plug

after the installation.

Electrical Requirements

Permanent electrical installation must agree with

the latest I.E.E. Regulations and local Electricity

Board regulations. For your own safety the

installation must be done by a qualified electrician

(e.g. your local Electricity Board, or a contractor

who is on the roll of the National Inspection Council

for Electrical Installation Contracting [NICEIC]).

The manufacturer refuses to be

held responsible, if these safety

measures are not abided by.

Supply connections

This hob has to be connected to 220-240 V (~

50-60 Hz ) electricity supply.
The hob has a terminal block which is

marked as follows:
• L — Live terminal

• N — Neutral terminal

 or E — Earth terminal

Before carrying out the connection, make sure:
1. The limiter valve and the electrical system can

take the appliance load (see the rating plate)

2. The supply system is equipped with an efficient

earth connection in compliance with the current

standards and regulations

3. The outlet or omnipolar switch used for

connection is easily accessible with the

appliance installed.

The appliance is supplied with a 3 core flexible

power cable with a 3 amp plug. If it is necessary to

change the fuse, use a 3 amp ASTA-approved (BS

1362) fuse.

A

B

C

D

E

A. Green and Yellow

B. 3 amp fuse

C. Brown

D. Cord clamp

E. Blue
The wires in the cord are coloured as follows:

Green and yellow

- Earth

Blue

- Neutral

Brown

- Live

WARNING! A cut off plug inserted

into a 13 amp socket is a serious

shock hazard. Ensure that the cut off

plug is disposed of safely.

REPLACEMENT OF THE CONNECTION

CABLE

The replacement of electric cable must

be carried out exclusively by the

service force centre or by personnel

with similar competencies, in

accordance with the current

regulations.

To replace the connection cable use

only H03V2V2-F T90 or equivalent

type. Make sure that the cable section

is applicable to the voltage load and

the working temperature. The yellow/

green earth wire (B) must be

approximately 2 cm longer than the

live and neutral wire (A).

8

Содержание ZGNN640W

Страница 1: ...GETTING STARTED EASY User Manual ZGNN640W ZGNN640X ZGNT640X EN User Manual Hob GB IE ...

Страница 2: ...ities shall be kept away from the appliance unless continuously supervised Children of less than 3 years of age should be kept away from the appliance unless continuously supervised Do not let children play with the appliance Keep all packaging away from children and dispose of it appropriately Keep children and pets away from the appliance when it operates or when it cools down Accessible parts m...

Страница 3: ...le isolating switch with a contact gap is required Complete disconnection in compliance with the conditions specified in overvoltage category III must be guaranteed The earth cable is excluded from this When you route the mains cable make sure that the cable doesn t come into direct contact for example using insulating sleeving with parts that can reach temperatures of more than 50 C above room te...

Страница 4: ...if applicable does not touch the hot appliance or hot cookware when you connect the appliance to the near sockets Do not use multi plug adapters and extension cables Make sure not to cause damage to the mains plug if applicable or to the mains cable Contact our Authorised Service Centre or an electrician to change a damaged mains cable The shock protection of live and insulated parts must be faste...

Страница 5: ...on the burner The use of a gas cooking appliance results in the production of heat and moisture Provide good ventilation in the room where the appliance is installed Prolonged intensive use of the appliance may call for additional ventilation for example opening of a window or more effective ventilation for example increasing the level of mechanical ventilation where present This appliance is for ...

Страница 6: ... kitchen a kitchen diner or bed sitting room with a volume greater than 20 m but not in a bathroom or shower room The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 400 mm If it is fitted below 400 mm a space of 50 mm must be allowed from the edges of the hob For appliances installed in the Republic of Ireland please refer to NSAI Domestic Ga...

Страница 7: ...s follow the same procedure backwards 5 Attach the label with the new type of gas supply near the gas supply pipe You can find this label in the package supplied with the appliance If the supply gas pressure is changeable or different from the necessary pressure you must fit an applicable pressure adjuster on the gas supply pipe ADJUSTMENT OF MINIMUM LEVEL To adjust the minimum level of the burner...

