GAS BURNERS FOR LPG G30/G31 30/30 mbar
BURNER
NORMAL POWER
kW
MINIMUM POW-
ER kW
INJECTOR MARK NOMINAL GAS FLOW
g/h
Rapid
2,8
0,75
86
204
Semi-rapid
2,0
0,45
71
145
Auxiliary
1,0
0,33
50
73
ELECTRIC COOKING ZONES SPECIFICATION
Cooking zone
Nominal Power (Max heat setting)
[W]
Cooking zone diameter [mm]
Left rear
1000
145
For optimal cooking results use cookware not larger
than the diameter of the cooking zone.
ENERGY EFFICIENCY
PRODUCT INFORMATION ACCORDING TO EU 66/2014
Model identification
ZGM64300X
Type of hob
Built-in hob
Number of electric cooking zones
1
Heating technology per electric cooking
zone
Solid Hot Plate
Diameter of circular electric cooking
zones (Ø)
Left rear
14.5 cm
Energy consumption per cooking zone
(EC electric cooking)
Left rear
194.9 Wh / kg
Number of gas burners
3
Energy efficiency per gas burner
(EE gas burner)
Right rear - Rapid
59.4%
Left front - Semi-rapid
62.2%
Right front - Auxiliary
not applicable
Energy efficiency for the gas hob
(EE gas hob)
60.8%
Energy consumption of the hob (EC
electric hob)
194.9 Wh / kg
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of energy - General
EN 60350-2 - Household electric cooking appliances - Part 2: Hobs - Methods for measuring
performance
16