POSSIBILITIES FOR INSERTION
The panel installed below the hob must be easy to
remove and let an easy access in case a technical
assistance intervention is necessary.
Kitchen unit with door
min 6 mm
min 20 mm
(max 150 mm)
min 30 mm
60 mm
B
A
A. Removable panel
B. Space for connections
Kitchen unit with oven
The electrical connection of the hob and the oven
must be installed separately for safety reasons and
to let easy remove oven from the unit.
TECHNICAL DATA
HOB DIMENSIONS
Width
580 mm
Depth
500 mm
BYPASS DIAMETERS
BURNER
Ø BYPASS 1/100 mm
Rapid
42
Semi-rapid
32
Auxiliary
28
OTHER TECHNICAL DATA
TOTAL POWER:
Gas original:
G20 (2H) 20 mbar = 6,0 kW
Gas replacement:
G30 (3+) 28-30 mbar = 422 g/h
G31 (3+) 37 mbar = 414 g/h
Electric zones:
1,5 kW
Electric supply:
220-240 V ~ 50/60 Hz
Appliance category:
II2H3+
Gas connection:
G 1/2"
Appliance class:
3