Страница 8: ...40 V 50 60 Hz electricity supply The hob has a terminal block which is marked as follows L Live terminal N Neutral terminal or E Earth terminal Before carrying out the connection make sure 1 The limiter valve and the electrical system can take the appliance load see the rating plate 2 The supply system is equipped with an efficient earth connection in compliance with the current standards and regu...

Страница 9: ... terminal which is marked with the letter L It must always be connected to the network phase There must be no cut or stray strands of wire present The cord clamp must be correctly attached to the outer sheath ASSEMBLY 1 2 3 min 55 mm min 650 mm 550 mm 2 0 min 100 mm 30 mm 470 mm 2 0 min 600 mm 4 50 mm 400 mm If a furniture unit is installed at a distance of 400 mm above the hob there must be a min...

Страница 10: ...asy to remove and let an easy access in case a technical assistance intervention is necessary Kitchen unit with door or drawer min 6 mm min 30 mm 60 mm min 5 mm max 150 mm A B A Removable panel B Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit 10 ...

Страница 11: ...Semi rapid burner 3 Auxiliary burner 4 Control knobs CONTROL KNOB Symbol Description no gas supply off position ignition position maximum gas supply Symbol Description minimum gas supply DAILY USE WARNING Refer to Safety chapters BURNER OVERVIEW A B D C A Burner cap 11 ...

Страница 12: ...the control knob pushed for equal or less than 10 seconds to let the thermocouple warm up If the burner accidentally goes out turn the control knob to the off position and try to light the burner again after minimum 1 minute The spark generator can start automatically when you switch on the mains after installation or a power cut It is normal The hob is supplied with the progressive valves They ma...

Страница 13: ...you replace the pan supports to prevent the hob top from damage 2 The enamel coating occasionally can have rough edges so be careful when you wash the pan supports by hand and dry them If necessary remove stubborn stains with a paste cleaner 3 After you clean the pan supports make sure that they are in correct positions 4 For the burner to operate correctly make sure that the arms of the pan suppo...

Страница 14: ...ame extinguishes immedi ately after ignition Thermocouple is not heated up sufficiently After lightning the flame keep the knob pushed for equal or less than 10 seconds The flame ring is uneven Burner crown is blocked with food residues Make sure that the injector is not blocked and the burner crown is clean IF YOU CANNOT FIND A SOLUTION If you cannot find a solution to the problem yourself contac...

Страница 15: ...NO SER NO 03 IT MADE IN ITALY TYPE IP20 0049 A B C A Stick it on Guarantee Card and send this part if applicable B Stick it on Guarantee Card and keep this part if applicable C Stick it on instruction booklet TECHNICAL DATA HOB DIMENSIONS Width 594 mm Depth 510 mm BYPASS DIAMETERS BURNER Ø BYPASS 1 100 mm Rapid 42 Semi rapid 32 Auxiliary 28 15 ...

Страница 16: ...FOR NATURAL GAS G20 20 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK Rapid 3 0 0 75 119 Semi rapid 2 0 0 45 96 Auxiliary 1 0 0 33 70 GAS BURNERS FOR LPG G30 G31 28 30 37 mbar BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK NOMINAL GAS FLOW g h G30 28 30 mbar G31 37 mbar Rapid 2 8 0 75 86 204 200 Semi rapid 2 0 0 45 71 145 143 Auxiliary 1 0 0 33 50 73 71 ENERGY EFFICIENCY PRODUCT...

Страница 17: ... Before use make sure that the burners and pan supports are assembled correctly Use cookware with diameters applicable to the size of burners Center the pot on the burner When you heat up water use only the amount you need If it is possible always put the lids on the cookware When the liquid starts to boil turn down the flame to barely simmer the liquid If it is possible use a pressure cooker Refe...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...WWW ZANUSSI COM SHOP 867356519 B 512019 ...

Отзывы: